* Alarm -- Provides a visual indication when air quality is unbreathable (toxins, low pressure, etc.)
*
*/
obj/machinery/alarm
name = "alarm"
icon = 'stationobjs.dmi'
icon_state = "alarm:0"
anchored = 1.0
layer = 3.1
// Monitors location air quality and changes icon_state to reflect it
process()
if(stat & NOPOWER)
icon_state = "alarm-p"
return
use_power(5, ENVIRON)
var/safe = 1
var/turf/T = src.loc
if (!( istype(T, /turf) ))
return
if (locate(/obj/move, T))
T = locate(/obj/move, T)
var/turf_total = T.co2 + T.oxygen + T.poison + T.sl_gas + T.n2
turf_total = max(turf_total, 1)
var/t1 = turf_total / CELLSTANDARD * 100
if (!( (90 < t1 && t1 < 110) ))
safe = 0
t1 = T.oxygen / turf_total * 100
if (!( (20 < t1 && t1 < 30) ))
safe = 0
src.icon_state = text("alarm:[]", !( safe ))
return
// Called when area power status changes. Alarms use the ENVIRON channel
power_change()
if( powered(ENVIRON) )
stat &= ~NOPOWER
else
stat |= NOPOWER
// Examining an alarm provides an air quality readout the same as a handheld air analyzer
examine()
set src in oview(1)
if (usr.stat || stat & NOPOWER)
return
if ((!( istype(usr, /mob/human) ) && (!( ticker ) || (ticker && ticker.mode != "monkey"))))
if (!istype(usr, /mob/ai) && !istype(usr, /mob/drone))
usr.client_mob() << "\red You don't have the dexterity to do this!"
return
var/turf/T = src.loc
if (!( istype(T, /turf) ))
return
var/turf_total = T.co2 + T.oxygen + T.poison + T.sl_gas + T.n2
turf_total = max(turf_total, 1)
usr.show_message("\blue <B>Results:</B>", 1)
var/t = ""
var/t1 = turf_total / CELLSTANDARD * 100
if ((90 < t1 && t1 < 110))
usr.show_message(text("\blue Air Pressure: []%", t1), 1)
else
usr.show_message(text("\blue Air Pressure:\red []%", t1), 1)
t1 = T.n2 / turf_total * 100
t1 = round(t1, 0.0010)
if ((60 < t1 && t1 < 80))
t += text("<font color=blue>Nitrogen: []</font> ", t1)
else
t += text("<font color=red>Nitrogen: []</font> ", t1)
t1 = T.oxygen / turf_total * 100
t1 = round(t1, 0.0010)
if ((20 < t1 && t1 < 24))
t += text("<font color=blue>Oxygen: []</font> ", t1)
else
t += text("<font color=red>Oxygen: []</font> ", t1)
t1 = T.poison / turf_total * 100
t1 = round(t1, 0.0010)
if (t1 < 0.5)
t += text("<font color=blue>Plasma: []</font> ", t1)
else
t += text("<font color=red>Plasma: []</font> ", t1)
t1 = T.co2 / turf_total * 100
t1 = round(t1, 0.0010)
if (t1 < 1)
t += text("<font color=blue>CO2: []</font> ", t1)
else
t += text("<font color=red>CO2: []</font> ", t1)
t1 = T.sl_gas / turf_total * 100
t1 = round(t1, 0.0010)
if (t1 < 5)
t += text("<font color=blue>NO2: []</font>", t1)
else
t += text("<font color=red>NO2: []</font>", t1)
usr.show_message(t, 1)
usr.show_message(text("\blue \t Temperature: []&deg;C", T.temp - T0C), 1)
src.add_fingerprint(usr)
return
/**
* Indicator -- Subtype of alarm, used to indicated air quality in the airtunnel
*
*/
obj/machinery/alarm/indicator
name = "indicator"
icon = 'airtunnel.dmi'
icon_state = "indicator"
// Monitors location air quality and changes icon_state to reflect it
// Also sets airtunnel datum air status
process()
if(stat & NOPOWER)
icon_state = "indicator-p"
return
var/safe = 1
var/turf/T = src.loc
if (!( istype(T, /turf) ))
return
if (locate(/obj/move, T))
T = locate(/obj/move, T)
var/turf_total = T.co2 + T.oxygen + T.poison + T.sl_gas + T.n2
turf_total = max(turf_total, 1)
var/t1 = turf_total / CELLSTANDARD * 100
if (!( (90 < t1 && t1 < 110) ))
safe = 0
t1 = T.oxygen / turf_total * 100
if (!( (20 < t1 && t1 < 30) ))
safe = 0
src.icon_state = text("indicator[]", safe)
SS13_airtunnel.air_stat = safe
return