Continued work in progress on a major revision of the NanoUI templating system.

Conflicts:
	code/ATMOSPHERICS/components/omni_devices/filter.dm
	code/ATMOSPHERICS/components/omni_devices/mixer.dm
	code/game/dna/dna_modifier.dm
	code/game/machinery/cryo.dm
	code/game/machinery/kitchen/smartfridge.dm
	code/modules/nano/nanoexternal.dm
	code/modules/nano/nanomanager.dm
	code/modules/nano/nanoui.dm
	code/modules/power/apc.dm
	code/modules/power/smes.dm
	code/modules/reagents/Chemistry-Machinery.dm
	nano/css/shared.css
	nano/js/nano_update.js
	nano/templates/escape_pod_console.tmpl
This commit is contained in:
Mark Aherne
2014-07-15 07:22:15 -04:00
committed by ZomgPonies
parent 4b4f85c22e
commit 9b45dbabfb
73 changed files with 2231 additions and 1268 deletions
@@ -0,0 +1,282 @@
//--------------------------------------------
// Gas filter - omni variant
//--------------------------------------------
/obj/machinery/atmospherics/omni/filter
name = "omni gas filter"
icon_state = "map_filter"
var/list/filters = new()
var/datum/omni_port/input
var/datum/omni_port/output
/obj/machinery/atmospherics/omni/filter/Del()
input = null
output = null
filters.Cut()
..()
/obj/machinery/atmospherics/omni/filter/sort_ports()
for(var/datum/omni_port/P in ports)
if(P.update)
if(output == P)
output = null
if(input == P)
input = null
if(filters.Find(P))
filters -= P
P.air.volume = 200
switch(P.mode)
if(ATM_INPUT)
input = P
if(ATM_OUTPUT)
output = P
if(ATM_O2 to ATM_N2O)
filters += P
/obj/machinery/atmospherics/omni/filter/error_check()
if(!input || !output || !filters)
return 1
if(filters.len < 1 || filters.len > 2) //requires 1 or 2 filters ~otherwise why are you using a filter?
return 1
return 0
/obj/machinery/atmospherics/omni/filter/process()
..()
if(!on)
return 0
if(!input || !output)
return
var/datum/gas_mixture/output_air = output.air //BYOND doesn't like referencing "output.air.return_pressure()" so we need to make a direct reference
var/datum/gas_mixture/input_air = input.air // it's completely happy with them if they're in a loop though i.e. "P.air.return_pressure()"... *shrug*
var/output_pressure = output_air.return_pressure()
if(output_pressure >= target_pressure)
return
for(var/datum/omni_port/P in filters)
if(P.air.return_pressure() >= target_pressure)
return
var/pressure_delta = target_pressure - output_pressure
if(input_air.return_temperature() > 0)
input.transfer_moles = pressure_delta * output_air.volume / (input_air.return_temperature() * R_IDEAL_GAS_EQUATION)
if(input.transfer_moles > 0)
var/datum/gas_mixture/removed = input_air.remove(input.transfer_moles)
if(!removed)
return
for(var/datum/omni_port/P in filters)
var/datum/gas_mixture/filtered_out = new
filtered_out.temperature = removed.return_temperature()
switch(P.mode)
if(ATM_O2)
filtered_out.oxygen = removed.oxygen
removed.oxygen = 0
if(ATM_N2)
filtered_out.nitrogen = removed.nitrogen
removed.nitrogen = 0
if(ATM_CO2)
filtered_out.carbon_dioxide = removed.carbon_dioxide
removed.carbon_dioxide = 0
if(ATM_P)
filtered_out.phoron = removed.phoron
removed.phoron = 0
if(ATM_N2O)
if(removed.trace_gases.len>0)
for(var/datum/gas/sleeping_agent/trace_gas in removed.trace_gases)
if(istype(trace_gas))
removed.trace_gases -= trace_gas
filtered_out.trace_gases += trace_gas
else
filtered_out = null
P.air.merge(filtered_out)
if(P.network)
P.network.update = 1
output_air.merge(removed)
if(output.network)
output.network.update = 1
input.transfer_moles = 0
if(input.network)
input.network.update = 1
return
/obj/machinery/atmospherics/omni/filter/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1)
usr.set_machine(src)
var/list/data = new()
data = build_uidata()
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
if (!ui)
ui = new(user, src, ui_key, "omni_filter.tmpl", "Omni Filter Control", 330, 330)
ui.set_initial_data(data)
ui.open()
/obj/machinery/atmospherics/omni/filter/proc/build_uidata()
var/list/data = new()
data["power"] = on
data["config"] = configuring
var/portData[0]
for(var/datum/omni_port/P in ports)
if(!configuring && P.mode == 0)
continue
var/input = 0
var/output = 0
var/filter = 1
var/f_type = null
switch(P.mode)
if(ATM_INPUT)
input = 1
filter = 0
if(ATM_OUTPUT)
output = 1
filter = 0
if(ATM_O2 to ATM_N2O)
f_type = mode_send_switch(P.mode)
portData[++portData.len] = list("dir" = dir_name(P.dir, capitalize = 1), \
"input" = input, \
"output" = output, \
"filter" = filter, \
"f_type" = f_type)
if(portData.len)
data["ports"] = portData
if(output)
data["pressure"] = target_pressure
return data
/obj/machinery/atmospherics/omni/filter/proc/mode_send_switch(var/mode = ATM_NONE)
switch(mode)
if(ATM_O2)
return "Oxygen"
if(ATM_N2)
return "Nitrogen"
if(ATM_CO2)
return "Carbon Dioxide"
if(ATM_P)
return "Phoron" //*cough* Plasma *cough*
if(ATM_N2O)
return "Nitrous Oxide"
else
return null
/obj/machinery/atmospherics/omni/filter/Topic(href, href_list)
if(..()) return
switch(href_list["command"])
if("power")
if(!configuring)
on = !on
else
on = 0
if("configure")
configuring = !configuring
if(configuring)
on = 0
//only allows config changes when in configuring mode ~otherwise you'll get weird pressure stuff going on
if(configuring && !on)
switch(href_list["command"])
if("set_pressure")
var/new_pressure = input(usr,"Enter new output pressure (0-4500kPa)","Pressure control",target_pressure) as num
target_pressure = between(0, new_pressure, 4500)
if("switch_mode")
switch_mode(dir_flag(href_list["dir"]), mode_return_switch(href_list["mode"]))
if("switch_filter")
var/new_filter = input(usr,"Select filter mode:","Change filter",href_list["mode"]) in list("None", "Oxygen", "Nitrogen", "Carbon Dioxide", "Phoron", "Nitrous Oxide")
switch_filter(dir_flag(href_list["dir"]), mode_return_switch(new_filter))
update_icon()
nanomanager.update_uis(src)
return
/obj/machinery/atmospherics/omni/filter/proc/mode_return_switch(var/mode)
switch(mode)
if("Oxygen")
return ATM_O2
if("Nitrogen")
return ATM_N2
if("Carbon Dioxide")
return ATM_CO2
if("Phoron")
return ATM_P
if("Nitrous Oxide")
return ATM_N2O
if("in")
return ATM_INPUT
if("out")
return ATM_OUTPUT
if("None")
return ATM_NONE
else
return null
/obj/machinery/atmospherics/omni/filter/proc/switch_filter(var/dir, var/mode)
//check they aren't trying to disable the input or output ~this can only happen if they hack the cached tmpl file
for(var/datum/omni_port/P in ports)
if(P.dir == dir)
if(P.mode == ATM_INPUT || P.mode == ATM_OUTPUT)
return
switch_mode(dir, mode)
/obj/machinery/atmospherics/omni/filter/proc/switch_mode(var/port, var/mode)
if(mode == null || !port)
return
var/datum/omni_port/target_port = null
var/list/other_ports = new()
for(var/datum/omni_port/P in ports)
if(P.dir == port)
target_port = P
else
other_ports += P
var/previous_mode = null
if(target_port)
previous_mode = target_port.mode
target_port.mode = mode
if(target_port.mode != previous_mode)
handle_port_change(target_port)
else
return
else
return
for(var/datum/omni_port/P in other_ports)
if(P.mode == mode)
var/old_mode = P.mode
P.mode = previous_mode
if(P.mode != old_mode)
handle_port_change(P)
update_ports()
/obj/machinery/atmospherics/omni/filter/proc/handle_port_change(var/datum/omni_port/P)
switch(P.mode)
if(ATM_NONE)
initialize_directions &= ~P.dir
P.disconnect()
else
initialize_directions |= P.dir
P.connect()
P.update = 1
@@ -0,0 +1,301 @@
//--------------------------------------------
// Gas mixer - omni variant
//--------------------------------------------
/obj/machinery/atmospherics/omni/mixer
name = "omni gas mixer"
icon_state = "map_mixer"
var/list/inputs = new()
var/datum/omni_port/output
//setup tags for initial concentration values (must be decimal)
var/tag_north_con
var/tag_south_con
var/tag_east_con
var/tag_west_con
/obj/machinery/atmospherics/omni/mixer/New()
..()
if(mapper_set())
var/con = 0
for(var/datum/omni_port/P in ports)
switch(P.dir)
if(NORTH)
if(tag_north_con && tag_north == 1)
P.concentration = tag_north_con
con += max(0, tag_north_con)
if(SOUTH)
if(tag_south_con && tag_south == 1)
P.concentration = tag_south_con
con += max(0, tag_south_con)
if(EAST)
if(tag_east_con && tag_east == 1)
P.concentration = tag_east_con
con += max(0, tag_east_con)
if(WEST)
if(tag_west_con && tag_west == 1)
P.concentration = tag_west_con
con += max(0, tag_west_con)
//mappers who are bad at maths will be punished (total concentration must be 100%)
if(con != 1)
tag_north_con = null
tag_south_con = null
tag_east_con = null
tag_west_con = null
/obj/machinery/atmospherics/omni/mixer/Del()
inputs.Cut()
output = null
..()
/obj/machinery/atmospherics/omni/mixer/sort_ports()
for(var/datum/omni_port/P in ports)
if(P.update)
if(output == P)
output = null
if(inputs.Find(P))
inputs -= P
P.air.volume = 200
switch(P.mode)
if(ATM_INPUT)
inputs += P
if(ATM_OUTPUT)
output = P
if(!mapper_set())
for(var/datum/omni_port/P in inputs)
P.concentration = 1 / max(1, inputs.len)
if(output)
output.air.volume *= 0.75 * inputs.len
output.concentration = 1
/obj/machinery/atmospherics/omni/mixer/proc/mapper_set()
return (tag_north_con || tag_south_con || tag_east_con || tag_west_con)
/obj/machinery/atmospherics/omni/mixer/error_check()
if(!output || !inputs)
return 1
if(inputs.len < 2 || inputs.len > 3) //requires 2 or 3 inputs ~otherwise why are you using a mixer?
return 1
return 0
/obj/machinery/atmospherics/omni/mixer/process()
..()
if(!on)
return 0
var/datum/gas_mixture/output_air = output.air
var/output_pressure = output_air.return_pressure()
if(output_pressure >= target_pressure * 0.999)
//No need to mix if target is already full! - 0.1% margin of error so we minimize processing minor gas volumes
return 1
//Calculate necessary moles to transfer using PV=nRT
var/pressure_delta = target_pressure - output_pressure
for(var/datum/omni_port/P in inputs)
if(P.air.return_temperature() > 0)
P.transfer_moles = (P.concentration * pressure_delta) * output_air.return_volume() / (P.air.return_temperature() * R_IDEAL_GAS_EQUATION)
var/ratio_check = null
for(var/datum/omni_port/P in inputs)
if(!P.transfer_moles)
return
if(P.air.total_moles() < P.transfer_moles)
ratio_check = 1
continue
if(ratio_check)
var/list/ratio_list = new()
for(var/datum/omni_port/P in inputs)
ratio_list.Add(P.air.total_moles() / P.transfer_moles)
var/ratio = min(ratio_list)
for(var/datum/omni_port/P in inputs)
P.transfer_moles *= ratio
for(var/datum/omni_port/P in inputs)
if(P.transfer_moles > 0)
output_air.merge(P.air.remove(P.transfer_moles))
if(P.network)
P.network.update = 1
P.transfer_moles = 0
if(output.network)
output.network.update = 1
return 1
/obj/machinery/atmospherics/omni/mixer/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1)
usr.set_machine(src)
var/list/data = new()
data = build_uidata()
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
if (!ui)
ui = new(user, src, ui_key, "omni_mixer.tmpl", "Omni Mixer Control", 360, 330)
ui.set_initial_data(data)
ui.open()
/obj/machinery/atmospherics/omni/mixer/proc/build_uidata()
var/list/data = new()
data["power"] = on
data["config"] = configuring
var/portData[0]
for(var/datum/omni_port/P in ports)
if(!configuring && P.mode == 0)
continue
var/input = 0
var/output = 0
switch(P.mode)
if(ATM_INPUT)
input = 1
if(ATM_OUTPUT)
output = 1
portData[++portData.len] = list("dir" = dir_name(P.dir, capitalize = 1), \
"concentration" = P.concentration, \
"input" = input, \
"output" = output, \
"con_lock" = P.con_lock)
if(portData.len)
data["ports"] = portData
if(output)
data["pressure"] = target_pressure
return data
/obj/machinery/atmospherics/omni/mixer/Topic(href, href_list)
if(..()) return
switch(href_list["command"])
if("power")
if(!configuring)
on = !on
else
on = 0
if("configure")
configuring = !configuring
if(configuring)
on = 0
//only allows config changes when in configuring mode ~otherwise you'll get weird pressure stuff going on
if(configuring && !on)
switch(href_list["command"])
if("set_pressure")
var/new_pressure = input(usr,"Enter new output pressure (0-4500kPa)","Pressure control",target_pressure) as num
target_pressure = between(0, new_pressure, 4500)
if("switch_mode")
switch_mode(dir_flag(href_list["dir"]), href_list["mode"])
if("switch_con")
change_concentration(dir_flag(href_list["dir"]))
if("switch_conlock")
con_lock(dir_flag(href_list["dir"]))
update_icon()
nanomanager.update_uis(src)
return
/obj/machinery/atmospherics/omni/mixer/proc/switch_mode(var/port = NORTH, var/mode = ATM_NONE)
if(mode != ATM_INPUT && mode != ATM_OUTPUT)
switch(mode)
if("in")
mode = ATM_INPUT
if("out")
mode = ATM_OUTPUT
else
mode = ATM_NONE
for(var/datum/omni_port/P in ports)
var/old_mode = P.mode
if(P.dir == port)
switch(mode)
if(ATM_INPUT)
if(P.mode == ATM_OUTPUT)
return
P.mode = mode
if(ATM_OUTPUT)
P.mode = mode
if(ATM_NONE)
if(P.mode == ATM_OUTPUT)
return
if(P.mode == ATM_INPUT && inputs.len > 2)
P.mode = mode
else if(P.mode == ATM_OUTPUT && mode == ATM_OUTPUT)
P.mode = ATM_INPUT
if(P.mode != old_mode)
switch(P.mode)
if(ATM_NONE)
initialize_directions &= ~P.dir
P.disconnect()
else
initialize_directions |= P.dir
P.connect()
P.update = 1
update_ports()
/obj/machinery/atmospherics/omni/mixer/proc/change_concentration(var/port = NORTH)
tag_north_con = null
tag_south_con = null
tag_east_con = null
tag_west_con = null
var/old_con = 0
var/non_locked = 0
var/remain_con = 1
for(var/datum/omni_port/P in inputs)
if(P.dir == port)
old_con = P.concentration
else if(!P.con_lock)
non_locked++
else
remain_con -= P.concentration
//return if no adjustable ports
if(non_locked < 1)
return
var/new_con = (input(usr,"Enter a new concentration (0-[round(remain_con * 100, 0.5)])%","Concentration control", min(remain_con, old_con)*100) as num) / 100
//cap it between 0 and the max remaining concentration
new_con = between(0, new_con, remain_con)
//new_con = min(remain_con, new_con)
//clamp remaining concentration so we don't go into negatives
remain_con = max(0, remain_con - new_con)
//distribute remaining concentration between unlocked ports evenly
remain_con /= max(1, non_locked)
for(var/datum/omni_port/P in inputs)
if(P.dir == port)
P.concentration = new_con
else if(!P.con_lock)
P.concentration = remain_con
/obj/machinery/atmospherics/omni/mixer/proc/con_lock(var/port = NORTH)
for(var/datum/omni_port/P in inputs)
if(P.dir == port)
P.con_lock = !P.con_lock