mirror of
https://github.com/CHOMPstation/CHOMPstation.git
synced 2026-07-21 20:12:31 +01:00
Adds mwerezak's suggestions
- Power monitor is now /computer/ subtype - Different rounding of values in power monitor display - Unfortunately, PDA power monitoring for engineers is broken and probably won't be fixed as it relies on old powernet monitoring computers. Laptops work OK
This commit is contained in:
@@ -59,13 +59,13 @@
|
||||
var/load = A.lastused_total // Load.
|
||||
total_load += load
|
||||
if(load > 1000)
|
||||
load = "~[round(load/1000)]kW" // If above 1000W convert to Kilowatts.
|
||||
load = "~[round(load/100)/10]kW" // If above 1000W convert to Kilowatts.
|
||||
else
|
||||
load = "[round(load)]W" // Below 1000W, leave it in Watts
|
||||
out += "<td>[load]" // Add load info
|
||||
|
||||
if (total_load > 1000)
|
||||
total_load = "~[round(total_load/1000)] kW"
|
||||
total_load = "~[round(total_load/100)/10] kW"
|
||||
else
|
||||
total_load = "[round(total_load)] W"
|
||||
|
||||
@@ -73,7 +73,7 @@
|
||||
|
||||
var/textavail = powernet.avail
|
||||
if(textavail > 1000)
|
||||
textavail = "[textavail / 1000] kW"
|
||||
textavail = "[round(textavail/100)/10] kW"
|
||||
else
|
||||
textavail = "[textavail] W"
|
||||
out += "<br><b>TOTAL AVAILABLE: [textavail]</b>"
|
||||
|
||||
@@ -4,7 +4,7 @@
|
||||
- Should filter out most duplicities.
|
||||
*/
|
||||
|
||||
/obj/machinery/power/monitor
|
||||
/obj/machinery/computer/power_monitor
|
||||
name = "Power Monitor"
|
||||
desc = "Computer designed to remotely monitor power levels around the station"
|
||||
icon = 'icons/obj/computer.dmi'
|
||||
@@ -13,7 +13,7 @@
|
||||
//computer stuff
|
||||
density = 1
|
||||
anchored = 1.0
|
||||
var/circuit = /obj/item/weapon/circuitboard/powermonitor
|
||||
circuit = /obj/item/weapon/circuitboard/powermonitor
|
||||
var/list/grid_sensors = null
|
||||
var/update_counter = 0 // Next icon update when this reaches 5 (ie every 5 ticks)
|
||||
var/active_sensor = null
|
||||
@@ -22,17 +22,17 @@
|
||||
active_power_usage = 300
|
||||
|
||||
// Update icon every 5 ticks.
|
||||
/obj/machinery/power/monitor/process()
|
||||
/obj/machinery/computer/power_monitor/process()
|
||||
update_counter++
|
||||
if(update_counter > 4)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/power/monitor/New()
|
||||
/obj/machinery/computer/power_monitor/New()
|
||||
..()
|
||||
refresh_sensors()
|
||||
|
||||
|
||||
/obj/machinery/power/monitor/proc/refresh_sensors()
|
||||
/obj/machinery/computer/power_monitor/proc/refresh_sensors()
|
||||
grid_sensors = list()
|
||||
for(var/obj/machinery/power/sensor/S in machines)
|
||||
if((S.loc.z == src.loc.z) || (S.long_range)) // Consoles have range on their Z-Level. Sensors with long_range var will work between Z levels.
|
||||
@@ -42,21 +42,21 @@
|
||||
grid_sensors += S
|
||||
|
||||
|
||||
/obj/machinery/power/monitor/attack_ai(mob/user)
|
||||
/obj/machinery/computer/power_monitor/attack_ai(mob/user)
|
||||
add_fingerprint(user)
|
||||
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
interact(user)
|
||||
|
||||
/obj/machinery/power/monitor/attack_hand(mob/user)
|
||||
/obj/machinery/computer/power_monitor/attack_hand(mob/user)
|
||||
add_fingerprint(user)
|
||||
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
interact(user)
|
||||
|
||||
/obj/machinery/power/monitor/interact(mob/user)
|
||||
/obj/machinery/computer/power_monitor/interact(mob/user)
|
||||
|
||||
if ( (get_dist(src, user) > 1 ) || (stat & (BROKEN|NOPOWER)) )
|
||||
if (!istype(user, /mob/living/silicon))
|
||||
@@ -95,7 +95,10 @@
|
||||
t += "<B>ERROR - No Active Sensors Detected!</B>"
|
||||
else
|
||||
for(var/obj/machinery/power/sensor/S in grid_sensors) // Show all data from current Z level.
|
||||
t += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
|
||||
if(S.check_grid_warning()) // Display grids with active alarms in bold text
|
||||
t += "<B><A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A></B><BR>"
|
||||
else
|
||||
t += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
|
||||
|
||||
|
||||
|
||||
@@ -103,7 +106,7 @@
|
||||
onclose(user, "powcomp")
|
||||
|
||||
|
||||
/obj/machinery/power/monitor/Topic(href, href_list)
|
||||
/obj/machinery/computer/power_monitor/Topic(href, href_list)
|
||||
..()
|
||||
if( href_list["close"] )
|
||||
usr << browse(null, "window=powcomp")
|
||||
@@ -120,7 +123,7 @@
|
||||
active_sensor = href_list["setsensor"]
|
||||
src.updateDialog()
|
||||
|
||||
/obj/machinery/power/monitor/update_icon()
|
||||
/obj/machinery/computer/power_monitor/update_icon()
|
||||
update_counter = 0 // Reset the icon update counter.
|
||||
if(stat & BROKEN)
|
||||
icon_state = "powerb"
|
||||
@@ -134,7 +137,7 @@
|
||||
|
||||
icon_state = "power"
|
||||
|
||||
/obj/machinery/power/monitor/proc/check_warnings()
|
||||
/obj/machinery/computer/power_monitor/proc/check_warnings()
|
||||
var/warn = 0
|
||||
if(grid_sensors)
|
||||
for(var/obj/machinery/power/sensor/S in grid_sensors)
|
||||
@@ -143,7 +146,7 @@
|
||||
return warn
|
||||
|
||||
|
||||
/obj/machinery/power/monitor/power_change()
|
||||
/obj/machinery/computer/power_monitor/power_change()
|
||||
..()
|
||||
|
||||
// Leaving this here to preserve that delayed shutdown effect when power goes out.
|
||||
@@ -153,7 +156,7 @@
|
||||
else
|
||||
update_icon()
|
||||
|
||||
|
||||
/*
|
||||
//copied from computer.dm
|
||||
/obj/machinery/power/monitor/attackby(I as obj, user as mob)
|
||||
if(istype(I, /obj/item/weapon/screwdriver) && circuit)
|
||||
@@ -178,4 +181,5 @@
|
||||
del(src)
|
||||
else
|
||||
src.attack_hand(user)
|
||||
return
|
||||
return
|
||||
*/
|
||||
Reference in New Issue