mirror of
https://github.com/ParadiseSS13/Paradise.git
synced 2026-07-20 19:44:09 +01:00
Add caching to air alarms, apcs and power monitoring computers
This commit is contained in:
@@ -31,14 +31,7 @@
|
||||
|
||||
/datum/nano_module/atmos_control/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
|
||||
var/data[0]
|
||||
var/alarms[0]
|
||||
|
||||
// TODO: Move these to a cache, similar to cameras
|
||||
for(var/obj/machinery/alarm/alarm in sortAtom((monitored_alarms.len ? monitored_alarms : machines)))
|
||||
if(!monitored_alarms.len && alarm.z != ZLEVEL_STATION && alarm.z != ZLEVEL_ASTEROID)
|
||||
continue
|
||||
alarms[++alarms.len] = alarm.get_nano_data_console()
|
||||
data["alarms"] = alarms
|
||||
data["alarms"] = air_alarm_repository.air_alarm_data(monitored_alarms)
|
||||
|
||||
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||
if(!ui)
|
||||
|
||||
@@ -13,34 +13,17 @@
|
||||
|
||||
/datum/nano_module/power_monitor/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1, var/datum/topic_state/state = default_state)
|
||||
var/data[0]
|
||||
var/pMonData[0]
|
||||
var/apcData[0]
|
||||
|
||||
data["powermonitor"] = powermonitor
|
||||
if(select_monitor)
|
||||
data["select_monitor"] = 1
|
||||
for(var/obj/machinery/computer/monitor/pMon in world)
|
||||
if( !(pMon.stat & (NOPOWER|BROKEN)) )
|
||||
pMonData[++pMonData.len] = list ("Name" = pMon.name, "ref" = "\ref[pMon]")
|
||||
data["powermonitors"] = powermonitor_repository.powermonitor_data()
|
||||
|
||||
data["powermonitors"] = pMonData
|
||||
|
||||
if (powermonitor && !isnull(powermonitor.powernet))
|
||||
if (powermonitor && !isnull(powermonitor.powernet))
|
||||
data["poweravail"] = powermonitor.powernet.avail
|
||||
data["powerload"] = num2text(powermonitor.powernet.viewload,10)
|
||||
var/list/L = list()
|
||||
for(var/obj/machinery/power/terminal/term in powermonitor.powernet.nodes)
|
||||
if(istype(term.master, /obj/machinery/power/apc))
|
||||
var/obj/machinery/power/apc/A = term.master
|
||||
L += A
|
||||
|
||||
var/list/Status = list(0,0,1,1) // Status: off, auto-off, on, auto-on
|
||||
var/list/chg = list(0,1,1) // Charging: nope, charging, full
|
||||
for(var/obj/machinery/power/apc/A in L)
|
||||
apcData[++apcData.len] = list("Name" = html_encode(A.area.name), "Equipment" = Status[A.equipment+1], "Lights" = Status[A.lighting+1], "Environment" = Status[A.environ+1], "CellPct" = A.cell ? round(A.cell.percent(),1) : -1, "CellStatus" = A.cell ? chg[A.charging+1] : 0)
|
||||
|
||||
data["apcs"] = apcData
|
||||
|
||||
data["powerload"] = num2text(powermonitor.powernet.viewload,10)
|
||||
data["apcs"] = apc_repository.apc_data(powermonitor)
|
||||
|
||||
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||
if (!ui)
|
||||
ui = new(user, src, ui_key, "power_monitor.tmpl", "Power Monitoring Console", 800, 700, state = state)
|
||||
|
||||
Reference in New Issue