Fixes #2926
Now master alarm in area polls all other alarms and sets area alert level to highest out of them. So no more green alarms opening lockdowns until they turn red too.
This commit is contained in:
@@ -135,30 +135,7 @@
|
||||
if(!istype(location)) return//returns if loc is not simulated
|
||||
|
||||
var/datum/gas_mixture/environment = location.return_air()
|
||||
var/partial_pressure = R_IDEAL_GAS_EQUATION*environment.temperature/environment.volume
|
||||
|
||||
var/list/current_settings = TLV["pressure"]
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
var/pressure_dangerlevel = get_danger_level(environment_pressure, current_settings)
|
||||
|
||||
current_settings = TLV["oxygen"]
|
||||
var/oxygen_dangerlevel = get_danger_level(environment.oxygen*partial_pressure, current_settings)
|
||||
|
||||
current_settings = TLV["carbon dioxide"]
|
||||
var/co2_dangerlevel = get_danger_level(environment.carbon_dioxide*partial_pressure, current_settings)
|
||||
|
||||
current_settings = TLV["plasma"]
|
||||
var/plasma_dangerlevel = get_danger_level(environment.toxins*partial_pressure, current_settings)
|
||||
|
||||
current_settings = TLV["other"]
|
||||
var/other_moles = 0.0
|
||||
for(var/datum/gas/G in environment.trace_gases)
|
||||
other_moles+=G.moles
|
||||
var/other_dangerlevel = get_danger_level(other_moles*partial_pressure, current_settings)
|
||||
|
||||
current_settings = TLV["temperature"]
|
||||
var/temperature_dangerlevel = get_danger_level(environment.temperature, current_settings)
|
||||
|
||||
var/temperature_dangerlevel = get_danger_level(environment.temperature, TLV["temperature"])
|
||||
//Handle temperature adjustment here.
|
||||
if(temperature_dangerlevel || regulating_temperature)
|
||||
//If it goes too far, we should adjust ourselves back before stopping.
|
||||
@@ -194,18 +171,14 @@
|
||||
"You hear a click as a faint electronic humming stops.")
|
||||
|
||||
|
||||
var/old_danger_level = danger_level
|
||||
danger_level = max(pressure_dangerlevel,
|
||||
oxygen_dangerlevel,
|
||||
co2_dangerlevel,
|
||||
plasma_dangerlevel,
|
||||
other_dangerlevel,
|
||||
temperature_dangerlevel)
|
||||
danger_level = overall_danger_level()
|
||||
log_debug("Processing [name] : level - [danger_level]")
|
||||
|
||||
if (old_danger_level != danger_level)
|
||||
apply_danger_level(danger_level)
|
||||
if (alarm_area.master_air_alarm == src)
|
||||
refresh_danger_level()
|
||||
update_icon()
|
||||
|
||||
if (mode==AALARM_MODE_CYCLE && environment_pressure<ONE_ATMOSPHERE*0.05)
|
||||
if (mode==AALARM_MODE_CYCLE && environment.return_pressure()<ONE_ATMOSPHERE*0.05)
|
||||
mode=AALARM_MODE_FILL
|
||||
apply_mode()
|
||||
|
||||
@@ -225,6 +198,33 @@
|
||||
updateDialog()
|
||||
return
|
||||
|
||||
proc/overall_danger_level()
|
||||
var/turf/simulated/location = loc
|
||||
if(!istype(location)) return//returns if loc is not simulated
|
||||
|
||||
var/datum/gas_mixture/environment = location.return_air()
|
||||
|
||||
var/partial_pressure = R_IDEAL_GAS_EQUATION*environment.temperature/environment.volume
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
var/other_moles = 0.0
|
||||
for(var/datum/gas/G in environment.trace_gases)
|
||||
other_moles+=G.moles
|
||||
|
||||
var/pressure_dangerlevel = get_danger_level(environment_pressure, TLV["pressure"])
|
||||
var/oxygen_dangerlevel = get_danger_level(environment.oxygen*partial_pressure, TLV["oxygen"])
|
||||
var/co2_dangerlevel = get_danger_level(environment.carbon_dioxide*partial_pressure, TLV["carbon dioxide"])
|
||||
var/plasma_dangerlevel = get_danger_level(environment.toxins*partial_pressure, TLV["plasma"])
|
||||
var/temperature_dangerlevel = get_danger_level(environment.temperature, TLV["temperature"])
|
||||
var/other_dangerlevel = get_danger_level(other_moles*partial_pressure, TLV["other"])
|
||||
|
||||
return max(
|
||||
pressure_dangerlevel,
|
||||
oxygen_dangerlevel,
|
||||
co2_dangerlevel,
|
||||
plasma_dangerlevel,
|
||||
other_dangerlevel,
|
||||
temperature_dangerlevel
|
||||
)
|
||||
|
||||
proc/master_is_operating()
|
||||
return alarm_area.master_air_alarm && !(alarm_area.master_air_alarm.stat & (NOPOWER|BROKEN))
|
||||
@@ -383,6 +383,15 @@
|
||||
|
||||
update_icon()
|
||||
|
||||
proc/refresh_danger_level()
|
||||
var/level = 0
|
||||
for (var/area/A in alarm_area.related)
|
||||
for (var/obj/machinery/alarm/AA in A)
|
||||
if ( !(AA.stat & (NOPOWER|BROKEN)) && !AA.shorted)
|
||||
if (AA.danger_level > level)
|
||||
level = AA.danger_level
|
||||
apply_danger_level(level)
|
||||
|
||||
proc/air_doors_close(manual)
|
||||
var/area/A = get_area(src)
|
||||
if(!A.master.air_doors_activated)
|
||||
|
||||