-Proper fix for the scrubber/vent runtimes.

I made the vents and scrubbers update the area scrubber/vent info themselves, meaning that an air alarm isn't required to initialize the area/vent info and to stop it from being null.

This will add more flexibility in the future.

git-svn-id: http://tgstation13.googlecode.com/svn/trunk@5331 316c924e-a436-60f5-8080-3fe189b3f50e
This commit is contained in:
giacomand@gmail.com
2012-12-15 18:59:47 +00:00
parent f00b0d72d8
commit 7caff5dd42
3 changed files with 47 additions and 78 deletions
+4 -49
View File
@@ -138,10 +138,10 @@
//all air alarms in area are connected via magic
/area
var/obj/machinery/alarm/master_air_alarm
var/list/air_vent_names
var/list/air_scrub_names
var/list/air_vent_info
var/list/air_scrub_info
var/list/air_vent_names = list()
var/list/air_scrub_names = list()
var/list/air_vent_info = list()
var/list/air_scrub_info = list()
/obj/machinery/alarm/New(nloc, ndir, nbuild)
..()
@@ -179,11 +179,6 @@
for (var/obj/machinery/alarm/AA in A)
if (!(AA.stat & (NOPOWER|BROKEN)))
alarm_area.master_air_alarm = AA
if (!alarm_area.air_vent_names)
alarm_area.air_vent_names = new
alarm_area.air_scrub_names = new
alarm_area.air_vent_info = new
alarm_area.air_scrub_info = new
return 1
return 0
@@ -379,46 +374,6 @@
else
return 0
/obj/machinery/alarm/receive_signal(datum/signal/signal)
if(stat & (NOPOWER|BROKEN))
return
if (alarm_area.master_air_alarm != src)
if (master_is_operating())
return
elect_master()
if (alarm_area.master_air_alarm != src)
return
if(!signal || signal.encryption)
return
var/id_tag = signal.data["tag"]
if (!id_tag)
return
if (signal.data["area"] != area_uid)
return
if (signal.data["sigtype"] != "status")
return
var/dev_type = signal.data["device"]
if(!(id_tag in alarm_area.air_scrub_names) && !(id_tag in alarm_area.air_vent_names))
register_env_machine(id_tag, dev_type)
if(dev_type == "AScr")
alarm_area.air_scrub_info[id_tag] = signal.data
else if(dev_type == "AVP")
alarm_area.air_vent_info[id_tag] = signal.data
/obj/machinery/alarm/proc/register_env_machine(var/m_id, var/device_type)
var/new_name
if (device_type=="AVP")
new_name = "[alarm_area.name] Vent Pump #[alarm_area.air_vent_names.len+1]"
alarm_area.air_vent_names[m_id] = new_name
else if (device_type=="AScr")
new_name = "[alarm_area.name] Air Scrubber #[alarm_area.air_scrub_names.len+1]"
alarm_area.air_scrub_names[m_id] = new_name
else
return
spawn (10)
send_signal(m_id, list("init" = new_name) )
/obj/machinery/alarm/proc/refresh_all()
for(var/id_tag in alarm_area.air_vent_names)
var/list/I = alarm_area.air_vent_info[id_tag]