Merge pull request #1708 from Markolie/caching

Caching
This commit is contained in:
TheDZD
2015-08-11 17:42:57 -04:00
14 changed files with 194 additions and 103 deletions
+1 -8
View File
@@ -31,14 +31,7 @@
/datum/nano_module/atmos_control/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
var/data[0]
var/alarms[0]
// TODO: Move these to a cache, similar to cameras
for(var/obj/machinery/alarm/alarm in sortAtom((monitored_alarms.len ? monitored_alarms : machines)))
if(!monitored_alarms.len && alarm.z != ZLEVEL_STATION && alarm.z != ZLEVEL_ASTEROID)
continue
alarms[++alarms.len] = alarm.get_nano_data_console()
data["alarms"] = alarms
data["alarms"] = air_alarm_repository.air_alarm_data(monitored_alarms)
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
if(!ui)
+2 -49
View File
@@ -1,6 +1,5 @@
/datum/nano_module/crew_monitor
name = "Crew monitor"
var/list/tracked = new
/datum/nano_module/crew_monitor/Topic(href, href_list)
if(..())
@@ -18,51 +17,12 @@
return 1
/datum/nano_module/crew_monitor/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1, var/datum/topic_state/state = default_state)
src.scan()
var/data[0]
var/turf/T = get_turf(nano_host())
var/list/crewmembers = list()
for(var/obj/item/clothing/under/C in src.tracked)
var/turf/pos = get_turf(C)
if((C) && (C.has_sensor) && (pos) && (T && pos.z == T.z) && (C.sensor_mode != SUIT_SENSOR_OFF))
if(istype(C.loc, /mob/living/carbon/human))
var/mob/living/carbon/human/H = C.loc
if(H.w_uniform != C)
continue
var/list/crewmemberData = list("dead"=0, "oxy"=-1, "tox"=-1, "fire"=-1, "brute"=-1, "area"="", "x"=-1, "y"=-1)
crewmemberData["reference"] = "\ref[H]"
crewmemberData["sensor_type"] = C.sensor_mode
crewmemberData["name"] = H.get_authentification_name(if_no_id="Unknown")
crewmemberData["rank"] = H.get_authentification_rank(if_no_id="Unknown", if_no_job="No Job")
crewmemberData["assignment"] = H.get_assignment(if_no_id="Unknown", if_no_job="No Job")
if(C.sensor_mode >= SUIT_SENSOR_BINARY)
crewmemberData["dead"] = H.stat > 1
if(C.sensor_mode >= SUIT_SENSOR_VITAL)
crewmemberData["oxy"] = round(H.getOxyLoss(), 1)
crewmemberData["tox"] = round(H.getToxLoss(), 1)
crewmemberData["fire"] = round(H.getFireLoss(), 1)
crewmemberData["brute"] = round(H.getBruteLoss(), 1)
if(C.sensor_mode >= SUIT_SENSOR_TRACKING)
var/area/A = get_area(H)
crewmemberData["area"] = sanitize(A.name)
crewmemberData["x"] = pos.x
crewmemberData["y"] = pos.y
crewmembers[++crewmembers.len] = crewmemberData
crewmembers = sortByKey(crewmembers, "name")
data["isAI"] = isAI(user)
data["crewmembers"] = crewmembers
data["crewmembers"] = crew_repository.health_data(T)
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
if(!ui)
@@ -78,11 +38,4 @@
// should make the UI auto-update; doesn't seem to?
ui.set_auto_update(1)
/datum/nano_module/crew_monitor/proc/scan()
for(var/mob/living/carbon/human/H in mob_list)
if(istype(H.w_uniform, /obj/item/clothing/under))
var/obj/item/clothing/under/C = H.w_uniform
if (C.has_sensor)
tracked |= C
return 1
+8 -22
View File
@@ -13,34 +13,20 @@
/datum/nano_module/power_monitor/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1, var/datum/topic_state/state = default_state)
var/data[0]
var/pMonData[0]
var/apcData[0]
data["powermonitor"] = powermonitor
if(select_monitor)
data["select_monitor"] = 1
for(var/obj/machinery/computer/monitor/pMon in world)
if( !(pMon.stat & (NOPOWER|BROKEN)) )
pMonData[++pMonData.len] = list ("Name" = pMon.name, "ref" = "\ref[pMon]")
data["powermonitors"] = powermonitor_repository.powermonitor_data()
data["powermonitors"] = pMonData
if (powermonitor && !isnull(powermonitor.powernet))
if (powermonitor && !isnull(powermonitor.powernet))
if(select_monitor && (powermonitor.stat & (NOPOWER|BROKEN)))
powermonitor = null
return
data["poweravail"] = powermonitor.powernet.avail
data["powerload"] = num2text(powermonitor.powernet.viewload,10)
var/list/L = list()
for(var/obj/machinery/power/terminal/term in powermonitor.powernet.nodes)
if(istype(term.master, /obj/machinery/power/apc))
var/obj/machinery/power/apc/A = term.master
L += A
var/list/Status = list(0,0,1,1) // Status: off, auto-off, on, auto-on
var/list/chg = list(0,1,1) // Charging: nope, charging, full
for(var/obj/machinery/power/apc/A in L)
apcData[++apcData.len] = list("Name" = html_encode(A.area.name), "Equipment" = Status[A.equipment+1], "Lights" = Status[A.lighting+1], "Environment" = Status[A.environ+1], "CellPct" = A.cell ? round(A.cell.percent(),1) : -1, "CellStatus" = A.cell ? chg[A.charging+1] : 0)
data["apcs"] = apcData
data["powerload"] = num2text(powermonitor.powernet.viewload,10)
data["apcs"] = apc_repository.apc_data(powermonitor)
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
if (!ui)
ui = new(user, src, ui_key, "power_monitor.tmpl", "Power Monitoring Console", 800, 700, state = state)