CRLF to LF

This commit is contained in:
SteelSlayer
2020-03-18 12:56:15 -05:00
parent 13d3f3239b
commit 59680db186
11 changed files with 3623 additions and 3623 deletions
@@ -1,269 +1,269 @@
/obj/machinery/atmospherics/binary/dp_vent_pump
icon = 'icons/atmos/vent_pump.dmi'
icon_state = "map_dp_vent"
//node2 is output port
//node1 is input port
req_one_access_txt = "24;10"
name = "dual-port air vent"
desc = "Has a valve and pump attached to it. There are two ports."
can_unwrench = 1
level = 1
connect_types = list(1,2,3) //connects to regular, supply and scrubbers pipes
var/on = 0
var/pump_direction = 1 //0 = siphoning, 1 = releasing
var/external_pressure_bound = ONE_ATMOSPHERE
var/input_pressure_min = 0
var/output_pressure_max = 0
var/frequency = ATMOS_VENTSCRUB
var/id_tag = null
var/datum/radio_frequency/radio_connection
var/advcontrol = 0//does this device listen to the AAC
settagwhitelist = list("id_tag")
var/pressure_checks = 1
//1: Do not pass external_pressure_bound
//2: Do not pass input_pressure_min
//4: Do not pass output_pressure_max
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
..()
if(!id_tag)
assign_uid()
id_tag = num2text(uid)
icon = null
/obj/machinery/atmospherics/binary/dp_vent_pump/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/dp_vent_pump/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
name = "large dual port air vent"
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/on
on = TRUE
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
..()
air1.volume = 1000
air2.volume = 1000
/obj/machinery/atmospherics/binary/volume_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
..()
if(!check_icon_cache())
return
overlays.Cut()
var/vent_icon = "vent"
var/turf/T = get_turf(src)
if(!istype(T))
return
if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
vent_icon += "h"
if(!powered())
vent_icon += "off"
else
vent_icon += "[on ? "[pump_direction ? "out" : "in"]" : "off"]"
overlays += GLOB.pipe_icon_manager.get_atmos_icon("device", , , vent_icon)
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
return
else
if(node1)
add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type)
else
add_underlay(T, node1, turn(dir, -180))
if(node2)
add_underlay(T, node2, dir, node2.icon_connect_type)
else
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/dp_vent_pump/process_atmos()
..()
if(!on)
return 0
var/datum/gas_mixture/environment = loc.return_air()
var/environment_pressure = environment.return_pressure()
if(pump_direction) //input -> external
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure))
if(pressure_checks&2)
pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min))
if(pressure_delta > 0)
if(air1.temperature > 0)
var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
loc.assume_air(removed)
parent1.update = 1
air_update_turf()
else //external -> output
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound))
if(pressure_checks&4)
pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure()))
if(pressure_delta > 0)
if(environment.temperature > 0)
var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = loc.remove_air(transfer_moles)
air2.merge(removed)
parent2.update = 1
air_update_turf()
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/dp_vent_pump/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id_tag,
"device" = "ADVP",
"power" = on,
"direction" = pump_direction?("release"):("siphon"),
"checks" = pressure_checks,
"input" = input_pressure_min,
"output" = output_pressure_max,
"external" = external_pressure_bound,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command") || (signal.data["advcontrol"] && !advcontrol))
return 0
if(signal.data["power"] != null)
on = text2num(signal.data["power"])
if(signal.data["power_toggle"] != null)
on = !on
if(signal.data["direction"] != null)
pump_direction = text2num(signal.data["direction"])
if(signal.data["checks"] != null)
pressure_checks = text2num(signal.data["checks"])
if(signal.data["purge"])
pressure_checks &= ~1
pump_direction = 0
if(signal.data["stabilize"])//the fact that this was "stabalize" shows how many fucks people give about these wonders, none
pressure_checks |= 1
pump_direction = 1
if(signal.data["set_input_pressure"] != null)
input_pressure_min = between(
0,
text2num(signal.data["set_input_pressure"]),
ONE_ATMOSPHERE*50
)
if(signal.data["set_output_pressure"] != null)
output_pressure_max = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(signal.data["set_external_pressure"] != null)
external_pressure_bound = between(
0,
text2num(signal.data["set_external_pressure"]),
ONE_ATMOSPHERE*50
)
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
/obj/machinery/atmospherics/binary/dp_vent_pump/attackby(var/obj/item/W as obj, var/mob/user as mob)
if(istype(W, /obj/item/multitool))
update_multitool_menu(user)
return 1
return ..()
/obj/machinery/atmospherics/binary/dp_vent_pump/multitool_menu(var/mob/user,var/obj/item/multitool/P)
return {"
<ul>
<li><b>Frequency:</b> <a href="?src=[UID()];set_freq=-1">[format_frequency(frequency)] GHz</a> (<a href="?src=[UID()];set_freq=[ATMOS_VENTSCRUB]">Reset</a>)</li>
<li><b>ID Tag:</b> <a href="?src=[UID()];set_id=1">[id_tag]</a></li>
<li><b>AAC Acces:</b> <a href="?src=[UID()];toggleadvcontrol=1">[advcontrol ? "Allowed" : "Blocked"]</a></li>
</ul>
"}
/obj/machinery/atmospherics/binary/dp_vent_pump/multitool_topic(var/mob/user, var/list/href_list, var/obj/O)
. = ..()
if(.)
return .
if("toggleadvcontrol" in href_list)
advcontrol = !advcontrol
return TRUE
/obj/machinery/atmospherics/binary/dp_vent_pump
icon = 'icons/atmos/vent_pump.dmi'
icon_state = "map_dp_vent"
//node2 is output port
//node1 is input port
req_one_access_txt = "24;10"
name = "dual-port air vent"
desc = "Has a valve and pump attached to it. There are two ports."
can_unwrench = 1
level = 1
connect_types = list(1,2,3) //connects to regular, supply and scrubbers pipes
var/on = 0
var/pump_direction = 1 //0 = siphoning, 1 = releasing
var/external_pressure_bound = ONE_ATMOSPHERE
var/input_pressure_min = 0
var/output_pressure_max = 0
var/frequency = ATMOS_VENTSCRUB
var/id_tag = null
var/datum/radio_frequency/radio_connection
var/advcontrol = 0//does this device listen to the AAC
settagwhitelist = list("id_tag")
var/pressure_checks = 1
//1: Do not pass external_pressure_bound
//2: Do not pass input_pressure_min
//4: Do not pass output_pressure_max
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
..()
if(!id_tag)
assign_uid()
id_tag = num2text(uid)
icon = null
/obj/machinery/atmospherics/binary/dp_vent_pump/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/dp_vent_pump/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
name = "large dual port air vent"
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/on
on = TRUE
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
..()
air1.volume = 1000
air2.volume = 1000
/obj/machinery/atmospherics/binary/volume_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
..()
if(!check_icon_cache())
return
overlays.Cut()
var/vent_icon = "vent"
var/turf/T = get_turf(src)
if(!istype(T))
return
if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
vent_icon += "h"
if(!powered())
vent_icon += "off"
else
vent_icon += "[on ? "[pump_direction ? "out" : "in"]" : "off"]"
overlays += GLOB.pipe_icon_manager.get_atmos_icon("device", , , vent_icon)
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
return
else
if(node1)
add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type)
else
add_underlay(T, node1, turn(dir, -180))
if(node2)
add_underlay(T, node2, dir, node2.icon_connect_type)
else
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/dp_vent_pump/process_atmos()
..()
if(!on)
return 0
var/datum/gas_mixture/environment = loc.return_air()
var/environment_pressure = environment.return_pressure()
if(pump_direction) //input -> external
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure))
if(pressure_checks&2)
pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min))
if(pressure_delta > 0)
if(air1.temperature > 0)
var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
loc.assume_air(removed)
parent1.update = 1
air_update_turf()
else //external -> output
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound))
if(pressure_checks&4)
pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure()))
if(pressure_delta > 0)
if(environment.temperature > 0)
var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = loc.remove_air(transfer_moles)
air2.merge(removed)
parent2.update = 1
air_update_turf()
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/dp_vent_pump/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id_tag,
"device" = "ADVP",
"power" = on,
"direction" = pump_direction?("release"):("siphon"),
"checks" = pressure_checks,
"input" = input_pressure_min,
"output" = output_pressure_max,
"external" = external_pressure_bound,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command") || (signal.data["advcontrol"] && !advcontrol))
return 0
if(signal.data["power"] != null)
on = text2num(signal.data["power"])
if(signal.data["power_toggle"] != null)
on = !on
if(signal.data["direction"] != null)
pump_direction = text2num(signal.data["direction"])
if(signal.data["checks"] != null)
pressure_checks = text2num(signal.data["checks"])
if(signal.data["purge"])
pressure_checks &= ~1
pump_direction = 0
if(signal.data["stabilize"])//the fact that this was "stabalize" shows how many fucks people give about these wonders, none
pressure_checks |= 1
pump_direction = 1
if(signal.data["set_input_pressure"] != null)
input_pressure_min = between(
0,
text2num(signal.data["set_input_pressure"]),
ONE_ATMOSPHERE*50
)
if(signal.data["set_output_pressure"] != null)
output_pressure_max = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(signal.data["set_external_pressure"] != null)
external_pressure_bound = between(
0,
text2num(signal.data["set_external_pressure"]),
ONE_ATMOSPHERE*50
)
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
/obj/machinery/atmospherics/binary/dp_vent_pump/attackby(var/obj/item/W as obj, var/mob/user as mob)
if(istype(W, /obj/item/multitool))
update_multitool_menu(user)
return 1
return ..()
/obj/machinery/atmospherics/binary/dp_vent_pump/multitool_menu(var/mob/user,var/obj/item/multitool/P)
return {"
<ul>
<li><b>Frequency:</b> <a href="?src=[UID()];set_freq=-1">[format_frequency(frequency)] GHz</a> (<a href="?src=[UID()];set_freq=[ATMOS_VENTSCRUB]">Reset</a>)</li>
<li><b>ID Tag:</b> <a href="?src=[UID()];set_id=1">[id_tag]</a></li>
<li><b>AAC Acces:</b> <a href="?src=[UID()];toggleadvcontrol=1">[advcontrol ? "Allowed" : "Blocked"]</a></li>
</ul>
"}
/obj/machinery/atmospherics/binary/dp_vent_pump/multitool_topic(var/mob/user, var/list/href_list, var/obj/O)
. = ..()
if(.)
return .
if("toggleadvcontrol" in href_list)
advcontrol = !advcontrol
return TRUE
@@ -1,192 +1,192 @@
/obj/machinery/atmospherics/binary/passive_gate
//Tries to achieve target pressure at output (like a normal pump) except
// Uses no power but can not transfer gases from a low pressure area to a high pressure area
icon = 'icons/atmos/passive_gate.dmi'
icon_state = "map"
name = "passive gate"
desc = "A one-way air valve that does not require power"
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/passive_gate/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/passive_gate/update_icon()
..()
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/passive_gate/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, 180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/passive_gate/process_atmos()
..()
if(!on)
return 0
var/output_starting_pressure = air2.return_pressure()
var/input_starting_pressure = air1.return_pressure()
if(output_starting_pressure >= min(target_pressure,input_starting_pressure-10))
//No need to pump gas if target is already reached or input pressure is too low
//Need at least 10 KPa difference to overcome friction in the mechanism
return 1
//Calculate necessary moles to transfer using PV = nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = min(target_pressure - output_starting_pressure, (input_starting_pressure - output_starting_pressure)/2)
//Can not have a pressure delta that would cause output_pressure > input_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/passive_gate/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/passive_gate/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/passive_gate/attackby(obj/item/W, mob/user, params)
if(!istype(W, /obj/item/wrench))
return ..()
if(on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()
/obj/machinery/atmospherics/binary/passive_gate
//Tries to achieve target pressure at output (like a normal pump) except
// Uses no power but can not transfer gases from a low pressure area to a high pressure area
icon = 'icons/atmos/passive_gate.dmi'
icon_state = "map"
name = "passive gate"
desc = "A one-way air valve that does not require power"
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/passive_gate/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/passive_gate/update_icon()
..()
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/passive_gate/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, 180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/passive_gate/process_atmos()
..()
if(!on)
return 0
var/output_starting_pressure = air2.return_pressure()
var/input_starting_pressure = air1.return_pressure()
if(output_starting_pressure >= min(target_pressure,input_starting_pressure-10))
//No need to pump gas if target is already reached or input pressure is too low
//Need at least 10 KPa difference to overcome friction in the mechanism
return 1
//Calculate necessary moles to transfer using PV = nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = min(target_pressure - output_starting_pressure, (input_starting_pressure - output_starting_pressure)/2)
//Can not have a pressure delta that would cause output_pressure > input_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/passive_gate/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/passive_gate/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/passive_gate/attackby(obj/item/W, mob/user, params)
if(!istype(W, /obj/item/wrench))
return ..()
if(on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()
@@ -1,261 +1,261 @@
/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/binary/pump
icon = 'icons/atmos/pump.dmi'
icon_state = "map_off"
name = "gas pump"
desc = "A pump"
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/pump/CtrlClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
toggle()
return ..()
/obj/machinery/atmospherics/binary/pump/AICtrlClick()
toggle()
return ..()
/obj/machinery/atmospherics/binary/pump/AltClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
set_max()
return
/obj/machinery/atmospherics/binary/pump/AIAltClick()
set_max()
return ..()
/obj/machinery/atmospherics/binary/pump/proc/toggle()
if(powered())
on = !on
update_icon()
/obj/machinery/atmospherics/binary/pump/proc/set_max()
if(powered())
target_pressure = MAX_OUTPUT_PRESSURE
update_icon()
/obj/machinery/atmospherics/binary/pump/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/pump/on
icon_state = "map_on"
on = 1
/obj/machinery/atmospherics/binary/pump/update_icon()
..()
if(!powered())
icon_state = "off"
else
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/pump/process_atmos()
..()
if((stat & (NOPOWER|BROKEN)) || !on)
return 0
var/output_starting_pressure = air2.return_pressure()
if( (target_pressure - output_starting_pressure) < 0.01)
//No need to pump gas if target is already reached!
return 1
//Calculate necessary moles to transfer using PV=nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = target_pressure - output_starting_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/pump/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/pump/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if(signal.data["power"])
on = text2num(signal.data["power"])
if(signal.data["power_toggle"])
on = !on
if(signal.data["set_output_pressure"])
target_pressure = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/binary/pump/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/pump/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/pump/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/pump/power_change()
var/old_stat = stat
..()
if(old_stat != stat)
update_icon()
/obj/machinery/atmospherics/binary/pump/attackby(obj/item/W, mob/user, params)
if(istype(W, /obj/item/pen))
var/t = copytext(stripped_input(user, "Enter the name for the pump.", "Rename", name), 1, MAX_NAME_LEN)
if(!t)
return
if(!in_range(src, usr) && loc != usr)
return
name = t
return
else if(!istype(W, /obj/item/wrench))
return ..()
if(!(stat & NOPOWER) && on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()
/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/binary/pump
icon = 'icons/atmos/pump.dmi'
icon_state = "map_off"
name = "gas pump"
desc = "A pump"
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/pump/CtrlClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
toggle()
return ..()
/obj/machinery/atmospherics/binary/pump/AICtrlClick()
toggle()
return ..()
/obj/machinery/atmospherics/binary/pump/AltClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
set_max()
return
/obj/machinery/atmospherics/binary/pump/AIAltClick()
set_max()
return ..()
/obj/machinery/atmospherics/binary/pump/proc/toggle()
if(powered())
on = !on
update_icon()
/obj/machinery/atmospherics/binary/pump/proc/set_max()
if(powered())
target_pressure = MAX_OUTPUT_PRESSURE
update_icon()
/obj/machinery/atmospherics/binary/pump/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/pump/on
icon_state = "map_on"
on = 1
/obj/machinery/atmospherics/binary/pump/update_icon()
..()
if(!powered())
icon_state = "off"
else
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/pump/process_atmos()
..()
if((stat & (NOPOWER|BROKEN)) || !on)
return 0
var/output_starting_pressure = air2.return_pressure()
if( (target_pressure - output_starting_pressure) < 0.01)
//No need to pump gas if target is already reached!
return 1
//Calculate necessary moles to transfer using PV=nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = target_pressure - output_starting_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/pump/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/pump/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if(signal.data["power"])
on = text2num(signal.data["power"])
if(signal.data["power_toggle"])
on = !on
if(signal.data["set_output_pressure"])
target_pressure = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/binary/pump/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/pump/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/pump/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/pump/power_change()
var/old_stat = stat
..()
if(old_stat != stat)
update_icon()
/obj/machinery/atmospherics/binary/pump/attackby(obj/item/W, mob/user, params)
if(istype(W, /obj/item/pen))
var/t = copytext(stripped_input(user, "Enter the name for the pump.", "Rename", name), 1, MAX_NAME_LEN)
if(!t)
return
if(!in_range(src, usr) && loc != usr)
return
name = t
return
else if(!istype(W, /obj/item/wrench))
return ..()
if(!(stat & NOPOWER) && on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()
@@ -1,257 +1,257 @@
/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/binary/volume_pump
icon = 'icons/atmos/volume_pump.dmi'
icon_state = "map_off"
name = "volumetric gas pump"
desc = "A volumetric pump"
can_unwrench = 1
var/on = 0
var/transfer_rate = 200
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/volume_pump/CtrlClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
toggle()
return ..()
/obj/machinery/atmospherics/binary/volume_pump/AICtrlClick()
toggle()
return ..()
/obj/machinery/atmospherics/binary/volume_pump/AltClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
set_max()
return
/obj/machinery/atmospherics/binary/volume_pump/AIAltClick()
set_max()
return ..()
/obj/machinery/atmospherics/binary/volume_pump/proc/toggle()
if(powered())
on = !on
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/proc/set_max()
if(powered())
transfer_rate = MAX_TRANSFER_RATE
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/volume_pump/on
on = 1
icon_state = "map_on"
/obj/machinery/atmospherics/binary/volume_pump/atmos_init()
..()
set_frequency(frequency)
/obj/machinery/atmospherics/binary/volume_pump/update_icon()
..()
if(!powered())
icon_state = "off"
else
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/volume_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/volume_pump/process_atmos()
..()
if((stat & (NOPOWER|BROKEN)) || !on)
return 0
// Pump mechanism just won't do anything if the pressure is too high/too low
var/input_starting_pressure = air1.return_pressure()
var/output_starting_pressure = air2.return_pressure()
if((input_starting_pressure < 0.01) || (output_starting_pressure > 9000))
return 1
var/transfer_ratio = max(1, transfer_rate/air1.volume)
var/datum/gas_mixture/removed = air1.remove_ratio(transfer_ratio)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
/obj/machinery/atmospherics/binary/volume_pump/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency)
/obj/machinery/atmospherics/binary/volume_pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "APV",
"power" = on,
"transfer_rate" = transfer_rate,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal)
return 1
/obj/machinery/atmospherics/binary/volume_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if(signal.data["power"])
on = text2num(signal.data["power"])
if(signal.data["power_toggle"])
on = !on
if(signal.data["set_transfer_rate"])
transfer_rate = between(
0,
text2num(signal.data["set_transfer_rate"]),
air1.volume
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/volume_pump/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/volume_pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 310, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/volume_pump/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["rate"] = round(transfer_rate)
data["max_rate"] = round(MAX_TRANSFER_RATE)
return data
/obj/machinery/atmospherics/binary/volume_pump/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["rate"])
var/rate = href_list["rate"]
if(rate == "max")
rate = MAX_TRANSFER_RATE
. = TRUE
else if(rate == "input")
rate = input("New transfer rate (0-[MAX_TRANSFER_RATE] L/s):", name, transfer_rate) as num|null
if(!isnull(rate))
. = TRUE
else if(text2num(rate) != null)
rate = text2num(rate)
. = TRUE
if(.)
transfer_rate = Clamp(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/volume_pump/power_change()
var/old_stat = stat
..()
if(old_stat != stat)
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/attackby(obj/item/W, mob/user, params)
if(istype(W, /obj/item/pen))
var/t = copytext(stripped_input(user, "Enter the name for the volume pump.", "Rename", name), 1, MAX_NAME_LEN)
if(!t)
return
if(!in_range(src, usr) && loc != usr)
return
name = t
return
else if(!istype(W, /obj/item/wrench))
return ..()
if(!(stat & NOPOWER) && on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()
/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/binary/volume_pump
icon = 'icons/atmos/volume_pump.dmi'
icon_state = "map_off"
name = "volumetric gas pump"
desc = "A volumetric pump"
can_unwrench = 1
var/on = 0
var/transfer_rate = 200
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/volume_pump/CtrlClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
toggle()
return ..()
/obj/machinery/atmospherics/binary/volume_pump/AICtrlClick()
toggle()
return ..()
/obj/machinery/atmospherics/binary/volume_pump/AltClick(mob/living/user)
if(!istype(user) || user.incapacitated())
to_chat(user, "<span class='warning'>You can't do that right now!</span>")
return
if(!in_range(src, user) && !issilicon(usr))
return
if(!ishuman(usr) && !issilicon(usr))
return
set_max()
return
/obj/machinery/atmospherics/binary/volume_pump/AIAltClick()
set_max()
return ..()
/obj/machinery/atmospherics/binary/volume_pump/proc/toggle()
if(powered())
on = !on
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/proc/set_max()
if(powered())
transfer_rate = MAX_TRANSFER_RATE
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/Destroy()
if(SSradio)
SSradio.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/volume_pump/on
on = 1
icon_state = "map_on"
/obj/machinery/atmospherics/binary/volume_pump/atmos_init()
..()
set_frequency(frequency)
/obj/machinery/atmospherics/binary/volume_pump/update_icon()
..()
if(!powered())
icon_state = "off"
else
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/volume_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/volume_pump/process_atmos()
..()
if((stat & (NOPOWER|BROKEN)) || !on)
return 0
// Pump mechanism just won't do anything if the pressure is too high/too low
var/input_starting_pressure = air1.return_pressure()
var/output_starting_pressure = air2.return_pressure()
if((input_starting_pressure < 0.01) || (output_starting_pressure > 9000))
return 1
var/transfer_ratio = max(1, transfer_rate/air1.volume)
var/datum/gas_mixture/removed = air1.remove_ratio(transfer_ratio)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
/obj/machinery/atmospherics/binary/volume_pump/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency)
/obj/machinery/atmospherics/binary/volume_pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "APV",
"power" = on,
"transfer_rate" = transfer_rate,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal)
return 1
/obj/machinery/atmospherics/binary/volume_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if(signal.data["power"])
on = text2num(signal.data["power"])
if(signal.data["power_toggle"])
on = !on
if(signal.data["set_transfer_rate"])
transfer_rate = between(
0,
text2num(signal.data["set_transfer_rate"]),
air1.volume
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/volume_pump/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/volume_pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 310, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/volume_pump/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["rate"] = round(transfer_rate)
data["max_rate"] = round(MAX_TRANSFER_RATE)
return data
/obj/machinery/atmospherics/binary/volume_pump/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["rate"])
var/rate = href_list["rate"]
if(rate == "max")
rate = MAX_TRANSFER_RATE
. = TRUE
else if(rate == "input")
rate = input("New transfer rate (0-[MAX_TRANSFER_RATE] L/s):", name, transfer_rate) as num|null
if(!isnull(rate))
. = TRUE
else if(text2num(rate) != null)
rate = text2num(rate)
. = TRUE
if(.)
transfer_rate = Clamp(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/volume_pump/power_change()
var/old_stat = stat
..()
if(old_stat != stat)
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/attackby(obj/item/W, mob/user, params)
if(istype(W, /obj/item/pen))
var/t = copytext(stripped_input(user, "Enter the name for the volume pump.", "Rename", name), 1, MAX_NAME_LEN)
if(!t)
return
if(!in_range(src, usr) && loc != usr)
return
name = t
return
else if(!istype(W, /obj/item/wrench))
return ..()
if(!(stat & NOPOWER) && on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()