diff --git a/code/ATMOSPHERICS/components/unary/vent_pump.dm b/code/ATMOSPHERICS/components/unary/vent_pump.dm
index 2f7253f045c..a8a0b13b9dc 100644
--- a/code/ATMOSPHERICS/components/unary/vent_pump.dm
+++ b/code/ATMOSPHERICS/components/unary/vent_pump.dm
@@ -24,6 +24,12 @@
var/welded = 0 // Added for aliens -- TLE
+ var/frequency = 1439
+ var/datum/radio_frequency/radio_connection
+
+ var/radio_filter_out
+ var/radio_filter_in
+
New()
var/area/A = get_area(loc)
if (A.master)
@@ -37,22 +43,14 @@
broadcast_status()
..()
- Del()
- var/area/alarm_area = get_area(src)
- if(alarm_area && "\"[id_tag]\"" in alarm_area.master.air_vents)
- alarm_area.master.air_vents.Remove("\"[id_tag]\"")
- ..()
-
high_volume
name = "Large Air Vent"
+ power_channel = EQUIP
New()
..()
air_contents.volume = 1000
- initialize()
- spawn(20)
- broadcast_status()
update_icon()
if(welded)
@@ -70,7 +68,7 @@
process()
..()
- broadcast_status()
+// broadcast_status()
if(stat & (NOPOWER|BROKEN))
return
if (!node)
@@ -129,73 +127,99 @@
+ //Radio remote control
+
+ proc/set_frequency(new_frequency)
+ radio_controller.remove_object(src, frequency)
+ frequency = new_frequency
+ if(frequency)
+ radio_connection = radio_controller.add_object(src, frequency,radio_filter_in)
+
proc/broadcast_status()
- var/area/alarm_area = get_area(src)
- if(alarm_area.master.master_air_alarm)
- if(!id_tag)
- if(alarm_area.master.master_air_alarm)
- alarm_area.master.master_air_alarm.register_env_machine(src)
- world << "No ID, air alarm. New ID = [id_tag]"
- else
- world << "No ID, no air alarm."
- else if(!"\"[id_tag]\"" in alarm_area.air_vents)
- if(alarm_area.master.master_air_alarm)
- alarm_area.master.master_air_alarm.register_env_machine(src)
- world << "ID, air alarm. New ID = [id_tag]"
- else
- world << "ID = [id_tag], no air alarm."
- else if(stat & (NOPOWER|BROKEN))
- alarm_area.master.air_vents.Remove("\"[id_tag]\"")
- world << "Broken"
- else
- world << "Trying to register (No alarm)"
+ if(!radio_connection)
+ return 0
+
+ var/datum/signal/signal = new
+ signal.transmission_method = 1 //radio signal
+ signal.source = src
+
+ signal.data = list(
+ "area" = src.area_uid,
+ "tag" = src.id_tag,
+ "device" = "AVP",
+ "power" = on,
+ "direction" = pump_direction?("release"):("siphon"),
+ "checks" = pressure_checks,
+ "internal" = internal_pressure_bound,
+ "external" = external_pressure_bound,
+ "timestamp" = world.time,
+ "sigtype" = "status",
+ "setting" = pump_speed
+ )
+
+ radio_connection.post_signal(src, signal, radio_filter_out)
+
+ return 1
- proc/receive(var/list/signal)
+ initialize()
+ ..()
+
+ //some vents work his own spesial way
+ radio_filter_in = frequency==1439?(RADIO_FROM_AIRALARM):null
+ radio_filter_out = frequency==1439?(RADIO_TO_AIRALARM):null
+ if(frequency)
+ set_frequency(frequency)
+
+
+ receive_signal(datum/signal/signal)
if(stat & (NOPOWER|BROKEN))
return
+ //log_admin("DEBUG \[[world.timeofday]\]: /obj/machinery/atmospherics/unary/vent_pump/receive_signal([signal.debug_print()])")
+ if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
+ return 0
- if("purge" in signal)
+ if("purge" in signal.data)
pressure_checks &= ~1
pump_direction = 0
- if("stabalize" in signal)
+ if("stabalize" in signal.data)
pressure_checks |= 1
pump_direction = 1
- if("power" in signal)
- on = text2num(signal["power"])
+ if("power" in signal.data)
+ on = text2num(signal.data["power"])
- if("power_toggle" in signal)
+ if("power_toggle" in signal.data)
on = !on
- if("checks" in signal)
- pressure_checks = text2num(signal["checks"])
+ if("checks" in signal.data)
+ pressure_checks = text2num(signal.data["checks"])
- if("checks_toggle" in signal)
+ if("checks_toggle" in signal.data)
pressure_checks = (pressure_checks?0:3)
if("direction" in signal)
- pump_direction = text2num(signal["direction"])
+ pump_direction = text2num(signal.data["direction"])
- if("set_internal_pressure" in signal)
- internal_pressure_bound = between(0, text2num(signal["set_internal_pressure"]), ONE_ATMOSPHERE*50)
+ if("set_internal_pressure" in signal.data)
+ internal_pressure_bound = between(0, text2num(signal.data["set_internal_pressure"]), ONE_ATMOSPHERE*50)
- if("set_external_pressure" in signal)
- external_pressure_bound = between(0, text2num(signal["set_external_pressure"]), ONE_ATMOSPHERE*50)
+ if("set_external_pressure" in signal.data)
+ external_pressure_bound = between(0, text2num(signal.data["set_external_pressure"]), ONE_ATMOSPHERE*50)
- if("adjust_internal_pressure" in signal)
- internal_pressure_bound = between(0, text2num(signal["adjust_internal_pressure"]), ONE_ATMOSPHERE*50)
+ if("adjust_internal_pressure" in signal.data)
+ internal_pressure_bound = between(0, text2num(signal.data["adjust_internal_pressure"]), ONE_ATMOSPHERE*50)
- if("adjust_external_pressure" in signal)
- external_pressure_bound = between(0, text2num(signal["adjust_external_pressure"]), ONE_ATMOSPHERE*50)
+ if("adjust_external_pressure" in signal.data)
+ external_pressure_bound = between(0, text2num(signal.data["adjust_external_pressure"]), ONE_ATMOSPHERE*50)
- if("init" in signal)
- name = signal["init"]
+ if("init" in signal.data)
+ name = signal.data["init"]
return
- if("setting" in signal)
- pump_speed = text2num(signal["setting"])
+ if("setting" in signal.data)
+ pump_speed = text2num(signal.data["setting"])
//log_admin("DEBUG \[[world.timeofday]\]: vent_pump/receive_signal: unknown command \"[signal["command"]]\"\n[signal.debug_print()]")
spawn(2)
diff --git a/code/ATMOSPHERICS/components/unary/vent_scrubber.dm b/code/ATMOSPHERICS/components/unary/vent_scrubber.dm
index a26f82bc306..93aa24f5de0 100644
--- a/code/ATMOSPHERICS/components/unary/vent_scrubber.dm
+++ b/code/ATMOSPHERICS/components/unary/vent_scrubber.dm
@@ -20,6 +20,12 @@
var/panic = 0 //is this scrubber panicked?
var/area_uid
+
+ var/frequency = 1439
+ var/datum/radio_frequency/radio_connection
+ var/radio_filter_out
+ var/radio_filter_in
+
New()
var/area/A = get_area(loc)
if (A.master)
@@ -33,16 +39,6 @@
broadcast_status()
..()
- Del()
- var/area/alarm_area = get_area(src)
- if(alarm_area && "\"[id_tag]\"" in alarm_area.master.air_scrubbers)
- alarm_area.master.air_scrubbers.Remove("\"[id_tag]\"")
- ..()
-
- initialize()
- spawn(20)
- broadcast_status()
-
update_icon()
if(node && on && !(stat & (NOPOWER|BROKEN)))
if(scrubbing)
@@ -53,22 +49,46 @@
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off"
return
- proc/broadcast_status()
- var/area/alarm_area = get_area(src)
- if(alarm_area.master.master_air_alarm)
- if(!id_tag)
- if(alarm_area.master.master_air_alarm)
- alarm_area.master.master_air_alarm.register_env_machine(src)
- else if(!"\"[id_tag]\"" in alarm_area.air_scrubbers)
- if(alarm_area.master.master_air_alarm)
- alarm_area.master.master_air_alarm.register_env_machine(src)
- else if(stat & (NOPOWER|BROKEN))
- alarm_area.master.air_scrubbers.Remove("\"[id_tag]\"")
- return
+ proc
+ set_frequency(new_frequency)
+ radio_controller.remove_object(src, frequency)
+ frequency = new_frequency
+ radio_connection = radio_controller.add_object(src, frequency, radio_filter_in)
+
+ broadcast_status()
+ if(!radio_connection)
+ return 0
+
+ var/datum/signal/signal = new
+ signal.transmission_method = 1 //radio signal
+ signal.source = src
+ signal.data = list(
+ "area" = area_uid,
+ "tag" = id_tag,
+ "device" = "AScr",
+ "timestamp" = world.time,
+ "power" = on,
+ "scrubbing" = scrubbing,
+ "panic" = panic,
+ "filter_co2" = scrub_CO2,
+ "filter_toxins" = scrub_Toxins,
+ "filter_n2o" = scrub_N2O,
+ "sigtype" = "status"
+ )
+ radio_connection.post_signal(src, signal, radio_filter_out)
+
+ return 1
+
+ initialize()
+ ..()
+ radio_filter_in = frequency==initial(frequency)?(RADIO_FROM_AIRALARM):null
+ radio_filter_out = frequency==initial(frequency)?(RADIO_TO_AIRALARM):null
+ if (frequency)
+ set_frequency(frequency)
process()
..()
- broadcast_status()
+// broadcast_status()
if(stat & (NOPOWER|BROKEN))
return
if (!node)
@@ -142,17 +162,19 @@
return
*/
- proc/receive(var/list/signal)
+ receive_signal(datum/signal/signal)
if(stat & (NOPOWER|BROKEN))
return
+ if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
+ return 0
- if("power" in signal)
- on = text2num(signal["power"])
- if("power_toggle" in signal)
+ if("power" in signal.data)
+ on = text2num(signal.data["power"])
+ if("power_toggle" in signal.data)
on = !on
- if("panic_siphon" in signal) //must be before if("scrubbing" thing
- panic = text2num(signal["panic_siphon"])
+ if("panic_siphon" in signal.data) //must be before if("scrubbing" thing
+ panic = text2num(signal.data["panic_siphon"])
if(panic)
on = 1
scrubbing = 0
@@ -160,7 +182,7 @@
else
scrubbing = 1
volume_rate = initial(volume_rate)
- if("toggle_panic_siphon" in signal)
+ if("toggle_panic_siphon" in signal.data)
panic = !panic
if(panic)
on = 1
@@ -170,33 +192,39 @@
scrubbing = 1
volume_rate = initial(volume_rate)
- if("scrubbing" in signal)
- scrubbing = text2num(signal["scrubbing"])
- if("toggle_scrubbing" in signal)
+ if("scrubbing" in signal.data)
+ scrubbing = text2num(signal.data["scrubbing"])
+ if("toggle_scrubbing" in signal.data)
scrubbing = !scrubbing
- if("co2_scrub" in signal)
- scrub_CO2 = text2num(signal["co2_scrub"])
- if("toggle_co2_scrub" in signal)
+ if("co2_scrub" in signal.data)
+ scrub_CO2 = text2num(signal.data["co2_scrub"])
+ if("toggle_co2_scrub" in signal.data)
scrub_CO2 = !scrub_CO2
- if("tox_scrub" in signal)
- scrub_Toxins = text2num(signal["tox_scrub"])
- if("toggle_tox_scrub" in signal)
+ if("tox_scrub" in signal.data)
+ scrub_Toxins = text2num(signal.data["tox_scrub"])
+ if("toggle_tox_scrub" in signal.data)
scrub_Toxins = !scrub_Toxins
- if("n2o_scrub" in signal)
- scrub_N2O = text2num(signal["n2o_scrub"])
- if("toggle_n2o_scrub" in signal)
+ if("n2o_scrub" in signal.data)
+ scrub_N2O = text2num(signal.data["n2o_scrub"])
+ if("toggle_n2o_scrub" in signal.data)
scrub_N2O = !scrub_N2O
- if("init" in signal)
- name = signal["init"]
+ if("init" in signal.data)
+ name = signal.data["init"]
return
- if("setting" in signal)
- scrub_rate = text2num(signal["setting"])
+ if("status" in signal.data)
+ spawn(2)
+ broadcast_status()
+ return //do not update_icon
+ if("setting" in signal.data)
+ scrub_rate = text2num(signal.data["setting"])
+
+// log_admin("DEBUG \[[world.timeofday]\]: vent_scrubber/receive_signal: unknown command \"[signal.data["command"]]\"\n[signal.debug_print()]")
spawn(2)
broadcast_status()
update_icon()
diff --git a/code/WorkInProgress/Mini/atmos_control.dm b/code/WorkInProgress/Mini/atmos_control.dm
index 9c06eb7013b..553fa907001 100644
--- a/code/WorkInProgress/Mini/atmos_control.dm
+++ b/code/WorkInProgress/Mini/atmos_control.dm
@@ -63,7 +63,7 @@
"panic_siphon",
"scrubbing"
)
- current.send(device_id, list (href_list["command"] = text2num(href_list["val"])))
+ current.send_signal(device_id, list (href_list["command"] = text2num(href_list["val"])))
spawn(3)
src.updateUsrDialog()
//if("adjust_threshold") //was a good idea but required very wide window
@@ -156,19 +156,24 @@
output += "ACTIVATE PANIC SYPHON IN AREA"
if (AALARM_SCREEN_VENT)
var/sensor_data = ""
- if(current.alarm_area.air_vents.len)
- for(var/id_tag in current.alarm_area.air_vents)
- var/obj/machinery/atmospherics/unary/vent_pump/data = current.alarm_area.air_vents[id_tag]
+ if(current.alarm_area.air_vent_names.len)
+ for(var/id_tag in current.alarm_area.air_vent_names)
+ var/long_name = current.alarm_area.air_vent_names[id_tag]
+ var/list/data = current.alarm_area.air_vent_info[id_tag]
+ var/state = ""
if(!data)
- continue
+ state = " can not be found!"
+ data = list("external" = 0) //for "0" instead of empty string
+ else if (data["timestamp"]+AALARM_REPORT_TIMEOUT < world.time)
+ state = " not responding!"
sensor_data += {"
-[id_tag]
+[long_name][state]
Operating:
-[data.on?"on":"off"]
+[data["power"]?"on":"off"]
Pressure checks:
-external
-internal
+external
+internal
External pressure bound:
-
@@ -182,7 +187,7 @@
+
"}
- if (!data.pump_direction)
+ if (data["direction"] == "siphon")
sensor_data += {"
Direction:
siphoning
@@ -194,34 +199,39 @@ siphoning
output = {"Main menu
[sensor_data]"}
if (AALARM_SCREEN_SCRUB)
var/sensor_data = ""
- if(current.alarm_area.air_scrubbers.len)
- for(var/id_tag in current.alarm_area.air_scrubbers)
- var/obj/machinery/atmospherics/unary/vent_scrubber/data = current.alarm_area.air_scrubbers[id_tag]
+ if(current.alarm_area.air_scrub_names.len)
+ for(var/id_tag in current.alarm_area.air_scrub_names)
+ var/long_name = current.alarm_area.air_scrub_names[id_tag]
+ var/list/data = current.alarm_area.air_scrub_info[id_tag]
+ var/state = ""
if(!data)
- continue
+ state = " can not be found!"
+ data = list("external" = 0) //for "0" instead of empty string
+ else if (data["timestamp"]+AALARM_REPORT_TIMEOUT < world.time)
+ state = " not responding!"
sensor_data += {"
-[id_tag]
+[long_name][state]
Operating:
-[data.on?"on":"off"]
+[data["power"]?"on":"off"]
Type:
-[data.scrubbing?"scrubbing":"syphoning"]
+[data["scrubbing"]?"scrubbing":"syphoning"]
"}
if(data["scrubbing"])
sensor_data += {"
Filtering:
Carbon Dioxide
-[data.scrub_CO2?"on":"off"];
+[data["filter_co2"]?"on":"off"];
Toxins
-[data.scrub_Toxins?"on":"off"];
+[data["filter_toxins"]?"on":"off"];
Nitrous Oxide
-[data.scrub_N2O?"on":"off"]
+[data["filter_n2o"]?"on":"off"]
"}
sensor_data += {"
-Panic syphon: [data.panic?"PANIC SYPHON ACTIVATED":""]
-Dea":"red'>A")]ctivate
+Panic syphon: [data["panic"]?"PANIC SYPHON ACTIVATED":""]
+Dea":"red'>A")]ctivate