#define DECLARE_TLV_VALUES var/red_min; var/yel_min; var/yel_max; var/red_max; var/tlv_comparitor;
|
|
#define LOAD_TLV_VALUES(x, y) red_min = x[1]; yel_min = x[2]; yel_max = x[3]; red_max = x[4]; tlv_comparitor = y;
|
|
#define TEST_TLV_VALUES (((tlv_comparitor > red_max && red_max > 0) || tlv_comparitor < red_min) ? 2 : ((tlv_comparitor > yel_max && yel_max > 0) || tlv_comparitor < yel_min) ? 1 : 0)
|
|
|
|
#define AALARM_MODE_SCRUBBING 1
|
|
#define AALARM_MODE_REPLACEMENT 2 //like scrubbing, but faster.
|
|
#define AALARM_MODE_PANIC 3 //constantly sucks all air
|
|
#define AALARM_MODE_CYCLE 4 //sucks off all air, then refill and switches to scrubbing
|
|
#define AALARM_MODE_FILL 5 //emergency fill
|
|
#define AALARM_MODE_OFF 6 //Shuts it all down.
|
|
|
|
#define AALARM_SCREEN_MAIN 1
|
|
#define AALARM_SCREEN_VENT 2
|
|
#define AALARM_SCREEN_SCRUB 3
|
|
#define AALARM_SCREEN_MODE 4
|
|
#define AALARM_SCREEN_SENSORS 5
|
|
|
|
#define AALARM_REPORT_TIMEOUT 100
|
|
|
|
#define MAX_TEMPERATURE 90
|
|
#define MIN_TEMPERATURE -40
|
|
|
|
//all air alarms in area are connected via freq 1439
|
|
/area
|
|
var/datum/weakref/main_air_alarm // The air alarm currently managing the others in the area, settings changes go to this one and propogate
|
|
var/list/air_vent_names = list()
|
|
var/list/air_scrub_names = list()
|
|
var/list/air_vent_info = list()
|
|
var/list/air_scrub_info = list()
|
|
var/list/air_alarms = list()
|
|
|
|
/area/proc/elect_main_air_alarm(var/exclude_self = FALSE)
|
|
// loop through all sensors to update the area's sensor list as well
|
|
main_air_alarm = null
|
|
var/list/checks = list()
|
|
for(var/obj/machinery/alarm/AA in air_alarms)
|
|
if(exclude_self && AA == src)
|
|
continue
|
|
if(!(AA.stat & (NOPOWER|BROKEN)))
|
|
checks += AA
|
|
if(!checks.len)
|
|
return
|
|
main_air_alarm = WEAKREF(pick(checks))
|
|
for(var/obj/machinery/alarm/AA in checks)
|
|
AA.update_icon()
|
|
|
|
/area/proc/main_air_alarm_is_operating()
|
|
var/obj/machinery/alarm/AM = main_air_alarm?.resolve()
|
|
return AM && !(AM.stat & (NOPOWER | BROKEN))
|
|
|
|
|
|
|
|
/obj/machinery/alarm
|
|
name = "alarm"
|
|
desc = "Used to control various station atmospheric systems. The light indicates the current air status of the area."
|
|
icon = 'icons/obj/monitors_vr.dmi'
|
|
icon_state = "alarm_0"
|
|
layer = ABOVE_WINDOW_LAYER
|
|
vis_flags = VIS_HIDE // They have an emissive that looks bad in openspace due to their wall-mounted nature
|
|
anchored = TRUE
|
|
unacidable = TRUE
|
|
use_power = USE_POWER_IDLE
|
|
idle_power_usage = 80
|
|
active_power_usage = 1000 //For heating/cooling rooms. 1000 joules equates to about 1 degree every 2 seconds for a single tile of air.
|
|
power_channel = ENVIRON
|
|
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_ENGINE_EQUIP)
|
|
clicksound = "button"
|
|
clickvol = 30
|
|
blocks_emissive = NONE
|
|
light_power = 0.25
|
|
var/alarm_id = null
|
|
var/breach_detection = 1 // Whether to use automatic breach detection or not
|
|
var/frequency = PUMPS_FREQ
|
|
//var/skipprocess = 0 //Experimenting
|
|
var/alarm_frequency = ALERT_FREQ
|
|
var/remote_control = 0
|
|
var/rcon_setting = 2
|
|
var/rcon_time = 0
|
|
var/locked = 1
|
|
panel_open = FALSE // If it's been screwdrivered open.
|
|
var/aidisabled = 0
|
|
var/shorted = 0
|
|
circuit = /obj/item/circuitboard/airalarm
|
|
|
|
var/datum/wires/alarm/wires
|
|
|
|
var/mode = AALARM_MODE_SCRUBBING
|
|
var/screen = AALARM_SCREEN_MAIN
|
|
var/area_uid
|
|
var/area/alarm_area
|
|
|
|
var/target_temperature = T0C+20
|
|
var/regulating_temperature = 0
|
|
|
|
var/datum/radio_frequency/radio_connection
|
|
|
|
/// Keys are things like temperature and certain gasses. Values are lists, which contain, in order:
|
|
/// red warning minimum value, yellow warning minimum value, yellow warning maximum value, red warning maximum value
|
|
/// Use code\defines\gases.dm as reference for id/name. Please keep it consistent
|
|
var/list/TLV = list()
|
|
var/list/trace_gas = list(GAS_N2O, GAS_VOLATILE_FUEL) //list of other gases that this air alarm is able to detect
|
|
|
|
var/danger_level = 0
|
|
var/pressure_dangerlevel = 0
|
|
|
|
var/report_danger_level = 1
|
|
|
|
var/alarms_hidden = FALSE //If the alarms from this machine are visible on consoles
|
|
|
|
var/datum/looping_sound/alarm/decompression_alarm/soundloop // CHOMPEdit: Looping Alarms
|
|
var/atmoswarn = FALSE // CHOMPEdit: Looping Alarms
|
|
|
|
/obj/machinery/alarm/nobreach
|
|
breach_detection = 0
|
|
|
|
/obj/machinery/alarm/monitor
|
|
report_danger_level = 0
|
|
breach_detection = 0
|
|
|
|
/obj/machinery/alarm/alarms_hidden
|
|
alarms_hidden = TRUE
|
|
|
|
/obj/machinery/alarm/angled
|
|
icon = 'icons/obj/wall_machines_angled.dmi'
|
|
|
|
/obj/machinery/alarm/angled/hidden
|
|
alarms_hidden = TRUE
|
|
|
|
/obj/machinery/alarm/angled/offset_airalarm()
|
|
pixel_x = (dir & 3) ? 0 : (dir == 4 ? -21 : 21)
|
|
pixel_y = (dir & 3) ? (dir == 1 ? -18 : 20) : 0
|
|
|
|
/obj/machinery/alarm/Initialize(mapload)
|
|
. = ..()
|
|
update_area()
|
|
set_frequency(frequency)
|
|
if(!pixel_x && !pixel_y)
|
|
offset_airalarm()
|
|
if(!wires)
|
|
wires = new(src)
|
|
alarm_area.air_alarms += src
|
|
if(!alarm_area.main_air_alarm_is_operating()) // select main alarm
|
|
alarm_area.elect_main_air_alarm()
|
|
set_initial_TLV()
|
|
|
|
/obj/machinery/alarm/Destroy()
|
|
unregister_radio(src, frequency)
|
|
qdel(wires)
|
|
wires = null
|
|
alarm_area.air_alarms -= src
|
|
if(alarm_area.main_air_alarm?.resolve() == src)
|
|
alarm_area.elect_main_air_alarm(TRUE)
|
|
alarm_area = null
|
|
QDEL_NULL(soundloop) // CHOMPEdit: Looping Alarms
|
|
. = ..()
|
|
|
|
/obj/machinery/alarm/proc/offset_airalarm()
|
|
pixel_x = (dir & 3) ? 0 : (dir == 4 ? -26 : 26)
|
|
pixel_y = (dir & 3) ? (dir == 1 ? -26 : 26) : 0
|
|
|
|
/obj/machinery/alarm/proc/set_initial_TLV()
|
|
// breathable air according to human/Life()
|
|
TLV[GAS_O2] = list(16, 19, 135, 140) // Partial pressure, kpa
|
|
TLV[GAS_N2] = list(0, 0, 135, 140) // Partial pressure, kpa
|
|
TLV[GAS_CO2] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa
|
|
TLV[GAS_PHORON] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa
|
|
TLV[GAS_CH4] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa
|
|
TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa
|
|
TLV["pressure"] = list(ONE_ATMOSPHERE * 0.80, ONE_ATMOSPHERE * 0.90, ONE_ATMOSPHERE * 1.10, ONE_ATMOSPHERE * 1.20) /* kpa */
|
|
TLV["temperature"] = list(T0C - 26, T0C, T0C + 40, T0C + 66) // K
|
|
|
|
update_icon()
|
|
|
|
/obj/machinery/alarm/proc/update_area()
|
|
alarm_area = get_area(src)
|
|
area_uid = "\ref[alarm_area]"
|
|
if(name == "alarm")
|
|
name = "[alarm_area.name] Air Alarm \[[rand(9999)]\]" // random number id to help with players locating alarms, cosmetic
|
|
|
|
// CHOMPAdd Start
|
|
/obj/machinery/alarm/Initialize(mapload)
|
|
. = ..()
|
|
soundloop = new(list(src), FALSE)
|
|
// CHOMPAdd ENd
|
|
|
|
/obj/machinery/alarm/proc/scan_atmo()
|
|
var/turf/simulated/location = src.loc
|
|
if(!istype(location)) return//returns if loc is not simulated
|
|
|
|
var/datum/gas_mixture/environment = location.return_air()
|
|
|
|
//Handle temperature adjustment here.
|
|
handle_heating_cooling(environment)
|
|
|
|
var/old_level = danger_level
|
|
var/old_pressurelevel = pressure_dangerlevel
|
|
danger_level = overall_danger_level(environment)
|
|
|
|
if(old_level != danger_level)
|
|
apply_danger_level(danger_level)
|
|
|
|
if(old_pressurelevel != pressure_dangerlevel)
|
|
if(breach_detected())
|
|
mode = AALARM_MODE_OFF
|
|
apply_mode()
|
|
|
|
if(mode == AALARM_MODE_CYCLE && environment.return_pressure() < ONE_ATMOSPHERE * 0.05)
|
|
mode = AALARM_MODE_FILL
|
|
apply_mode()
|
|
|
|
// CHOMPAdd Start
|
|
if(alarm_area?.atmosalm || danger_level > 0) // Looping Alarms (Trigger Decompression alarm here, on detection of any breach in the area)
|
|
soundloop.start()
|
|
atmoswarn = TRUE
|
|
else if(danger_level == 0 && alarm_area?.atmosalm == 0) // Looping Alarms (Cancel Decompression alarm here)
|
|
soundloop.stop()
|
|
atmoswarn = FALSE
|
|
// CHOMPAdd End
|
|
|
|
//atmos computer remote controll stuff
|
|
switch(rcon_setting)
|
|
if(RCON_NO)
|
|
remote_control = 0
|
|
if(RCON_AUTO)
|
|
if(danger_level == 2)
|
|
remote_control = 1
|
|
else
|
|
remote_control = 0
|
|
if(RCON_YES)
|
|
remote_control = 1
|
|
|
|
/obj/machinery/alarm/process()
|
|
if(!alarm_area)
|
|
return
|
|
var/obj/machinery/alarm/MA = alarm_area.main_air_alarm?.resolve()
|
|
if(!MA)
|
|
alarm_area.elect_main_air_alarm()
|
|
MA = alarm_area.main_air_alarm?.resolve() // try again
|
|
if(!MA || (stat & (NOPOWER|BROKEN)) || shorted || MA.shorted)
|
|
return
|
|
scan_atmo()
|
|
|
|
/obj/machinery/alarm/proc/handle_heating_cooling(var/datum/gas_mixture/environment)
|
|
DECLARE_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV["temperature"], target_temperature)
|
|
if(!regulating_temperature)
|
|
//check for when we should start adjusting temperature
|
|
if(!TEST_TLV_VALUES && abs(environment.temperature - target_temperature) > 2.0 && environment.return_pressure() >= 1)
|
|
update_use_power(USE_POWER_ACTIVE)
|
|
regulating_temperature = (environment.temperature > target_temperature ? 1 : 2)
|
|
audible_message("\The [src] clicks as it starts [regulating_temperature == 1 ? "cooling" : "heating"] the room.",\
|
|
"You hear a click and a faint electronic hum.", runemessage = "* click *")
|
|
playsound(src, 'sound/machines/click.ogg', 50, 1)
|
|
else
|
|
//check for when we should stop adjusting temperature
|
|
if(TEST_TLV_VALUES || abs(environment.temperature - target_temperature) <= 0.5 || environment.return_pressure() < 1)
|
|
update_use_power(USE_POWER_IDLE)
|
|
audible_message("\The [src] clicks quietly as it stops [regulating_temperature == 1 ? "cooling" : "heating"] the room.",\
|
|
"You hear a click as a faint electronic humming stops.", runemessage = "* click *")
|
|
regulating_temperature = 0
|
|
playsound(src, 'sound/machines/click.ogg', 50, 1)
|
|
|
|
if(regulating_temperature)
|
|
if(target_temperature > T0C + MAX_TEMPERATURE)
|
|
target_temperature = T0C + MAX_TEMPERATURE
|
|
|
|
if(target_temperature < T0C + MIN_TEMPERATURE)
|
|
target_temperature = T0C + MIN_TEMPERATURE
|
|
|
|
var/datum/gas_mixture/gas
|
|
gas = environment.remove(0.25 * environment.total_moles)
|
|
if(gas)
|
|
|
|
if(gas.temperature <= target_temperature) //gas heating
|
|
var/energy_used = min(gas.get_thermal_energy_change(target_temperature) , active_power_usage)
|
|
|
|
gas.add_thermal_energy(energy_used)
|
|
//use_power(energy_used, ENVIRON) //handle by update_use_power instead
|
|
else //gas cooling
|
|
var/heat_transfer = min(abs(gas.get_thermal_energy_change(target_temperature)), active_power_usage)
|
|
|
|
//Assume the heat is being pumped into the hull which is fixed at 20 C
|
|
//none of this is really proper thermodynamics but whatever
|
|
|
|
var/cop = gas.temperature / T20C //coefficient of performance -> power used = heat_transfer/cop
|
|
|
|
heat_transfer = min(heat_transfer, cop * active_power_usage) //this ensures that we don't use more than active_power_usage amount of power
|
|
|
|
heat_transfer = -gas.add_thermal_energy(-heat_transfer) //get the actual heat transfer
|
|
|
|
//use_power(heat_transfer / cop, ENVIRON) //handle by update_use_power instead
|
|
|
|
environment.merge(gas)
|
|
|
|
/obj/machinery/alarm/proc/overall_danger_level(var/datum/gas_mixture/environment)
|
|
var/partial_pressure = R_IDEAL_GAS_EQUATION * environment.temperature/environment.volume
|
|
var/environment_pressure = environment.return_pressure()
|
|
|
|
var/other_moles = 0
|
|
for(var/g in trace_gas)
|
|
other_moles += environment.gas[g] //this is only going to be used in a partial pressure calc, so we don't need to worry about group_multiplier here.
|
|
|
|
DECLARE_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV["pressure"], environment_pressure)
|
|
pressure_dangerlevel = TEST_TLV_VALUES // not local because it's used in process()
|
|
LOAD_TLV_VALUES(TLV[GAS_O2], environment.gas[GAS_O2]*partial_pressure)
|
|
var/oxygen_dangerlevel = TEST_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV[GAS_CO2], environment.gas[GAS_CO2]*partial_pressure)
|
|
var/co2_dangerlevel = TEST_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV[GAS_PHORON], environment.gas[GAS_PHORON]*partial_pressure)
|
|
var/phoron_dangerlevel = TEST_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV[GAS_CH4], environment.gas[GAS_CH4]*partial_pressure)
|
|
var/methane_dangerlevel = TEST_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV["temperature"], environment.temperature)
|
|
var/temperature_dangerlevel = TEST_TLV_VALUES
|
|
LOAD_TLV_VALUES(TLV["other"], other_moles*partial_pressure)
|
|
var/other_dangerlevel = TEST_TLV_VALUES
|
|
|
|
return max(
|
|
pressure_dangerlevel,
|
|
oxygen_dangerlevel,
|
|
co2_dangerlevel,
|
|
phoron_dangerlevel,
|
|
methane_dangerlevel,
|
|
other_dangerlevel,
|
|
temperature_dangerlevel
|
|
)
|
|
|
|
// Returns whether this air alarm thinks there is a breach, given the sensors that are available to it.
|
|
/obj/machinery/alarm/proc/breach_detected()
|
|
var/turf/simulated/location = src.loc
|
|
|
|
if(!istype(location))
|
|
return 0
|
|
|
|
if(breach_detection == 0)
|
|
return 0
|
|
|
|
var/datum/gas_mixture/environment = location.return_air()
|
|
var/environment_pressure = environment.return_pressure()
|
|
var/pressure_levels = TLV["pressure"]
|
|
|
|
if(environment_pressure <= pressure_levels[1]) //low pressures
|
|
if(!(mode == AALARM_MODE_PANIC || mode == AALARM_MODE_CYCLE))
|
|
return 1
|
|
|
|
return 0
|
|
|
|
/obj/machinery/alarm/update_icon()
|
|
// start actual update!
|
|
cut_overlays()
|
|
|
|
if(panel_open)
|
|
icon_state = "alarmx"
|
|
set_light(0)
|
|
set_light_on(FALSE)
|
|
return
|
|
if(!alarm_area || (stat & (NOPOWER|BROKEN)) || shorted)
|
|
icon_state = "alarmp"
|
|
set_light(0)
|
|
set_light_on(FALSE)
|
|
return
|
|
|
|
// sub light!
|
|
var/obj/machinery/alarm/MA = alarm_area.main_air_alarm?.resolve()
|
|
if(MA == src)
|
|
// I am the main alarm
|
|
add_overlay(mutable_appearance(icon, "alarm_Mmode"))
|
|
add_overlay(emissive_appearance(icon, "alarm_Mmode"))
|
|
if(!MA || MA.shorted)
|
|
// main alarm is out! don't show display!
|
|
icon_state = "alarmp"
|
|
add_overlay(mutable_appearance(icon, "alarm_Xmode"))
|
|
add_overlay(emissive_appearance(icon, "alarm_Xmode"))
|
|
set_light(0)
|
|
set_light_on(FALSE)
|
|
return
|
|
// passive light on
|
|
add_overlay(mutable_appearance(icon, "alarm_Pmode"))
|
|
add_overlay(emissive_appearance(icon, "alarm_Pmode"))
|
|
|
|
var/icon_level = danger_level
|
|
if(alarm_area.atmosalm)
|
|
icon_level = max(icon_level, 1) //if there's an atmos alarm but everything is okay locally, no need to go past yellow
|
|
|
|
var/new_color = null
|
|
switch(icon_level)
|
|
if(0)
|
|
icon_state = "alarm_0"
|
|
if(alarm_area.main_air_alarm?.resolve() == src)
|
|
// active controller
|
|
add_overlay(mutable_appearance(icon, "alarm_ov0"))
|
|
add_overlay(emissive_appearance(icon, "alarm_ov0"))
|
|
new_color = "#03A728"
|
|
else
|
|
// passive mode
|
|
add_overlay(mutable_appearance(icon, "alarm_ovP"))
|
|
add_overlay(emissive_appearance(icon, "alarm_ovP"))
|
|
new_color = "#0033FF"
|
|
if(1)
|
|
icon_state = "alarm_2" //yes, alarm2 is yellow alarm
|
|
add_overlay(mutable_appearance(icon, "alarm_ov2"))
|
|
add_overlay(emissive_appearance(icon, "alarm_ov2"))
|
|
new_color = "#EC8B2F"
|
|
if(2)
|
|
icon_state = "alarm_1"
|
|
add_overlay(mutable_appearance(icon, "alarm_ov1"))
|
|
add_overlay(emissive_appearance(icon, "alarm_ov1"))
|
|
new_color = "#DA0205"
|
|
|
|
set_light(l_range = 2, l_power = 0.25, l_color = new_color)
|
|
set_light_on(TRUE)
|
|
|
|
/obj/machinery/alarm/receive_signal(datum/signal/signal)
|
|
if(stat & (NOPOWER|BROKEN))
|
|
return
|
|
if(!signal || signal.encryption)
|
|
return
|
|
var/id_tag = signal.data["tag"]
|
|
if(!id_tag)
|
|
return
|
|
if(signal.data["area"] != area_uid)
|
|
return
|
|
if(signal.data["sigtype"] != "status")
|
|
return
|
|
|
|
var/dev_type = signal.data["device"]
|
|
if(!(id_tag in alarm_area.air_scrub_names) && !(id_tag in alarm_area.air_vent_names))
|
|
register_env_machine(id_tag, dev_type)
|
|
if(dev_type == "AScr")
|
|
alarm_area.air_scrub_info[id_tag] = signal.data
|
|
else if(dev_type == "AVP")
|
|
alarm_area.air_vent_info[id_tag] = signal.data
|
|
|
|
/obj/machinery/alarm/proc/register_env_machine(var/m_id, var/device_type)
|
|
var/new_name
|
|
if(device_type == "AVP")
|
|
new_name = "[alarm_area.name] Vent Pump #[alarm_area.air_vent_names.len+1]"
|
|
alarm_area.air_vent_names[m_id] = new_name
|
|
else if(device_type == "AScr")
|
|
new_name = "[alarm_area.name] Air Scrubber #[alarm_area.air_scrub_names.len+1]"
|
|
alarm_area.air_scrub_names[m_id] = new_name
|
|
else
|
|
return
|
|
addtimer(CALLBACK(src, PROC_REF(send_signal),m_id, list("init" = new_name)), 10, TIMER_DELETE_ME)
|
|
|
|
/obj/machinery/alarm/proc/refresh_all()
|
|
for(var/id_tag in alarm_area.air_vent_names)
|
|
var/list/I = alarm_area.air_vent_info[id_tag]
|
|
if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time)
|
|
continue
|
|
send_signal(id_tag, list("status"))
|
|
for(var/id_tag in alarm_area.air_scrub_names)
|
|
var/list/I = alarm_area.air_scrub_info[id_tag]
|
|
if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time)
|
|
continue
|
|
send_signal(id_tag, list("status"))
|
|
|
|
/obj/machinery/alarm/proc/set_frequency(new_frequency)
|
|
SSradio.remove_object(src, frequency)
|
|
frequency = new_frequency
|
|
radio_connection = SSradio.add_object(src, frequency, RADIO_TO_AIRALARM)
|
|
|
|
/obj/machinery/alarm/proc/send_signal(var/target, var/list/command)//sends signal 'command' to 'target'. Returns 0 if no radio connection, 1 otherwise
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = TRANSMISSION_RADIO //radio signal
|
|
signal.source = src
|
|
|
|
signal.data = command
|
|
signal.data["tag"] = target
|
|
signal.data["sigtype"] = "command"
|
|
|
|
radio_connection.post_signal(src, signal, RADIO_FROM_AIRALARM)
|
|
// to_world("Signal [command] Broadcasted to [target]")
|
|
|
|
return 1
|
|
|
|
/obj/machinery/alarm/proc/apply_mode()
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
AA.mode = mode //propagate mode to other air alarms in the area
|
|
|
|
switch(mode)
|
|
if(AALARM_MODE_SCRUBBING)
|
|
for(var/device_id in alarm_area.air_scrub_names)
|
|
send_signal(device_id, list("power"= 1, "co2_scrub"= 1, "scrubbing"= 1, "panic_siphon"= 0))
|
|
for(var/device_id in alarm_area.air_vent_names)
|
|
send_signal(device_id, list("power"= 1, "checks"= "default", "set_external_pressure"= "default"))
|
|
|
|
if(AALARM_MODE_PANIC, AALARM_MODE_CYCLE)
|
|
for(var/device_id in alarm_area.air_scrub_names)
|
|
send_signal(device_id, list("power"= 1, "panic_siphon"= 1))
|
|
for(var/device_id in alarm_area.air_vent_names)
|
|
send_signal(device_id, list("power"= 0))
|
|
|
|
if(AALARM_MODE_REPLACEMENT)
|
|
for(var/device_id in alarm_area.air_scrub_names)
|
|
send_signal(device_id, list("power"= 1, "panic_siphon"= 1))
|
|
for(var/device_id in alarm_area.air_vent_names)
|
|
send_signal(device_id, list("power"= 1, "checks"= "default", "set_external_pressure"= "default"))
|
|
|
|
if(AALARM_MODE_FILL)
|
|
for(var/device_id in alarm_area.air_scrub_names)
|
|
send_signal(device_id, list("power"= 0))
|
|
for(var/device_id in alarm_area.air_vent_names)
|
|
send_signal(device_id, list("power"= 1, "checks"= "default", "set_external_pressure"= "default"))
|
|
|
|
if(AALARM_MODE_OFF)
|
|
for(var/device_id in alarm_area.air_scrub_names)
|
|
send_signal(device_id, list("power"= 0))
|
|
for(var/device_id in alarm_area.air_vent_names)
|
|
send_signal(device_id, list("power"= 0))
|
|
|
|
/obj/machinery/alarm/proc/apply_danger_level(var/new_danger_level)
|
|
if(report_danger_level && alarm_area.atmosalert(new_danger_level, src))
|
|
post_alert(new_danger_level)
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
update_icon()
|
|
|
|
/obj/machinery/alarm/proc/post_alert(alert_level)
|
|
var/datum/radio_frequency/frequency = SSradio.return_frequency(alarm_frequency)
|
|
if(!frequency)
|
|
return
|
|
|
|
var/datum/signal/alert_signal = new
|
|
alert_signal.source = src
|
|
alert_signal.transmission_method = TRANSMISSION_RADIO
|
|
alert_signal.data["zone"] = alarm_area.name
|
|
alert_signal.data["type"] = "Atmospheric"
|
|
|
|
if(alert_level==2)
|
|
alert_signal.data["alert"] = "severe"
|
|
else if(alert_level==1)
|
|
alert_signal.data["alert"] = "minor"
|
|
else if(alert_level==0)
|
|
alert_signal.data["alert"] = "clear"
|
|
|
|
frequency.post_signal(src, alert_signal)
|
|
|
|
/obj/machinery/alarm/attack_ai(mob/user)
|
|
tgui_interact(user)
|
|
|
|
/obj/machinery/alarm/attack_hand(mob/user)
|
|
. = ..()
|
|
if(.)
|
|
return
|
|
return interact(user)
|
|
|
|
/obj/machinery/alarm/interact(mob/user)
|
|
tgui_interact(user)
|
|
wires.Interact(user)
|
|
|
|
/obj/machinery/alarm/tgui_status(mob/user)
|
|
if(isAI(user) && aidisabled)
|
|
to_chat(user, "AI control has been disabled.")
|
|
else if(!shorted)
|
|
return ..()
|
|
return STATUS_CLOSE
|
|
|
|
/obj/machinery/alarm/tgui_interact(mob/user, datum/tgui/ui, datum/tgui/parent_ui, datum/tgui_state/state)
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "AirAlarm", name, parent_ui)
|
|
if(state)
|
|
ui.set_state(state)
|
|
ui.open()
|
|
|
|
/obj/machinery/alarm/tgui_data(mob/user, datum/tgui/ui, datum/tgui_state/state)
|
|
var/list/data = list(
|
|
"locked" = locked,
|
|
"siliconUser" = siliconaccess(user) || (isobserver(user) && is_admin(user)),
|
|
"remoteUser" = !!ui.parent_ui,
|
|
"danger_level" = danger_level,
|
|
"target_temperature" = "[target_temperature - T0C]C",
|
|
"rcon" = rcon_setting,
|
|
)
|
|
|
|
var/area/A = get_area(src)
|
|
data["atmos_alarm"] = A?.atmosalm
|
|
data["fire_alarm"] = A?.fire
|
|
|
|
var/turf/T = get_turf(src)
|
|
var/datum/gas_mixture/environment = T.return_air()
|
|
|
|
var/list/list/environment_data = list()
|
|
data["environment_data"] = environment_data
|
|
|
|
DECLARE_TLV_VALUES
|
|
|
|
var/pressure = environment.return_pressure()
|
|
LOAD_TLV_VALUES(TLV["pressure"], pressure)
|
|
environment_data.Add(list(list(
|
|
"name" = "Pressure",
|
|
"value" = pressure,
|
|
"unit" = "kPa",
|
|
"danger_level" = TEST_TLV_VALUES
|
|
)))
|
|
|
|
var/temperature = environment.temperature
|
|
LOAD_TLV_VALUES(TLV["temperature"], temperature)
|
|
environment_data.Add(list(list(
|
|
"name" = "Temperature",
|
|
"value" = temperature,
|
|
"unit" = "K ([round(temperature - T0C, 0.1)]C)",
|
|
"danger_level" = TEST_TLV_VALUES
|
|
)))
|
|
|
|
var/total_moles = environment.total_moles
|
|
var/partial_pressure = R_IDEAL_GAS_EQUATION * environment.temperature / environment.volume
|
|
for(var/gas_id in environment.gas)
|
|
if(!(gas_id in TLV))
|
|
continue
|
|
LOAD_TLV_VALUES(TLV[gas_id], environment.gas[gas_id] * partial_pressure)
|
|
environment_data.Add(list(list(
|
|
"name" = gas_id,
|
|
"value" = environment.gas[gas_id] / total_moles * 100,
|
|
"unit" = "%",
|
|
"danger_level" = TEST_TLV_VALUES
|
|
)))
|
|
|
|
if(!locked || siliconaccess(user) || data["remoteUser"] || (isobserver(user) && is_admin(user)))
|
|
var/list/list/vents = list()
|
|
data["vents"] = vents
|
|
for(var/id_tag in A.air_vent_names)
|
|
var/long_name = A.air_vent_names[id_tag]
|
|
var/list/info = A.air_vent_info[id_tag]
|
|
if(!info)
|
|
continue
|
|
vents.Add(list(list(
|
|
"id_tag" = id_tag,
|
|
"long_name" = sanitize(long_name),
|
|
"power" = info["power"],
|
|
"checks" = info["checks"],
|
|
"excheck" = info["checks"]&1,
|
|
"incheck" = info["checks"]&2,
|
|
"direction" = info["direction"],
|
|
"external" = info["external"],
|
|
"internal" = info["internal"],
|
|
"extdefault"= (info["external"] == ONE_ATMOSPHERE),
|
|
"intdefault"= (info["internal"] == 0),
|
|
)))
|
|
|
|
|
|
var/list/list/scrubbers = list()
|
|
data["scrubbers"] = scrubbers
|
|
for(var/id_tag in alarm_area.air_scrub_names)
|
|
var/long_name = alarm_area.air_scrub_names[id_tag]
|
|
var/list/info = alarm_area.air_scrub_info[id_tag]
|
|
if(!info)
|
|
continue
|
|
scrubbers += list(list(
|
|
"id_tag" = id_tag,
|
|
"long_name" = sanitize(long_name),
|
|
"power" = info["power"],
|
|
"scrubbing" = info["scrubbing"],
|
|
"panic" = info["panic"],
|
|
"filters" = list(
|
|
list("name" = GASNAME_O2, "command" = "o2_scrub", "val" = info["filter_o2"]),
|
|
list("name" = GASNAME_N2, "command" = "n2_scrub", "val" = info["filter_n2"]),
|
|
list("name" = GASNAME_CO2, "command" = "co2_scrub", "val" = info["filter_co2"]),
|
|
list("name" = GASNAME_PHORON, "command" = "tox_scrub", "val" = info["filter_phoron"]),
|
|
list("name" = GASNAME_CH4, "command" = "ch4_scrub", "val" = info["filter_ch4"]),
|
|
list("name" = GASNAME_N2O, "command" = "n2o_scrub", "val" = info["filter_n2o"]),
|
|
list("name" = GASNAME_VOLATILE_FUEL,"command" = "fuel_scrub", "val" = info["filter_fuel"])
|
|
)
|
|
))
|
|
data["scrubbers"] = scrubbers
|
|
|
|
data["mode"] = mode
|
|
|
|
var/list/list/modes = list()
|
|
data["modes"] = modes
|
|
modes[++modes.len] = list("name" = "Filtering - Scrubs out contaminants", "mode" = AALARM_MODE_SCRUBBING, "selected" = mode == AALARM_MODE_SCRUBBING, "danger" = 0)
|
|
modes[++modes.len] = list("name" = "Replace Air - Siphons out air while replacing", "mode" = AALARM_MODE_REPLACEMENT, "selected" = mode == AALARM_MODE_REPLACEMENT, "danger" = 0)
|
|
modes[++modes.len] = list("name" = "Panic - Siphons air out of the room", "mode" = AALARM_MODE_PANIC, "selected" = mode == AALARM_MODE_PANIC, "danger" = 1)
|
|
modes[++modes.len] = list("name" = "Cycle - Siphons air before replacing", "mode" = AALARM_MODE_CYCLE, "selected" = mode == AALARM_MODE_CYCLE, "danger" = 1)
|
|
modes[++modes.len] = list("name" = "Fill - Shuts off scrubbers and opens vents", "mode" = AALARM_MODE_FILL, "selected" = mode == AALARM_MODE_FILL, "danger" = 0)
|
|
modes[++modes.len] = list("name" = "Off - Shuts off vents and scrubbers", "mode" = AALARM_MODE_OFF, "selected" = mode == AALARM_MODE_OFF, "danger" = 0)
|
|
|
|
var/list/selected
|
|
var/list/thresholds = list()
|
|
|
|
var/list/gas_names = list(GAS_O2, GAS_CO2, GAS_PHORON, GAS_CH4, "other") //Gas ids made to match code\defines\gases.dm
|
|
for(var/g in gas_names)
|
|
thresholds[++thresholds.len] = list("name" = g, "settings" = list())
|
|
selected = TLV[g]
|
|
for(var/i = 1, i <= 4, i++)
|
|
thresholds[thresholds.len]["settings"] += list(list("env" = g, "val" = i, "selected" = selected[i]))
|
|
|
|
selected = TLV["pressure"]
|
|
thresholds[++thresholds.len] = list("name" = "Pressure", "settings" = list())
|
|
for(var/i = 1, i <= 4, i++)
|
|
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = i, "selected" = selected[i]))
|
|
|
|
selected = TLV["temperature"]
|
|
thresholds[++thresholds.len] = list("name" = "Temperature", "settings" = list())
|
|
for(var/i = 1, i <= 4, i++)
|
|
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = i, "selected" = selected[i]))
|
|
|
|
data["thresholds"] = thresholds
|
|
return data
|
|
|
|
/obj/machinery/alarm/tgui_act(action, params, datum/tgui/ui, datum/tgui_state/state)
|
|
if(..())
|
|
return TRUE
|
|
|
|
if(action == "rcon")
|
|
var/attempted_rcon_setting = text2num(params["rcon"])
|
|
|
|
switch(attempted_rcon_setting)
|
|
if(RCON_NO)
|
|
rcon_setting = RCON_NO
|
|
if(RCON_AUTO)
|
|
rcon_setting = RCON_AUTO
|
|
if(RCON_YES)
|
|
rcon_setting = RCON_YES
|
|
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
AA.rcon_setting = rcon_setting
|
|
return TRUE
|
|
|
|
if(action == "temperature")
|
|
var/list/selected = TLV["temperature"]
|
|
var/max_temperature = min(selected[3] - T0C, MAX_TEMPERATURE)
|
|
var/min_temperature = max(selected[2] - T0C, MIN_TEMPERATURE)
|
|
var/input_temperature = tgui_input_number(ui.user, "What temperature would you like the system to mantain? (Capped between [min_temperature] and [max_temperature]C)", "Thermostat Controls", target_temperature - T0C, max_temperature, min_temperature, round_value = FALSE)
|
|
if(isnum(input_temperature))
|
|
if(input_temperature > max_temperature || input_temperature < min_temperature)
|
|
to_chat(ui.user, "Temperature must be between [min_temperature]C and [max_temperature]C")
|
|
else
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
AA.target_temperature = input_temperature + T0C
|
|
return TRUE
|
|
|
|
// Account for remote users here.
|
|
// Yes, this is kinda snowflaky; however, I would argue it would be far more snowflakey
|
|
// to include "custom hrefs" and all the other bullshit that nano states have just for the
|
|
// like, two UIs, that want remote access to other UIs.
|
|
if((locked && !(siliconaccess(ui.user) || (isobserver(ui.user) && is_admin(ui.user))) && !istype(state, /datum/tgui_state/air_alarm_remote)) || (issilicon(ui.user) && aidisabled))
|
|
return
|
|
|
|
var/device_id = params["id_tag"]
|
|
switch(action)
|
|
if("lock")
|
|
if((siliconaccess(ui.user) && !wires.is_cut(WIRE_IDSCAN)) || (isobserver(ui.user) && is_admin(ui.user)))
|
|
locked = !locked
|
|
. = TRUE
|
|
if( "power",
|
|
"o2_scrub",
|
|
"n2_scrub",
|
|
"co2_scrub",
|
|
"tox_scrub",
|
|
"n2o_scrub",
|
|
"fuel_scrub",
|
|
"ch4_scrub",
|
|
"panic_siphon",
|
|
"scrubbing",
|
|
"direction")
|
|
send_signal(device_id, list("[action]" = text2num(params["val"])), ui.user)
|
|
. = TRUE
|
|
if("excheck")
|
|
send_signal(device_id, list("checks" = text2num(params["val"])^1), ui.user)
|
|
. = TRUE
|
|
if("incheck")
|
|
send_signal(device_id, list("checks" = text2num(params["val"])^2), ui.user)
|
|
. = TRUE
|
|
if("set_external_pressure", "set_internal_pressure")
|
|
var/target = params["value"]
|
|
if(!isnull(target))
|
|
send_signal(device_id, list("[action]" = target), ui.user)
|
|
. = TRUE
|
|
if("reset_external_pressure")
|
|
send_signal(device_id, list("reset_external_pressure"), ui.user)
|
|
. = TRUE
|
|
if("reset_internal_pressure")
|
|
send_signal(device_id, list("reset_internal_pressure"), ui.user)
|
|
. = TRUE
|
|
if("threshold")
|
|
var/env = params["env"]
|
|
|
|
var/name = params["var"]
|
|
var/value = tgui_input_number(ui.user, "New [name] for [env]:", name, TLV[env][name], min_value=-1, round_value = FALSE)
|
|
if(!isnull(value) && !..())
|
|
if(value < 0)
|
|
TLV[env][name] = -1
|
|
else
|
|
TLV[env][name] = round(value, 0.01)
|
|
clamp_tlv_values(env, name)
|
|
// investigate_log(" treshold value for [env]:[name] was set to [value] by [key_name(ui.user)]",INVESTIGATE_ATMOS)
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
AA.TLV[env][name] = TLV[env][name]
|
|
. = TRUE
|
|
if("mode")
|
|
mode = text2num(params["mode"])
|
|
// investigate_log("was turned to [get_mode_name(mode)] mode by [key_name(ui.user)]",INVESTIGATE_ATMOS)
|
|
apply_mode(ui.user)
|
|
. = TRUE
|
|
if("alarm")
|
|
if(alarm_area.atmosalert(2, src))
|
|
apply_danger_level(2)
|
|
. = TRUE
|
|
if("reset")
|
|
atmos_reset()
|
|
. = TRUE
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
update_icon()
|
|
|
|
// This big ol' mess just ensures that TLV always makes sense. If you set the max value below the min value,
|
|
// it'll automatically update all the other values to keep it sane.
|
|
/obj/machinery/alarm/proc/clamp_tlv_values(env, changed_threshold)
|
|
var/list/selected = TLV[env]
|
|
switch(changed_threshold)
|
|
if(1)
|
|
if(selected[1] > selected[2])
|
|
selected[2] = selected[1]
|
|
if(selected[1] > selected[3])
|
|
selected[3] = selected[1]
|
|
if(selected[1] > selected[4])
|
|
selected[4] = selected[1]
|
|
if(2)
|
|
if(selected[1] > selected[2])
|
|
selected[1] = selected[2]
|
|
if(selected[2] > selected[3])
|
|
selected[3] = selected[2]
|
|
if(selected[2] > selected[4])
|
|
selected[4] = selected[2]
|
|
if(3)
|
|
if(selected[1] > selected[3])
|
|
selected[1] = selected[3]
|
|
if(selected[2] > selected[3])
|
|
selected[2] = selected[3]
|
|
if(selected[3] > selected[4])
|
|
selected[4] = selected[3]
|
|
if(4)
|
|
if(selected[1] > selected[4])
|
|
selected[1] = selected[4]
|
|
if(selected[2] > selected[4])
|
|
selected[2] = selected[4]
|
|
if(selected[3] > selected[4])
|
|
selected[3] = selected[4]
|
|
|
|
|
|
|
|
|
|
/obj/machinery/alarm/proc/atmos_reset()
|
|
if(alarm_area.atmosalert(0, src))
|
|
apply_danger_level(0)
|
|
for(var/obj/machinery/alarm/AA in alarm_area.air_alarms)
|
|
update_icon()
|
|
|
|
/obj/machinery/alarm/attackby(obj/item/W as obj, mob/user)
|
|
add_fingerprint(user)
|
|
if(alarm_deconstruction_screwdriver(user, W))
|
|
return
|
|
if(alarm_deconstruction_wirecutters(user, W))
|
|
return
|
|
|
|
if(istype(W, /obj/item/card/id) || istype(W, /obj/item/pda))// trying to unlock the interface with an ID card
|
|
togglelock(user)
|
|
return ..()
|
|
|
|
/obj/machinery/alarm/proc/togglelock(mob/user)
|
|
if(stat & (NOPOWER|BROKEN))
|
|
to_chat(user, "It does nothing.")
|
|
return
|
|
else
|
|
if(allowed(user) && !wires.is_cut(WIRE_IDSCAN))
|
|
locked = !locked
|
|
to_chat(user, span_notice("You [locked ? "lock" : "unlock"] the Air Alarm interface."))
|
|
else
|
|
to_chat(user, span_warning("Access denied."))
|
|
return
|
|
|
|
/obj/machinery/alarm/AltClick(mob/user)
|
|
..()
|
|
togglelock(user)
|
|
|
|
/obj/machinery/alarm/power_change()
|
|
..()
|
|
var/delay_time = rand(0,15)
|
|
if(delay_time)
|
|
addtimer(CALLBACK(src, PROC_REF(process_power_change)), delay_time, TIMER_DELETE_ME) // CHOMPEdit
|
|
return
|
|
process_power_change()
|
|
|
|
// CHOMPAdd Start
|
|
/obj/machinery/alarm/proc/process_power_change()
|
|
update_icon()
|
|
if(!soundloop)
|
|
return
|
|
if(stat & (NOPOWER | BROKEN))
|
|
soundloop.stop()
|
|
else if(atmoswarn)
|
|
soundloop.start()
|
|
// CHOMPAdd End
|
|
|
|
/obj/machinery/alarm/server/Initialize(mapload)
|
|
. = ..()
|
|
req_access = list(ACCESS_RD, ACCESS_ATMOSPHERICS, ACCESS_ENGINE_EQUIP)
|
|
TLV[GAS_O2] = list(-1.0, -1.0,-1.0,-1.0) // Partial pressure, kpa
|
|
TLV[GAS_CO2] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa
|
|
TLV[GAS_PHORON] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa
|
|
TLV[GAS_CH4] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa
|
|
TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa
|
|
TLV["pressure"] = list(0,ONE_ATMOSPHERE*0.10,ONE_ATMOSPHERE*1.40,ONE_ATMOSPHERE*1.60) /* kpa */
|
|
TLV["temperature"] = list(20, 40, 140, 160) // K
|
|
target_temperature = 90
|
|
|
|
/obj/machinery/alarm/freezer
|
|
target_temperature = T0C - 13.15 // Chilly freezer room
|
|
|
|
/obj/machinery/alarm/freezer/set_initial_TLV()
|
|
. = ..()
|
|
|
|
TLV["temperature"] = list(T0C - 40, T0C - 20, T0C + 40, T0C + 66) // K, Lower Temperature for Freezer Air Alarms (This is because TLV is hardcoded to be generated on first_run, and therefore the only way to modify this without changing TLV generation)
|
|
|
|
// CHOMPEdit START
|
|
/obj/machinery/alarm/sifwilderness
|
|
breach_detection = 0
|
|
report_danger_level = 0
|
|
|
|
/obj/machinery/alarm/sifwilderness/set_initial_TLV()
|
|
. = ..()
|
|
|
|
TLV["oxygen"] = list(16, 17, 135, 140)
|
|
TLV["pressure"] = list(0,ONE_ATMOSPHERE*0.10,ONE_ATMOSPHERE*1.50,ONE_ATMOSPHERE*1.60)
|
|
TLV["temperature"] = list(T0C - 40, T0C - 31, T0C + 40, T0C + 120)
|
|
// CHOMPEdit END
|
|
|
|
#undef LOAD_TLV_VALUES
|
|
#undef TEST_TLV_VALUES
|
|
#undef DECLARE_TLV_VALUES
|
|
|
|
#undef AALARM_MODE_SCRUBBING
|
|
#undef AALARM_MODE_REPLACEMENT
|
|
#undef AALARM_MODE_PANIC
|
|
#undef AALARM_MODE_CYCLE
|
|
#undef AALARM_MODE_FILL
|
|
#undef AALARM_MODE_OFF
|
|
|
|
#undef AALARM_SCREEN_MAIN
|
|
#undef AALARM_SCREEN_VENT
|
|
#undef AALARM_SCREEN_SCRUB
|
|
#undef AALARM_SCREEN_MODE
|
|
#undef AALARM_SCREEN_SENSORS
|
|
|
|
#undef AALARM_REPORT_TIMEOUT
|
|
|
|
#undef MAX_TEMPERATURE
|
|
#undef MIN_TEMPERATURE
|