//base type for controllers of two-door systems
|
|
/obj/machinery/embedded_controller/radio/airlock
|
|
// Setup parameters only
|
|
radio_filter = RADIO_AIRLOCK
|
|
program = /datum/embedded_program/airlock
|
|
var/tag_exterior_door
|
|
var/tag_interior_door
|
|
var/tag_airpump
|
|
var/tag_chamber_sensor
|
|
var/tag_exterior_sensor
|
|
var/tag_interior_sensor
|
|
var/tag_airlock_mech_sensor
|
|
var/tag_shuttle_mech_sensor
|
|
var/tag_secure = 0
|
|
var/list/dummy_terminals = list()
|
|
var/cycle_to_external_air = 0
|
|
valid_actions = list("cycle_ext", "cycle_int", "force_ext", "force_int", "abort", "purge", "secure")
|
|
layer = ABOVE_WINDOW_LAYER
|
|
|
|
var/deconstructable = FALSE
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/Destroy()
|
|
// TODO - Leshana - Implement dummy terminals
|
|
//for(var/thing in dummy_terminals)
|
|
// var/obj/machinery/dummy_airlock_controller/dummy = thing
|
|
// dummy.master_controller = null
|
|
//dummy_terminals.Cut()
|
|
return ..()
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/tgui_status(mob/user, datum/tgui_state/state)
|
|
. = ..()
|
|
if(!allowed(user))
|
|
return min(STATUS_UPDATE, .)
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/attackby(obj/item/I, mob/user)
|
|
if(deconstructable)
|
|
if(default_deconstruction_screwdriver(user, I))
|
|
return
|
|
if(default_deconstruction_crowbar(user, I))
|
|
return
|
|
. = ..()
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/tgui_data(mob/user, datum/tgui/ui, datum/tgui_state/state)
|
|
var/list/data = ..()
|
|
|
|
data["panel_open"] = panel_open
|
|
data["tags"] = null
|
|
|
|
data["frequency"] = null
|
|
data["min_freq"] = null
|
|
data["max_freq"] = null
|
|
|
|
if(panel_open)
|
|
var/datum/embedded_program/airlock/airlock_program = program
|
|
data["tags"] = airlock_program.get_all_tags()
|
|
|
|
data["frequency"] = frequency
|
|
data["min_freq"] = RADIO_LOW_FREQ
|
|
data["max_freq"] = RADIO_HIGH_FREQ
|
|
|
|
return data
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/tgui_act(action, params)
|
|
. = ..()
|
|
if(.)
|
|
return
|
|
|
|
if(!panel_open)
|
|
return
|
|
|
|
switch(action)
|
|
if("edit_tag")
|
|
var/datum/embedded_program/airlock/airlock_program = program
|
|
|
|
var/tag = params["tag"]
|
|
var/current = airlock_program.get_tag(tag)
|
|
var/new_tag = tgui_input_text(usr, "What would you like to set [tag] to?", "New [tag]?", current, 30, FALSE, TRUE)
|
|
|
|
if(new_tag)
|
|
airlock_program.set_tag(tag, new_tag)
|
|
return TRUE
|
|
|
|
if("set_frequency")
|
|
set_frequency(sanitize_frequency(text2num(params["freq"]), RADIO_LOW_FREQ, RADIO_HIGH_FREQ))
|
|
return TRUE
|
|
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/update_icon()
|
|
cut_overlays()
|
|
if(panel_open)
|
|
add_overlay("airlock_control_open")
|
|
|
|
//Advanced airlock controller for when you want a more versatile airlock controller - useful for turning simple access control rooms into airlocks
|
|
/obj/machinery/embedded_controller/radio/airlock/advanced_airlock_controller
|
|
name = "Advanced Airlock Controller"
|
|
deconstructable = TRUE
|
|
circuit = /obj/item/circuitboard/airlock_cycling
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/advanced_airlock_controller/tgui_data(mob/user)
|
|
var/list/data = ..()
|
|
|
|
// Deliberately not using UNTYPED_LIST_ADD, we want this to be appended
|
|
data += list(
|
|
"chamber_pressure" = round(program.memory["chamber_sensor_pressure"]),
|
|
"external_pressure" = round(program.memory["external_sensor_pressure"]),
|
|
"internal_pressure" = round(program.memory["internal_sensor_pressure"]),
|
|
"processing" = program.memory["processing"],
|
|
"purge" = program.memory["purge"],
|
|
"secure" = program.memory["secure"],
|
|
"internalTemplateName" = "AirlockConsoleAdvanced",
|
|
)
|
|
|
|
return data
|
|
|
|
|
|
//Airlock controller for airlock control - most airlocks on the station use this
|
|
/obj/machinery/embedded_controller/radio/airlock/airlock_controller
|
|
name = "Airlock Controller"
|
|
tag_secure = 1
|
|
valid_actions = list("cycle_ext", "cycle_int", "force_ext", "force_int", "abort")
|
|
deconstructable = TRUE
|
|
circuit = /obj/item/circuitboard/airlock_cycling
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/airlock_controller/tgui_data(mob/user)
|
|
var/list/data = ..()
|
|
|
|
// Deliberately not using UNTYPED_LIST_ADD, we want this to be appended
|
|
data += list(
|
|
"chamber_pressure" = round(program.memory["chamber_sensor_pressure"]),
|
|
"exterior_status" = program.memory["exterior_status"],
|
|
"interior_status" = program.memory["interior_status"],
|
|
"processing" = program.memory["processing"],
|
|
"internalTemplateName" = "AirlockConsoleSimple",
|
|
)
|
|
|
|
return data
|
|
|
|
//Access controller for door control - used in virology and the like
|
|
/obj/machinery/embedded_controller/radio/airlock/access_controller
|
|
icon = 'icons/obj/airlock_machines.dmi'
|
|
icon_state = "access_control_standby"
|
|
|
|
name = "Access Controller"
|
|
tag_secure = 1
|
|
valid_actions = list("cycle_ext_door", "cycle_int_door", "force_ext", "force_int")
|
|
deconstructable = TRUE
|
|
circuit = /obj/item/circuitboard/airlock_cycling
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/access_controller/update_icon()
|
|
if(on && program)
|
|
if(program.memory["processing"])
|
|
icon_state = "access_control_process"
|
|
else
|
|
icon_state = "access_control_standby"
|
|
else
|
|
icon_state = "access_control_off"
|
|
|
|
/obj/machinery/embedded_controller/radio/airlock/access_controller/tgui_data(mob/user)
|
|
var/list/data = ..()
|
|
|
|
// Deliberately not using UNTYPED_LIST_ADD, we want this to be appended
|
|
data += list(
|
|
"exterior_status" = program.memory["exterior_status"],
|
|
"interior_status" = program.memory["interior_status"],
|
|
"processing" = program.memory["processing"],
|
|
"internalTemplateName" = "DoorAccessConsole",
|
|
)
|
|
|
|
return data
|