- Completely reworks the powernet sensor system that i created. - Code mostly refactored to nice properly commented one. - Sensors now have (currently unused) proc for returning HTML encoded string (it's there if someone needs it) and (newly added) proc that returns assoc list of data. - Thanks to previous, the console has been fully reworked to utilize NanoUI. - This addresses most issues with old UI which was harder to use and somewhat buggy at specific situations (such as, showing lower load than suposed)
194 lines
6.6 KiB
Plaintext
194 lines
6.6 KiB
Plaintext
// POWERNET SENSOR
|
||
//
|
||
// Last Change 31.12.2014 by Atlantis
|
||
//
|
||
// Powernet sensors are devices which relay information about connected powernet. This information may be relayed
|
||
// via two procs. Proc return_reading_text will return fully HTML styled string which contains all information. This
|
||
// may be used in PDAs or similar applications. Second proc, return_reading_data will return list containing needed data.
|
||
// This is used in NanoUI, for example.
|
||
|
||
/obj/machinery/power/sensor
|
||
name = "Powernet Sensor"
|
||
desc = "Small machine which transmits data about specific powernet"
|
||
anchored = 1
|
||
density = 0
|
||
layer = 2.46 // Above cables, but should be below floors.
|
||
icon = 'icons/obj/objects.dmi'
|
||
icon_state = "floor_beacon" // If anyone wants to make better sprite, feel free to do so without asking me.
|
||
|
||
var/name_tag = "#UNKN#" // ID tag displayed in list of powernet sensors. Each sensor should have it's own tag!
|
||
var/long_range = 0 // If 1, sensor reading will show on all computers, regardless of Zlevel
|
||
|
||
// Proc: New()
|
||
// Parameters: None
|
||
// Description: Automatically assigns name according to ID tag.
|
||
/obj/machinery/power/sensor/New()
|
||
..()
|
||
auto_set_name()
|
||
|
||
// Proc: auto_set_name()
|
||
// Parameters: None
|
||
// Description: Sets name of this sensor according to the ID tag.
|
||
/obj/machinery/power/sensor/proc/auto_set_name()
|
||
name = "[name_tag] - Powernet Sensor"
|
||
|
||
// Proc: check_grid_warning()
|
||
// Parameters: None
|
||
// Description: Checks connected powernet for warnings. If warning is found returns 1
|
||
/obj/machinery/power/sensor/proc/check_grid_warning()
|
||
connect_to_network()
|
||
if(powernet)
|
||
if(powernet.problem)
|
||
return 1
|
||
return 0
|
||
|
||
// Proc: process()
|
||
// Parameters: None
|
||
// Description: This has to be here because we need sensors to remain in Machines list.
|
||
/obj/machinery/power/sensor/process()
|
||
return 1
|
||
|
||
// Proc: reading_to_text()
|
||
// Parameters: 1 (amount - Power in Watts to be converted to W, kW or MW)
|
||
// Description: Helper proc that converts reading in Watts to kW or MW (returns string version of amount parameter)
|
||
/obj/machinery/power/sensor/proc/reading_to_text(var/amount = 0)
|
||
var/units = ""
|
||
// 10kW and less - Watts
|
||
if(amount < 10000)
|
||
units = "W"
|
||
// 10MW and less - KiloWatts
|
||
else if(amount < 10000000)
|
||
units = "kW"
|
||
amount = (round(amount/100) / 10)
|
||
// More than 10MW - MegaWatts
|
||
else
|
||
units = "MW"
|
||
amount = (round(amount/10000) / 100)
|
||
if (units == "W")
|
||
return "[amount] W"
|
||
else
|
||
return "~[amount] [units]" //kW and MW are only approximate readings, therefore add "~"
|
||
|
||
// Proc: find_apcs()
|
||
// Parameters: None
|
||
// Description: Searches powernet for APCs and returns them in a list.
|
||
/obj/machinery/power/sensor/proc/find_apcs()
|
||
if(!powernet)
|
||
return
|
||
|
||
var/list/L = list()
|
||
for(var/obj/machinery/power/terminal/term in powernet.nodes)
|
||
if(istype(term.master, /obj/machinery/power/apc))
|
||
var/obj/machinery/power/apc/A = term.master
|
||
L += A
|
||
|
||
return L
|
||
|
||
|
||
// Proc: return_reading_text()
|
||
// Parameters: None
|
||
// Description: Generates string which contains HTML table with reading data.
|
||
/obj/machinery/power/sensor/proc/return_reading_text()
|
||
// No powernet. Try to connect to one first.
|
||
if(!powernet)
|
||
connect_to_network()
|
||
var/out = ""
|
||
if(!powernet) // No powernet.
|
||
out = "# SYSTEM ERROR - NO POWERNET #"
|
||
return out
|
||
|
||
|
||
var/list/L = find_apcs()
|
||
var/total_apc_load = 0
|
||
if(L.len <= 0) // No APCs found.
|
||
out = "<b>No APCs located in connected powernet!</b>"
|
||
else // APCs found. Create very ugly (but working!) HTML table.
|
||
|
||
out += "<table><tr><th>Name<th>EQUIP<th>LIGHT<th>ENVIRON<th>CELL<th>LOAD"
|
||
|
||
// These lists are used as replacement for number based APC settings
|
||
var/list/S = list("M-OFF","A-OFF","M-ON", "A-ON")
|
||
var/list/chg = list("N","C","F")
|
||
|
||
// Split to multiple lines to make it more readable
|
||
for(var/obj/machinery/power/apc/A in L)
|
||
out += "<tr><td>\The [A.area]" // Add area name
|
||
out += "<td>[S[A.equipment+1]]<td>[S[A.lighting+1]]<td>[S[A.environ+1]]" // Show status of channels
|
||
if(A.cell)
|
||
out += "<td>[round(A.cell.percent())]% - [chg[A.charging+1]]"
|
||
else
|
||
out += "<td>NO CELL"
|
||
var/load = A.lastused_total // Load.
|
||
total_apc_load += load
|
||
load = reading_to_text(load)
|
||
out += "<td>[load]"
|
||
|
||
out += "<br><b>TOTAL AVAILABLE: [reading_to_text(powernet.avail)]</b>"
|
||
out += "<br><b>APC LOAD: [reading_to_text(total_apc_load)]</b>"
|
||
out += "<br><b>OTHER LOAD: [reading_to_text(max(powernet.load - total_apc_load, 0))]</b>"
|
||
out += "<br><b>TOTAL GRID LOAD: [reading_to_text(powernet.viewload)] ([round((powernet.load / powernet.avail) * 100)]%)</b>"
|
||
|
||
if(powernet.problem)
|
||
out += "<br><b>WARNING: Abnormal grid activity detected!</b>"
|
||
return out
|
||
|
||
// Proc: return_reading_data()
|
||
// Parameters: None
|
||
// Description: Generates list containing all powernet data. Optimised for usage with NanoUI
|
||
/obj/machinery/power/sensor/proc/return_reading_data()
|
||
// No powernet. Try to connect to one first.
|
||
if(!powernet)
|
||
connect_to_network()
|
||
var/list/data = list()
|
||
data["name"] = name_tag
|
||
if(!powernet)
|
||
data["error"] = "# SYSTEM ERROR - NO POWERNET #"
|
||
data["alarm"] = 0 // Runtime Prevention
|
||
return data
|
||
|
||
var/list/L = find_apcs()
|
||
var/total_apc_load = 0
|
||
var/list/APC_data = list()
|
||
if(L.len > 0)
|
||
// These lists are used as replacement for number based APC settings
|
||
var/list/S = list("M-OFF","A-OFF","M-ON", "A-ON")
|
||
var/list/chg = list("N","C","F")
|
||
|
||
for(var/obj/machinery/power/apc/A in L)
|
||
var/list/APC_entry = list()
|
||
// Channel Statuses
|
||
APC_entry["s_equipment"] = S[A.equipment+1]
|
||
APC_entry["s_lighting"] = S[A.lighting+1]
|
||
APC_entry["s_environment"] = S[A.environ+1]
|
||
// Cell Status
|
||
APC_entry["cell_charge"] = A.cell ? round(A.cell.percent()) : "NO CELL"
|
||
APC_entry["cell_status"] = A.cell ? chg[A.charging+1] : "N"
|
||
// Other info
|
||
APC_entry["total_load"] = reading_to_text(A.lastused_total)
|
||
// Hopefully removes those goddamn \improper s which are screwing up the UI
|
||
var/N = A.area.name
|
||
if(findtext(N, "<22>"))
|
||
N = copytext(N, 3)
|
||
APC_entry["name"] = N
|
||
// Add data into main list of APC data.
|
||
APC_data += list(APC_entry)
|
||
// Add load of this APC to total APC load calculation
|
||
total_apc_load += A.lastused_total
|
||
data["apc_data"] = APC_data
|
||
data["total_avail"] = reading_to_text(max(powernet.avail, 0))
|
||
data["total_used_apc"] = reading_to_text(max(total_apc_load, 0))
|
||
data["total_used_other"] = reading_to_text(max(powernet.viewload - total_apc_load, 0))
|
||
data["total_used_all"] = reading_to_text(max(powernet.viewload, 0))
|
||
// Prevents runtimes when avail is 0 (division by zero)
|
||
if(powernet.avail)
|
||
data["load_percentage"] = round((powernet.viewload / powernet.avail) * 100)
|
||
else
|
||
data["load_percentage"] = 100
|
||
data["alarm"] = powernet.problem ? 1 : 0
|
||
return data
|
||
|
||
|
||
|
||
|
||
|