-Proper fix for the scrubber/vent runtimes.

I made the vents and scrubbers update the area scrubber/vent info themselves, meaning that an air alarm isn't required to initialize the area/vent info and to stop it from being null.

This will add more flexibility in the future.

git-svn-id: http://tgstation13.googlecode.com/svn/trunk@5331 316c924e-a436-60f5-8080-3fe189b3f50e
This commit is contained in:
giacomand@gmail.com
2012-12-15 18:59:47 +00:00
parent f00b0d72d8
commit 7caff5dd42
3 changed files with 47 additions and 78 deletions
+20 -13
View File
@@ -162,6 +162,12 @@
"sigtype" = "status"
)
if(!initial_loc.air_vent_names[id_tag])
var/new_name = "[initial_loc.name] Vent Pump #[initial_loc.air_vent_names.len+1]"
initial_loc.air_vent_names[id_tag] = new_name
src.name = new_name
initial_loc.air_vent_info[id_tag] = signal.data
radio_connection.post_signal(src, signal, radio_filter_out)
return 1
@@ -183,62 +189,62 @@
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
return 0
if("purge" in signal.data)
if(signal.data["purge"] != null)
pressure_checks &= ~1
pump_direction = 0
if("stabalize" in signal.data)
if(signal.data["stabalize"] != null)
pressure_checks |= 1
pump_direction = 1
if("power" in signal.data)
if(signal.data["power"] != null)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
if(signal.data["power_toggle"] != null)
on = !on
if("checks" in signal.data)
if(signal.data["checks"] != null)
pressure_checks = text2num(signal.data["checks"])
if("checks_toggle" in signal.data)
if(signal.data["checks_toggle"] != null)
pressure_checks = (pressure_checks?0:3)
if("direction" in signal.data)
if(signal.data["direction"] != null)
pump_direction = text2num(signal.data["direction"])
if("set_internal_pressure" in signal.data)
if(signal.data["set_internal_pressure"] != null)
internal_pressure_bound = between(
0,
text2num(signal.data["set_internal_pressure"]),
ONE_ATMOSPHERE*50
)
if("set_external_pressure" in signal.data)
if(signal.data["set_external_pressure"] != null)
external_pressure_bound = between(
0,
text2num(signal.data["set_external_pressure"]),
ONE_ATMOSPHERE*50
)
if("adjust_internal_pressure" in signal.data)
if(signal.data["adjust_internal_pressure"] != null)
internal_pressure_bound = between(
0,
internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]),
ONE_ATMOSPHERE*50
)
if("adjust_external_pressure" in signal.data)
if(signal.data["adjust_external_pressure"] != null)
external_pressure_bound = between(
0,
external_pressure_bound + text2num(signal.data["adjust_external_pressure"]),
ONE_ATMOSPHERE*50
)
if("init" in signal.data)
if(signal.data["init"] != null)
name = signal.data["init"]
return
if("status" in signal.data)
if(signal.data["status"] != null)
spawn(2)
broadcast_status()
return //do not update_icon
@@ -326,5 +332,6 @@
/obj/machinery/atmospherics/unary/vent_pump/Del()
if(initial_loc)
initial_loc.air_vent_info -= id_tag
initial_loc.air_vent_names -= id_tag
..()
return
@@ -73,6 +73,11 @@
"filter_n2o" = scrub_N2O,
"sigtype" = "status"
)
if(!initial_loc.air_scrub_names[id_tag])
var/new_name = "[initial_loc.name] Air Scrubber #[initial_loc.air_scrub_names.len+1]"
initial_loc.air_scrub_names[id_tag] = new_name
src.name = new_name
initial_loc.air_scrub_info[id_tag] = signal.data
radio_connection.post_signal(src, signal, radio_filter_out)
return 1
@@ -167,13 +172,13 @@
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
return 0
if("power" in signal.data)
if(signal.data["power"] != null)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
if(signal.data["power_toggle"] != null)
on = !on
if("panic_siphon" in signal.data) //must be before if("scrubbing" thing
panic = text2num(signal.data["panic_siphon"])
if(signal.data["panic_siphon"]) //must be before if("scrubbing" thing
panic = text2num(signal.data["panic_siphon"] != null)
if(panic)
on = 1
scrubbing = 0
@@ -181,7 +186,7 @@
else
scrubbing = 1
volume_rate = initial(volume_rate)
if("toggle_panic_siphon" in signal.data)
if(signal.data["toggle_panic_siphon"] != null)
panic = !panic
if(panic)
on = 1
@@ -191,31 +196,31 @@
scrubbing = 1
volume_rate = initial(volume_rate)
if("scrubbing" in signal.data)
if(signal.data["scrubbing"] != null)
scrubbing = text2num(signal.data["scrubbing"])
if("toggle_scrubbing" in signal.data)
if(signal.data["toggle_scrubbing"])
scrubbing = !scrubbing
if("co2_scrub" in signal.data)
if(signal.data["co2_scrub"] != null)
scrub_CO2 = text2num(signal.data["co2_scrub"])
if("toggle_co2_scrub" in signal.data)
if(signal.data["toggle_co2_scrub"])
scrub_CO2 = !scrub_CO2
if("tox_scrub" in signal.data)
if(signal.data["tox_scrub"] != null)
scrub_Toxins = text2num(signal.data["tox_scrub"])
if("toggle_tox_scrub" in signal.data)
if(signal.data["toggle_tox_scrub"])
scrub_Toxins = !scrub_Toxins
if("n2o_scrub" in signal.data)
if(signal.data["n2o_scrub"] != null)
scrub_N2O = text2num(signal.data["n2o_scrub"])
if("toggle_n2o_scrub" in signal.data)
if(signal.data["toggle_n2o_scrub"])
scrub_N2O = !scrub_N2O
if("init" in signal.data)
if(signal.data["init"] != null)
name = signal.data["init"]
return
if("status" in signal.data)
if(signal.data["status"] != null)
spawn(2)
broadcast_status()
return //do not update_icon
@@ -260,6 +265,8 @@
del(src)
/obj/machinery/atmospherics/unary/vent_scrubber/Del()
initial_loc.air_scrub_info -= id_tag
if(initial_loc)
initial_loc.air_scrub_info -= id_tag
initial_loc.air_scrub_names -= id_tag
..()
return
+4 -49
View File
@@ -138,10 +138,10 @@
//all air alarms in area are connected via magic
/area
var/obj/machinery/alarm/master_air_alarm
var/list/air_vent_names
var/list/air_scrub_names
var/list/air_vent_info
var/list/air_scrub_info
var/list/air_vent_names = list()
var/list/air_scrub_names = list()
var/list/air_vent_info = list()
var/list/air_scrub_info = list()
/obj/machinery/alarm/New(nloc, ndir, nbuild)
..()
@@ -179,11 +179,6 @@
for (var/obj/machinery/alarm/AA in A)
if (!(AA.stat & (NOPOWER|BROKEN)))
alarm_area.master_air_alarm = AA
if (!alarm_area.air_vent_names)
alarm_area.air_vent_names = new
alarm_area.air_scrub_names = new
alarm_area.air_vent_info = new
alarm_area.air_scrub_info = new
return 1
return 0
@@ -379,46 +374,6 @@
else
return 0
/obj/machinery/alarm/receive_signal(datum/signal/signal)
if(stat & (NOPOWER|BROKEN))
return
if (alarm_area.master_air_alarm != src)
if (master_is_operating())
return
elect_master()
if (alarm_area.master_air_alarm != src)
return
if(!signal || signal.encryption)
return
var/id_tag = signal.data["tag"]
if (!id_tag)
return
if (signal.data["area"] != area_uid)
return
if (signal.data["sigtype"] != "status")
return
var/dev_type = signal.data["device"]
if(!(id_tag in alarm_area.air_scrub_names) && !(id_tag in alarm_area.air_vent_names))
register_env_machine(id_tag, dev_type)
if(dev_type == "AScr")
alarm_area.air_scrub_info[id_tag] = signal.data
else if(dev_type == "AVP")
alarm_area.air_vent_info[id_tag] = signal.data
/obj/machinery/alarm/proc/register_env_machine(var/m_id, var/device_type)
var/new_name
if (device_type=="AVP")
new_name = "[alarm_area.name] Vent Pump #[alarm_area.air_vent_names.len+1]"
alarm_area.air_vent_names[m_id] = new_name
else if (device_type=="AScr")
new_name = "[alarm_area.name] Air Scrubber #[alarm_area.air_scrub_names.len+1]"
alarm_area.air_scrub_names[m_id] = new_name
else
return
spawn (10)
send_signal(m_id, list("init" = new_name) )
/obj/machinery/alarm/proc/refresh_all()
for(var/id_tag in alarm_area.air_vent_names)
var/list/I = alarm_area.air_vent_info[id_tag]