mirror of
https://github.com/CHOMPStation2/CHOMPStation2.git
synced 2025-12-10 10:12:45 +00:00
- First issue is power monitoring consoles showing slightly inaccurate values. The code calculated some sort of level average which resulted in stupid values being reported (like load 500kW available 300kW). This also fixes APC load partially showing as Other load on the console. - Second fixed issue (Fixes #7869) resolved gamebreaking bug that caused total irreversible failure of all powernets if makepowernets() was called. This, for example, includes large enough explosions, via admin command, or few other cases.
156 lines
4.9 KiB
Plaintext
156 lines
4.9 KiB
Plaintext
/datum/powernet
|
|
var/list/cables = list() // all cables & junctions
|
|
var/list/nodes = list() // all connected machines
|
|
|
|
var/load = 0 // the current load on the powernet, increased by each machine at processing
|
|
var/newavail = 0 // what available power was gathered last tick, then becomes...
|
|
var/avail = 0 //...the current available power in the powernet
|
|
var/viewload = 0 // the load as it appears on the power console (gradually updated)
|
|
var/number = 0 // Unused //TODEL
|
|
|
|
var/perapc = 0 // per-apc avilability
|
|
var/perapc_excess = 0
|
|
var/netexcess = 0 // excess power on the powernet (typically avail-load)
|
|
|
|
var/problem = 0 // If this is not 0 there is some sort of issue in the powernet. Monitors will display warnings.
|
|
|
|
/datum/powernet/New()
|
|
powernets += src
|
|
..()
|
|
|
|
/datum/powernet/Del()
|
|
powernets -= src
|
|
..()
|
|
|
|
//Returns the amount of excess power (before refunding to SMESs) from last tick.
|
|
//This is for machines that might adjust their power consumption using this data.
|
|
/datum/powernet/proc/last_surplus()
|
|
return max(avail - load, 0)
|
|
|
|
/datum/powernet/proc/draw_power(var/amount)
|
|
var/draw = between(0, amount, avail - load)
|
|
load += draw
|
|
return draw
|
|
|
|
/datum/powernet/proc/is_empty()
|
|
return !cables.len && !nodes.len
|
|
|
|
//remove a cable from the current powernet
|
|
//if the powernet is then empty, delete it
|
|
//Warning : this proc DON'T check if the cable exists
|
|
/datum/powernet/proc/remove_cable(var/obj/structure/cable/C)
|
|
cables -= C
|
|
C.powernet = null
|
|
if(is_empty())//the powernet is now empty...
|
|
del(src)///... delete it - qdel
|
|
|
|
//add a cable to the current powernet
|
|
//Warning : this proc DON'T check if the cable exists
|
|
/datum/powernet/proc/add_cable(var/obj/structure/cable/C)
|
|
if(C.powernet)// if C already has a powernet...
|
|
if(C.powernet == src)
|
|
return
|
|
else
|
|
C.powernet.remove_cable(C) //..remove it
|
|
C.powernet = src
|
|
cables +=C
|
|
|
|
//remove a power machine from the current powernet
|
|
//if the powernet is then empty, delete it
|
|
//Warning : this proc DON'T check if the machine exists
|
|
/datum/powernet/proc/remove_machine(var/obj/machinery/power/M)
|
|
nodes -=M
|
|
M.powernet = null
|
|
if(is_empty())//the powernet is now empty...
|
|
del(src)///... delete it - qdel
|
|
|
|
|
|
//add a power machine to the current powernet
|
|
//Warning : this proc DON'T check if the machine exists
|
|
/datum/powernet/proc/add_machine(var/obj/machinery/power/M)
|
|
if(M.powernet)// if M already has a powernet...
|
|
if(M.powernet == src)
|
|
return
|
|
else
|
|
M.disconnect_from_network()//..remove it
|
|
M.powernet = src
|
|
nodes[M] = M
|
|
|
|
// Triggers warning for certain amount of ticks
|
|
/datum/powernet/proc/trigger_warning(var/duration_ticks = 20)
|
|
problem = max(duration_ticks, problem)
|
|
|
|
|
|
//handles the power changes in the powernet
|
|
//called every ticks by the powernet controller
|
|
/datum/powernet/proc/reset()
|
|
var/numapc = 0
|
|
|
|
if(problem > 0)
|
|
problem = max(problem - 1, 0)
|
|
|
|
if(nodes && nodes.len) // Added to fix a bad list bug -- TLE
|
|
for(var/obj/machinery/power/terminal/term in nodes)
|
|
if( istype( term.master, /obj/machinery/power/apc ) )
|
|
numapc++
|
|
|
|
netexcess = avail - load
|
|
|
|
if(numapc)
|
|
//very simple load balancing. If there was a net excess this tick then it must have been that some APCs used less than perapc, since perapc*numapc = avail
|
|
//Therefore we can raise the amount of power rationed out to APCs on the assumption that those APCs that used less than perapc will continue to do so.
|
|
//If that assumption fails, then some APCs will miss out on power next tick, however it will be rebalanced for the tick after.
|
|
if (netexcess >= 0)
|
|
perapc_excess += min(netexcess/numapc, (avail - perapc) - perapc_excess)
|
|
else
|
|
perapc_excess = 0
|
|
|
|
perapc = avail/numapc + perapc_excess
|
|
|
|
if(netexcess > 100 && nodes && nodes.len) // if there was excess power last cycle
|
|
for(var/obj/machinery/power/smes/S in nodes) // find the SMESes in the network
|
|
S.restore() // and restore some of the power that was used
|
|
|
|
//updates the viewed load (as seen on power computers)
|
|
viewload = round(load)
|
|
|
|
//reset the powernet
|
|
load = 0
|
|
avail = newavail
|
|
newavail = 0
|
|
|
|
/datum/powernet/proc/get_electrocute_damage()
|
|
switch(avail)
|
|
if (1000000 to INFINITY)
|
|
return min(rand(50,160),rand(50,160))
|
|
if (200000 to 1000000)
|
|
return min(rand(25,80),rand(25,80))
|
|
if (100000 to 200000)//Ave powernet
|
|
return min(rand(20,60),rand(20,60))
|
|
if (50000 to 100000)
|
|
return min(rand(15,40),rand(15,40))
|
|
if (1000 to 50000)
|
|
return min(rand(10,20),rand(10,20))
|
|
else
|
|
return 0
|
|
|
|
////////////////////////////////////////////////
|
|
// Misc.
|
|
///////////////////////////////////////////////
|
|
|
|
|
|
// return a knot cable (O-X) if one is present in the turf
|
|
// null if there's none
|
|
/turf/proc/get_cable_node()
|
|
if(!istype(src, /turf/simulated/floor))
|
|
return null
|
|
for(var/obj/structure/cable/C in src)
|
|
if(C.d1 == 0)
|
|
return C
|
|
return null
|
|
|
|
/area/proc/get_apc()
|
|
for(var/area/RA in src.related)
|
|
var/obj/machinery/power/apc/FINDME = locate() in RA
|
|
if (FINDME)
|
|
return FINDME |