From f5e1911a2e236667ac420f62c433beb3a97f756e Mon Sep 17 00:00:00 2001 From: Walter0o Date: Thu, 10 Jul 2014 18:21:00 +0200 Subject: [PATCH] fixes #5449 missing variable updating lead to APCs stuck in green status during powersinks. --- code/modules/power/apc.dm | 1 + 1 file changed, 1 insertion(+) diff --git a/code/modules/power/apc.dm b/code/modules/power/apc.dm index a8accfd0048..349f148a9b9 100644 --- a/code/modules/power/apc.dm +++ b/code/modules/power/apc.dm @@ -1169,6 +1169,7 @@ chargecount++ else chargecount = 0 + charging = 0 if(chargecount == 10)