mwerezak bab998d011 Improves overshoot when filling air tanks.
Estimating the transfer amount assuming that the sink temperature remains unchanged, and then using that estimate to obtain an estimate for the final sink temperature. This is then used to obtain a final transfer amount in predictor-corrector fashion.