Merge remote-tracking branch 'upstream/master' into tgui-filter

This commit is contained in:
SteelSlayer
2020-09-15 20:25:24 -05:00
195 changed files with 11814 additions and 8154 deletions
@@ -137,51 +137,56 @@
return
add_fingerprint(user)
ui_interact(user)
tgui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/attack_ghost(mob/user)
ui_interact(user)
tgui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = GLOB.default_state)
/obj/machinery/atmospherics/binary/passive_gate/tgui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, datum/tgui/master_ui = null, datum/tgui_state/state = GLOB.tgui_default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui = new(user, src, ui_key, "AtmosPump", name, 310, 110, master_ui, state)
ui.open()
/obj/machinery/atmospherics/binary/passive_gate/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
/obj/machinery/atmospherics/binary/passive_gate/tgui_data(mob/user)
var/list/data = list(
"on" = on,
"rate" = round(target_pressure),
"max_rate" = MAX_OUTPUT_PRESSURE,
"gas_unit" = "kPa",
"step" = 10 // This is for the TGUI <NumberInput> step. It's here since multiple pumps share the same UI, but need different values.
)
return data
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
/obj/machinery/atmospherics/binary/passive_gate/tgui_act(action, list/params)
if(..())
return 1
return
if(href_list["power"])
switch(action)
if("power")
toggle()
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
return TRUE
if("max_rate")
target_pressure = MAX_OUTPUT_PRESSURE
. = TRUE
if("min_rate")
target_pressure = 0
. = TRUE
if("custom_rate")
target_pressure = clamp(text2num(params["rate"]), 0 , MAX_OUTPUT_PRESSURE)
. = TRUE
if(.)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
/obj/machinery/atmospherics/binary/passive_gate/proc/toggle()
if(powered())
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
update_icon()
/obj/machinery/atmospherics/binary/passive_gate/attackby(obj/item/W, mob/user, params)
if(!istype(W, /obj/item/wrench))
@@ -192,51 +192,51 @@ Thus, the two variables affect pump operation are set in New():
return
add_fingerprint(user)
ui_interact(user)
tgui_interact(user)
/obj/machinery/atmospherics/binary/pump/attack_ghost(mob/user)
ui_interact(user)
tgui_interact(user)
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = GLOB.default_state)
/obj/machinery/atmospherics/binary/pump/tgui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, datum/tgui/master_ui = null, datum/tgui_state/state = GLOB.tgui_default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui = new(user, src, ui_key, "AtmosPump", name, 310, 110, master_ui, state)
ui.open()
/obj/machinery/atmospherics/binary/pump/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
/obj/machinery/atmospherics/binary/pump/tgui_data(mob/user)
var/list/data = list(
"on" = on,
"rate" = round(target_pressure),
"max_rate" = MAX_OUTPUT_PRESSURE,
"gas_unit" = "kPa",
"step" = 10 // This is for the TGUI <NumberInput> step. It's here since multiple pumps share the same UI, but need different values.
)
return data
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
/obj/machinery/atmospherics/binary/pump/tgui_act(action, list/params)
if(..())
return 1
return
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
switch(action)
if("power")
toggle()
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
return TRUE
update_icon()
SSnanoui.update_uis(src)
if("max_rate")
target_pressure = MAX_OUTPUT_PRESSURE
. = TRUE
if("min_rate")
target_pressure = 0
. = TRUE
if("custom_rate")
target_pressure = clamp(text2num(params["rate"]), 0 , MAX_OUTPUT_PRESSURE)
. = TRUE
if(.)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
/obj/machinery/atmospherics/binary/pump/power_change()
var/old_stat = stat
@@ -188,51 +188,51 @@ Thus, the two variables affect pump operation are set in New():
return
add_fingerprint(user)
ui_interact(user)
tgui_interact(user)
/obj/machinery/atmospherics/binary/volume_pump/attack_ghost(mob/user)
ui_interact(user)
tgui_interact(user)
/obj/machinery/atmospherics/binary/volume_pump/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = GLOB.default_state)
/obj/machinery/atmospherics/binary/volume_pump/tgui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, datum/tgui/master_ui = null, datum/tgui_state/state = GLOB.tgui_default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 310, 115, state = state)
ui = new(user, src, ui_key, "AtmosPump", name, 310, 110, master_ui, state)
ui.open()
/obj/machinery/atmospherics/binary/volume_pump/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["rate"] = round(transfer_rate)
data["max_rate"] = round(MAX_TRANSFER_RATE)
/obj/machinery/atmospherics/binary/volume_pump/tgui_data(mob/user)
var/list/data = list(
"on" = on,
"rate" = round(transfer_rate),
"max_rate" = round(MAX_TRANSFER_RATE),
"gas_unit" = "L/s",
"step" = 1 // This is for the TGUI <NumberInput> step. It's here since multiple pumps share the same UI, but need different values.
)
return data
/obj/machinery/atmospherics/binary/volume_pump/Topic(href,href_list)
/obj/machinery/atmospherics/binary/volume_pump/tgui_act(action, list/params)
if(..())
return 1
return
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["rate"])
var/rate = href_list["rate"]
if(rate == "max")
rate = MAX_TRANSFER_RATE
. = TRUE
else if(rate == "input")
rate = input("New transfer rate (0-[MAX_TRANSFER_RATE] L/s):", name, transfer_rate) as num|null
if(!isnull(rate))
. = TRUE
else if(text2num(rate) != null)
rate = text2num(rate)
. = TRUE
if(.)
transfer_rate = clamp(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", "atmos")
switch(action)
if("power")
toggle()
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
return TRUE
update_icon()
SSnanoui.update_uis(src)
if("max_rate")
transfer_rate = MAX_TRANSFER_RATE
. = TRUE
if("min_rate")
transfer_rate = 0
. = TRUE
if("custom_rate")
transfer_rate = clamp(text2num(params["rate"]), 0 , MAX_TRANSFER_RATE)
. = TRUE
if(.)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", "atmos")
/obj/machinery/atmospherics/binary/volume_pump/power_change()
var/old_stat = stat