Files
CHOMPStation2/code/modules/power/sensors/powernet_sensor.dm

89 lines
3.0 KiB
Plaintext

/*
********** POWERNET SENSOR **********
- Simple machine which detects power levels in cables under it.
- Used with power_monitor.dm to measure power levels around station.
- Can have ID tag for organisation purposes.
*/
/obj/machinery/power/sensor
name = "Powernet Sensor"
desc = "Small machine which transmits data about specific powernet"
anchored = 1
density = 0
layer = 2.46 // Above cables, but should be below floors.
icon = 'icons/obj/objects.dmi'
icon_state = "floor_beacon" // If anyone wants to make better sprite, feel free to do so without asking me.
var/name_tag = "#UNKN#" // ID tag displayed in list of powernet sensors. Each sensor should have it's own tag!
var/long_range = 0 // If 1, sensor reading will show on all computers, regardless of Zlevel
/obj/machinery/power/sensor/New()
..()
name = "[name_tag] - Powernet Sensor" // Auto-name according to name_tag
/obj/machinery/power/sensor/proc/RefreshGrid()
connect_to_network()
/obj/machinery/power/sensor/proc/ReturnReading()
var/out = ""
RefreshGrid() // First try to refresh the grid.
if(!powernet) // No powernet.
out = "# SYSTEM ERROR - NO POWERNET #"
return out
// Attempt to locate APCs in powernet
var/list/L = list()
for(var/obj/machinery/power/terminal/term in powernet.nodes)
if(istype(term.master, /obj/machinery/power/apc))
var/obj/machinery/power/apc/A = term.master
L += A
if(L.len <= 0) // No APCs found.
out = "<b>No APCs located in connected powernet!</b>"
else // APCs found. Create very ugly (but working!) HTML table.
var/total_load = 0
out += "<table><tr><th>Name<th>EQUIP<th>LIGHT<th>ENVIRON<th>CELL<th>LOAD"
// These lists are used as replacement for number based APC settings
var/list/S = list("M-OFF","A-OFF","M-ON", "A-ON")
var/list/chg = list("N","C","F")
// Split to multiple lines to make it more readable
for(var/obj/machinery/power/apc/A in L)
out += "<tr><td>\The [A.area]" // Add area name
out += "<td>[S[A.equipment+1]]<td>[S[A.lighting+1]]<td>[S[A.environ+1]]" // Show status of channels
if(A.cell)
out += "<td>[round(A.cell.percent())]% - [chg[A.charging+1]]"
else
out += "<td>NO CELL"
var/load = A.lastused_total // Load.
total_load += load
if(load > 1000)
load = "~[round(load/1000)]kW" // If above 1000W convert to Kilowatts.
else
load = "[round(load)]W" // Below 1000W, leave it in Watts
out += "<td>[load]" // Add load info
if (total_load > 1000)
total_load = "~[round(total_load/1000)] kW"
else
total_load = "[round(total_load)] W"
out += "</table>"
var/textavail = powernet.avail
if(textavail > 1000)
textavail = "[textavail / 1000]"
textavail += " kW"
else
textavail += " W"
if(powernet.problem)
out += "<br><b>WARNING: Abnormal grid activity detected!</b>"
out += "<br><b>TOTAL GRID LOAD: [total_load]</b>"
out += "<br><b>TOTAL AVAILABLE: [textavail]</b>"
return out
// Has to be here as we need it to be in Machines list.
/obj/machinery/power/sensor/process()
return 1