Merge branch 'dev-freeze' of https://github.com/Baystation12/Baystation12 into essEssDee

This commit is contained in:
Ravensdale
2014-12-27 10:26:24 -08:00
3 changed files with 52 additions and 23 deletions
@@ -55,4 +55,7 @@
canmove = 1
use_me = 1 //If it can move, let it emote
else canmove = 0
return canmove
return canmove
/mob/living/carbon/brain/binarycheck()
return istype(loc, /obj/item/device/mmi/digital)
+8 -3
View File
@@ -2,8 +2,8 @@
/mob/living/carbon/brain/say(var/message)
if (silent)
return
if(!(container && istype(container, /obj/item/device/mmi)))
if(!(container && istype(container, /obj/item/device/mmi)))
return //No MMI, can't speak, bucko./N
else
var/datum/language/speaking = parse_language(message)
@@ -24,8 +24,13 @@
return
else
message = Gibberish(message, (emp_damage*6))//scrambles the message, gets worse when emp_damage is higher
if(speaking && speaking.flags & HIVEMIND)
speaking.broadcast(src,trim(message))
return
if(istype(container, /obj/item/device/mmi/radio_enabled))
var/obj/item/device/mmi/radio_enabled/R = container
if(R.radio)
spawn(0) R.radio.hear_talk(src, trim(sanitize(message)), verb, speaking)
..()
..(trim(message), speaking, verb)
+40 -19
View File
@@ -15,8 +15,9 @@
anchored = 1.0
circuit = /obj/item/weapon/circuitboard/powermonitor
var/list/grid_sensors = null
var/update_counter = 0 // Next icon update when this reaches 5 (ie every 5 ticks)
var/active_sensor = null
var/list/sensors_by_powernet = null
var/update_counter = 0 // Next icon update when this reaches 5 (ie every 5 ticks)
var/active_sensor = null //name_tag of the currently selected sensor
use_power = 1
idle_power_usage = 300
active_power_usage = 300
@@ -34,12 +35,19 @@
/obj/machinery/computer/power_monitor/proc/refresh_sensors()
grid_sensors = list()
sensors_by_powernet = list()
for(var/obj/machinery/power/sensor/S in machines)
if((S.loc.z == src.loc.z) || (S.long_range)) // Consoles have range on their Z-Level. Sensors with long_range var will work between Z levels.
if(S.name_tag == "#UNKN#") // Default name. Shouldn't happen!
error("Powernet sensor with unset ID Tag! [S.x]X [S.y]Y [S.z]Z")
else
grid_sensors += S
grid_sensors[S.name_tag] = S
var/pnet = (S.powernet)? S.powernet : "none"
if (pnet in sensors_by_powernet)
sensors_by_powernet[pnet] += S
else
sensors_by_powernet[pnet] = list(S)
/obj/machinery/computer/power_monitor/attack_ai(mob/user)
@@ -75,13 +83,10 @@
t += "<BR><A href='?src=\ref[src];close=1'>Close</A><BR><HR>"
if(!grid_sensors)
t += "Unable to connect to sensor!"
t += "No sensors available."
else
var/obj/machinery/power/sensor/OKS = null
for(var/obj/machinery/power/sensor/S in grid_sensors)
if(S.name_tag == active_sensor)
OKS = S
if(OKS)
if (active_sensor in grid_sensors)
var/obj/machinery/power/sensor/OKS = grid_sensors[active_sensor]
t += "<B>[OKS.name_tag] - Sensor Reading</B><BR>"
t += OKS.ReturnReading()
else
@@ -91,20 +96,36 @@
else
t += "<BR><A href='?src=\ref[src];update=1'>Refresh</A>"
t += "<BR><A href='?src=\ref[src];close=1'>Close</A><BR><HR>"
if((!grid_sensors) || (!grid_sensors.len))
t += "<B>ERROR - No Active Sensors Detected!</B>"
else
for(var/obj/machinery/power/sensor/S in grid_sensors) // Show all data from current Z level.
if(S.check_grid_warning()) // Display grids with active alarms in bold text
t += "<B><A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A></B><BR>"
else
t += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
t += render_sensor_list()
user << browse(t, "window=powcomp;size=600x900")
onclose(user, "powcomp")
/obj/machinery/computer/power_monitor/proc/render_sensor_list()
if((!grid_sensors) || (!grid_sensors.len))
return "<B>ERROR - No Active Sensors Detected!</B>"
var/html = "<table border='0'><tr><th>Power Network</th><th>Sensors</th></tr>"
for (var/pnet in sensors_by_powernet)
if (pnet && pnet != "none")
html += "<tr><td valign='top'>[uppertext("\ref[pnet]")]</td><td>"
for(var/obj/machinery/power/sensor/S in sensors_by_powernet[pnet])
//really, if one of them has a warning, they all should - but the interface doesn't guarantee that so whatever
if(S.check_grid_warning()) // Display grids with active alarms in bold text
html += "<B><A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A></B><BR>"
else
html += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
html += "</td></tr>"
if ("none" in sensors_by_powernet)
html += "<tr><td>\[N/A\]</td><td>"
for(var/obj/machinery/power/sensor/S in sensors_by_powernet["none"])
html += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
html += "</td></tr>"
html += "</table>"
return html
/obj/machinery/computer/power_monitor/Topic(href, href_list)
..()