* Pipe Misc -- Global procs and support routines used in pipe network calculations.
|
|
*
|
|
*/
|
|
|
|
|
|
// Build the list of pipeline objects. Called after world has loaded.
|
|
|
|
/proc/makepipelines()
|
|
|
|
|
|
for(var/obj/machinery/pipes/P in machines) // look for a pipe
|
|
|
|
if(!P.pl) // if not already part of a line
|
|
var/obj/machinery/pipeline/PL = new() // make a new pipeline
|
|
plines += PL // add it to the global list
|
|
P.buildnodes(PL) // and spread to all connected pipes
|
|
|
|
// After the above, all pipes in the world will be associated with a pipeline object
|
|
|
|
// Now set pipeline names (so they can be distinguished for debugging).
|
|
|
|
for(var/L = 1 to length(plines)) // for count of lines found
|
|
var/obj/machinery/pipeline/PL = plines[L] // get the pipeline virtual object
|
|
PL.name = "pipeline #[L]" // and set the name
|
|
|
|
// Next, find the pipes at the end of each pipeline, and use those to get an ordered list of all pipes in the pipeline
|
|
// Then set the pipeline variables
|
|
|
|
for(var/obj/machinery/pipes/P in machines) // look for pipes
|
|
|
|
if(P.termination) // true if pipe is terminated (ends in blank or a machine)
|
|
var/obj/machinery/pipeline/PL = P.pl // get the pipeline from the pipe's pl
|
|
|
|
var/list/pipes = pipelist(null, P) // get a list of pipes from P until terminated
|
|
|
|
PL.nodes = pipes // pipeline is this list of nodes
|
|
PL.numnodes = pipes.len // with this many nodes
|
|
PL.capmult = PL.numnodes+1 // with this flow multiplier
|
|
|
|
|
|
// Now set the node connections for all machines that connect to pipelines.
|
|
|
|
for(var/obj/machinery/M in machines) // for all machines
|
|
if(M.p_dir || M.h_dir) // which are pipe-connected
|
|
if(!M.ispipe()) // is not a pipe itself
|
|
M.buildnodes() // build the nodes, setting the links to the pipelines
|
|
// also sets the vnodes for the pipelines
|
|
|
|
// Finally, make sure the pipeline nodes point to the terminating machines.
|
|
|
|
for(var/obj/machinery/pipeline/PL in plines) // for all lines
|
|
PL.setterm() // orient the pipes and set the pipeline vnodes to the terminating machines
|
|
|
|
|
|
|
|
// Return a list of pipes, in order of connection
|
|
// Starting at startnode, moving away from source
|
|
|
|
/proc/pipelist(var/obj/machinery/source, var/obj/machinery/startnode)
|
|
|
|
var/list/L = list()
|
|
|
|
var/obj/machinery/node = startnode
|
|
var/obj/machinery/prev = source
|
|
var/obj/machinery/newnode
|
|
|
|
while(node)
|
|
L += node
|
|
newnode = node.next(prev)
|
|
prev = node
|
|
|
|
if(newnode && newnode.ispipe())
|
|
node = newnode
|
|
else
|
|
break
|
|
|
|
return L
|
|
|
|
|
|
// Returns the machine with compatible p_dir and level in 1 step in dir mdir from turf S
|
|
// Note: "compatible" means the machine has a p_dir pointing towards S.
|
|
// Returns null if no such machine is found
|
|
|
|
/proc/get_machine(var/level, var/turf/S, var/mdir)
|
|
|
|
var/flip = turn(mdir, 180)
|
|
|
|
var/turf/T = get_step(S, mdir)
|
|
|
|
for(var/obj/machinery/M in T.contents)
|
|
if(M.level == level)
|
|
if(M.p_dir & flip)
|
|
return M
|
|
|
|
return null
|
|
|
|
|
|
// Returns the machine with compatible h_dir and level in 1 step in dir mdir from turf S
|
|
// Same as routine above, but for h/e rather than standard pipe.
|
|
|
|
/proc/get_he_machine(var/level, var/turf/S, mdir)
|
|
|
|
var/flip = turn(mdir, 180)
|
|
|
|
var/turf/T = get_step(S, mdir)
|
|
|
|
for(var/obj/machinery/M in T.contents)
|
|
if(M.level == level)
|
|
if(M.h_dir & flip)
|
|
return M
|
|
|
|
return null
|
|
|
|
|
|
// The main flow routine
|
|
// Calculates the movement of "amount" gas between source and target machines
|
|
// If amount is negative, flow is from source to target, and source gas level is reduced
|
|
// If amount is positive, flow is from target to source, and source gas level is increased by a fraction of the target gas
|
|
// The source's new gas level is stored in "sngas", which replaces the actual gas level in the gas_flow() proc for this machine.
|
|
// Note the target's gas level isn't altered here; it will run this proc itself and alter it's own gas levels by the correct amount.
|
|
|
|
|
|
/proc/calc_delta(obj/machinery/source, obj/substance/gas/sgas, obj/substance/gas/sngas, obj/machinery/target, amount)
|
|
|
|
var/obj/substance/gas/tgas = target.get_gas(source)
|
|
|
|
var/obj/substance/gas/ndelta = new()
|
|
|
|
if(amount < 0) // then flowing from source to target
|
|
|
|
ndelta.set_frac(sgas, -amount) // this is fraction of the gas which will be transfered to other node
|
|
sngas.sub_delta(ndelta) // subtract off the fraction which is gone
|
|
|
|
else // flowing from target to source
|
|
ndelta.set_frac(tgas, amount) // fraction of gas from the other node
|
|
sngas.add_delta(ndelta) // add the fraction to the new gas resv
|
|
|
|
|
|
// Called by all gas-handling machines when a pipe node is not present.
|
|
// Also used by /obj/machinery/inlet
|
|
// Calculates a leak between a gas reservoir (sgas, sngas) and turf T
|
|
// Gas can flow both ways, if pipe is less full than the turf
|
|
|
|
|
|
/obj/machinery/proc/flow_to_turf(var/obj/substance/gas/sgas, var/obj/substance/gas/sngas, var/turf/T)
|
|
|
|
|
|
|
|
var/t_tot = T.tot_gas() * 0.2 // partial pressure of turf gas at pipe, for the moment
|
|
|
|
var/delta_gt = FLOWFRAC * ( t_tot - sgas.tot_gas() / capmult )
|
|
|
|
|
|
var/obj/substance/gas/ndelta = new()
|
|
|
|
if(delta_gt < 0) // flow from pipe to turf
|
|
|
|
ndelta.set_frac(sgas, -delta_gt) // ndelta contains gas to transfer to turf
|
|
sngas.sub_delta(ndelta) // update new gas to remove the amount transfered
|
|
ndelta.turf_add(T, -1) // add all of ndelta to turf
|
|
|
|
else // flow from turf to pipe
|
|
|
|
sngas.turf_take(T, delta_gt) // grab gas from turf and direcly add it to the new gas
|
|
|
|
T.res_vars() // update turf gas vars for both cases
|
|
|
|
|
|
|