#define SSMACHINES_PIPENETS 1
#define SSMACHINES_MACHINERY 2
#define SSMACHINES_POWERNETS 3
#define SSMACHINES_POWER_OBJECTS 4
//
// SSmachines subsystem - Processing machines, pipenets, and powernets!
//
SUBSYSTEM_DEF(machines)
name = "Machines"
priority = FIRE_PRIORITY_MACHINES
init_order = INIT_ORDER_MACHINES
flags = SS_KEEP_TIMING
runlevels = RUNLEVEL_GAME|RUNLEVEL_POSTGAME
var/current_step = SSMACHINES_PIPENETS
var/cost_pipenets = 0
var/cost_machinery = 0
var/cost_powernets = 0
var/cost_power_objects = 0
var/list/current_run = list()
var/list/all_machines = list()
var/list/networks = list()
var/list/processing_machines = list()
var/list/powernets = list()
var/list/powerobjs = list()
/datum/controller/subsystem/machines/Initialize()
makepowernets()
admin_notice(span_danger("Initializing atmos machinery."), R_DEBUG)
setup_atmos_machinery(all_machines)
fire()
return SS_INIT_SUCCESS
/datum/controller/subsystem/machines/fire(resumed = 0)
var/timer = TICK_USAGE
INTERNAL_PROCESS_STEP(SSMACHINES_POWER_OBJECTS,FALSE,process_power_objects,cost_power_objects,SSMACHINES_PIPENETS) // Higher priority, damnit
INTERNAL_PROCESS_STEP(SSMACHINES_PIPENETS,TRUE,process_pipenets,cost_pipenets,SSMACHINES_MACHINERY)
INTERNAL_PROCESS_STEP(SSMACHINES_MACHINERY,FALSE,process_machinery,cost_machinery,SSMACHINES_POWERNETS)
INTERNAL_PROCESS_STEP(SSMACHINES_POWERNETS,FALSE,process_powernets,cost_powernets,SSMACHINES_POWER_OBJECTS)
// rebuild all power networks from scratch - only called at world creation or by the admin verb
// The above is a lie. Turbolifts also call this proc.
/datum/controller/subsystem/machines/proc/makepowernets()
// TODO - check to not run while in the middle of a tick!
for(var/datum/powernet/PN as anything in powernets)
qdel(PN)
powernets.Cut()
setup_powernets_for_cables(cable_list)
/datum/controller/subsystem/machines/proc/setup_powernets_for_cables(list/cables)
for(var/obj/structure/cable/PC as anything in cables)
if(!PC.powernet)
var/datum/powernet/NewPN = new()
NewPN.add_cable(PC)
propagate_network(PC,PC.powernet)
/datum/controller/subsystem/machines/proc/setup_atmos_machinery(list/atmos_machines)
var/list/actual_atmos_machines = list()
for(var/obj/machinery/atmospherics/machine in atmos_machines)
machine.atmos_init()
actual_atmos_machines += machine
CHECK_TICK
for(var/obj/machinery/atmospherics/machine as anything in actual_atmos_machines)
machine.build_network()
CHECK_TICK
for(var/obj/machinery/atmospherics/unary/U as anything in actual_atmos_machines)
if(istype(U, /obj/machinery/atmospherics/unary/vent_pump))
var/obj/machinery/atmospherics/unary/vent_pump/T = U
T.broadcast_status()
else if(istype(U, /obj/machinery/atmospherics/unary/vent_scrubber))
var/obj/machinery/atmospherics/unary/vent_scrubber/T = U
T.broadcast_status()
CHECK_TICK
/datum/controller/subsystem/machines/stat_entry(msg)
msg = "C:{"
msg += "PI:[round(cost_pipenets,1)]|"
msg += "MC:[round(cost_machinery,1)]|"
msg += "PN:[round(cost_powernets,1)]|"
msg += "PO:[round(cost_power_objects,1)]"
msg += "} "
msg += "PI:[SSmachines.networks.len]|"
msg += "MC:[SSmachines.processing_machines.len]|"
msg += "PN:[SSmachines.powernets.len]|"
msg += "PO:[SSmachines.powerobjs.len]|"
msg += "MC/MS:[round((cost ? SSmachines.processing_machines.len/cost_machinery : 0),0.1)]"
return ..()
/datum/controller/subsystem/machines/proc/process_pipenets(resumed = 0)
if (!resumed)
src.current_run = networks.Copy()
//cache for sanic speed (lists are references anyways)
var/wait = src.wait
var/list/current_run = src.current_run
while(current_run.len)
var/datum/pipe_network/PN = current_run[current_run.len]
current_run.len--
if(!PN || QDELETED(PN))
networks.Remove(PN)
DISABLE_BITFIELD(PN?.datum_flags, DF_ISPROCESSING)
else
PN.process(wait)
if(MC_TICK_CHECK)
return
/datum/controller/subsystem/machines/proc/process_machinery(resumed = 0)
if (!resumed)
src.current_run = processing_machines.Copy()
var/wait = src.wait
var/list/current_run = src.current_run
while(current_run.len)
var/obj/machinery/M = current_run[current_run.len]
current_run.len--
if(!istype(M) || QDELETED(M) || (M.process(wait) == PROCESS_KILL))
processing_machines.Remove(M)
DISABLE_BITFIELD(M?.datum_flags, DF_ISPROCESSING)
if(MC_TICK_CHECK)
return
/datum/controller/subsystem/machines/proc/process_powernets(resumed = 0)
if (!resumed)
src.current_run = powernets.Copy()
var/wait = src.wait
var/list/current_run = src.current_run
while(current_run.len)
var/datum/powernet/PN = current_run[current_run.len]
current_run.len--
if(!PN)
powernets.Remove(PN)
DISABLE_BITFIELD(PN?.datum_flags, DF_ISPROCESSING)
else
PN.reset(wait)
if(MC_TICK_CHECK)
return
// Actually only processes power DRAIN objects.
// Currently only used by powersinks. These items get priority processed before machinery
/datum/controller/subsystem/machines/proc/process_power_objects(resumed = 0)
if (!resumed)
src.current_run = powerobjs.Copy()
var/wait = src.wait
var/list/current_run = src.current_run
while(current_run.len)
var/obj/item/I = current_run[current_run.len]
current_run.len--
if(!I || (I.pwr_drain(wait) == PROCESS_KILL))
powerobjs.Remove(I)
DISABLE_BITFIELD(I?.datum_flags, DF_ISPROCESSING)
if(MC_TICK_CHECK)
return
/datum/controller/subsystem/machines/Recover()
for(var/datum/D as anything in SSmachines.networks)
if(!istype(D, /datum/pipe_network))
error("Found wrong type during SSmachinery recovery: list=SSmachines.networks, item=[D], type=[D?.type]")
SSmachines.networks -= D
for(var/datum/D as anything in SSmachines.processing_machines)
if(!istype(D, /obj/machinery))
error("Found wrong type during SSmachinery recovery: list=SSmachines.machines, item=[D], type=[D?.type]")
SSmachines.processing_machines -= D
for(var/datum/D as anything in SSmachines.powernets)
if(!istype(D, /datum/powernet))
error("Found wrong type during SSmachinery recovery: list=SSmachines.powernets, item=[D], type=[D?.type]")
SSmachines.powernets -= D
for(var/datum/D as anything in SSmachines.powerobjs)
if(!istype(D, /obj/item))
error("Found wrong type during SSmachinery recovery: list=SSmachines.powerobjs, item=[D], type=[D?.type]")
SSmachines.powerobjs -= D
all_machines = SSmachines.all_machines
networks = SSmachines.networks
processing_machines = SSmachines.processing_machines
powernets = SSmachines.powernets
powerobjs = SSmachines.powerobjs
#undef SSMACHINES_PIPENETS
#undef SSMACHINES_MACHINERY
#undef SSMACHINES_POWERNETS