Ports Nano UI to Subsystems

This commit is contained in:
Fox McCloud
2018-03-26 23:59:52 -04:00
parent c13ce9099f
commit 5701ea7c75
122 changed files with 398 additions and 375 deletions
@@ -137,7 +137,7 @@
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = nanomanager.try_update_ui(user, src, ui_key, ui, force_open)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
@@ -174,7 +174,7 @@
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
nanomanager.update_uis(src)
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/passive_gate/attackby(obj/item/weapon/W, mob/user, params)
if(!istype(W, /obj/item/weapon/wrench))
@@ -157,7 +157,7 @@ Thus, the two variables affect pump operation are set in New():
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = nanomanager.try_update_ui(user, src, ui_key, ui, force_open)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
@@ -194,7 +194,7 @@ Thus, the two variables affect pump operation are set in New():
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
nanomanager.update_uis(src)
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/pump/power_change()
var/old_stat = stat
@@ -147,7 +147,7 @@ Thus, the two variables affect pump operation are set in New():
/obj/machinery/atmospherics/binary/volume_pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = nanomanager.try_update_ui(user, src, ui_key, ui, force_open)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 310, 115, state = state)
ui.open()
@@ -184,7 +184,7 @@ Thus, the two variables affect pump operation are set in New():
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", "atmos")
update_icon()
nanomanager.update_uis(src)
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/volume_pump/power_change()
var/old_stat = stat