mirror of
https://github.com/ParadiseSS13/Paradise.git
synced 2026-08-22 19:47:22 +01:00
Fixes Scrubbers and Alarms (#15358)
* Fixes Scrubbers and Alarms * true/false
This commit is contained in:
@@ -236,86 +236,58 @@
|
||||
/obj/machinery/atmospherics/unary/vent_pump/receive_signal(datum/signal/signal)
|
||||
if(stat & (NOPOWER|BROKEN))
|
||||
return
|
||||
//log_admin("DEBUG \[[world.timeofday]\]: /obj/machinery/atmospherics/unary/vent_pump/receive_signal([signal.debug_print()])")
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
if(signal.data["purge"] != null)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
|
||||
return FALSE
|
||||
|
||||
if("purge" in signal.data)
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
|
||||
if(signal.data["stabilize"] != null)
|
||||
if("stabalize" in signal.data)
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
|
||||
if(signal.data["power"] != null)
|
||||
if("power" in signal.data)
|
||||
on = text2num(signal.data["power"])
|
||||
|
||||
if(signal.data["power_toggle"] != null)
|
||||
if("power_toggle" in signal.data)
|
||||
on = !on
|
||||
|
||||
if(signal.data["checks"] != null)
|
||||
if(signal.data["checks"] == "default")
|
||||
pressure_checks = pressure_checks_default
|
||||
else
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
if("checks" in signal.data)
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
|
||||
if(signal.data["checks_toggle"] != null)
|
||||
pressure_checks = (pressure_checks?0:3)
|
||||
if("checks_toggle" in signal.data)
|
||||
pressure_checks = (pressure_checks ? 0 : 3)
|
||||
|
||||
if(signal.data["direction"] != null)
|
||||
if("direction" in signal.data)
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
|
||||
if(signal.data["set_internal_pressure"] != null)
|
||||
if(signal.data["set_internal_pressure"] == "default")
|
||||
internal_pressure_bound = internal_pressure_bound_default
|
||||
else
|
||||
internal_pressure_bound = between(
|
||||
0,
|
||||
text2num(signal.data["set_internal_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
if("set_internal_pressure" in signal.data)
|
||||
internal_pressure_bound = clamp(text2num(signal.data["set_internal_pressure"]), 0, ONE_ATMOSPHERE * 50)
|
||||
|
||||
if(signal.data["set_external_pressure"] != null)
|
||||
if(signal.data["set_external_pressure"] == "default")
|
||||
external_pressure_bound = external_pressure_bound_default
|
||||
else
|
||||
external_pressure_bound = between(
|
||||
0,
|
||||
text2num(signal.data["set_external_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
if("set_external_pressure" in signal.data)
|
||||
external_pressure_bound = clamp(text2num(signal.data["set_external_pressure"]), 0, ONE_ATMOSPHERE * 50)
|
||||
|
||||
if(signal.data["adjust_internal_pressure"] != null)
|
||||
internal_pressure_bound = between(
|
||||
0,
|
||||
internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
if("reset_external_pressure" in signal.data)
|
||||
external_pressure_bound = ONE_ATMOSPHERE
|
||||
|
||||
if(signal.data["adjust_external_pressure"] != null)
|
||||
if("adjust_internal_pressure" in signal.data)
|
||||
internal_pressure_bound = clamp(internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]), 0, ONE_ATMOSPHERE * 50)
|
||||
|
||||
if("adjust_external_pressure" in signal.data)
|
||||
external_pressure_bound = clamp(external_pressure_bound + text2num(signal.data["adjust_external_pressure"]), 0, ONE_ATMOSPHERE * 50)
|
||||
|
||||
external_pressure_bound = between(
|
||||
0,
|
||||
external_pressure_bound + text2num(signal.data["adjust_external_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["init"] != null)
|
||||
if("init" in signal.data)
|
||||
name = signal.data["init"]
|
||||
return
|
||||
|
||||
if(signal.data["status"] != null)
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
if("status" in signal.data)
|
||||
broadcast_status()
|
||||
return //do not update_icon
|
||||
|
||||
//log_admin("DEBUG \[[world.timeofday]\]: vent_pump/receive_signal: unknown command \"[signal.data["command"]]\"\n[signal.debug_print()]")
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/can_crawl_through()
|
||||
return !welded
|
||||
|
||||
@@ -41,8 +41,6 @@
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_scrubber/on
|
||||
on = TRUE
|
||||
scrub_N2O = TRUE
|
||||
scrub_Toxins = TRUE
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_scrubber/New()
|
||||
..()
|
||||
@@ -283,12 +281,12 @@
|
||||
/obj/machinery/atmospherics/unary/vent_scrubber/receive_signal(datum/signal/signal)
|
||||
if(stat & (NOPOWER|BROKEN))
|
||||
return
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"] != "command"))
|
||||
return FALSE
|
||||
|
||||
if(signal.data["power"] != null)
|
||||
if("power" in signal.data)
|
||||
on = text2num(signal.data["power"])
|
||||
if(signal.data["power_toggle"] != null)
|
||||
if("power_toggle" in signal.data)
|
||||
on = !on
|
||||
|
||||
if("widenet" in signal.data)
|
||||
@@ -296,49 +294,46 @@
|
||||
if("toggle_widenet" in signal.data)
|
||||
widenet = !widenet
|
||||
|
||||
if(signal.data["scrubbing"] != null)
|
||||
if("scrubbing" in signal.data)
|
||||
scrubbing = text2num(signal.data["scrubbing"])
|
||||
if(signal.data["toggle_scrubbing"])
|
||||
if("toggle_scrubbing" in signal.data)
|
||||
scrubbing = !scrubbing
|
||||
|
||||
if(signal.data["o2_scrub"] != null)
|
||||
if("o2_scrub" in signal.data)
|
||||
scrub_O2 = text2num(signal.data["o2_scrub"])
|
||||
if(signal.data["toggle_o2_scrub"])
|
||||
if("toggle_o2_scrub" in signal.data)
|
||||
scrub_O2 = !scrub_O2
|
||||
|
||||
if(signal.data["n2_scrub"] != null)
|
||||
if("n2_scrub" in signal.data)
|
||||
scrub_N2 = text2num(signal.data["n2_scrub"])
|
||||
if(signal.data["toggle_n2_scrub"])
|
||||
if("toggle_n2_scrub" in signal.data)
|
||||
scrub_N2 = !scrub_N2
|
||||
|
||||
if(signal.data["co2_scrub"] != null)
|
||||
if("co2_scrub" in signal.data)
|
||||
scrub_CO2 = text2num(signal.data["co2_scrub"])
|
||||
if(signal.data["toggle_co2_scrub"])
|
||||
if("toggle_co2_scrub" in signal.data)
|
||||
scrub_CO2 = !scrub_CO2
|
||||
|
||||
if(signal.data["tox_scrub"] != null)
|
||||
if("tox_scrub" in signal.data)
|
||||
scrub_Toxins = text2num(signal.data["tox_scrub"])
|
||||
if(signal.data["toggle_tox_scrub"])
|
||||
if("toggle_tox_scrub" in signal.data)
|
||||
scrub_Toxins = !scrub_Toxins
|
||||
|
||||
if(signal.data["n2o_scrub"] != null)
|
||||
if("n2o_scrub" in signal.data)
|
||||
scrub_N2O = text2num(signal.data["n2o_scrub"])
|
||||
if(signal.data["toggle_n2o_scrub"])
|
||||
if("toggle_n2o_scrub" in signal.data)
|
||||
scrub_N2O = !scrub_N2O
|
||||
|
||||
if(signal.data["init"] != null)
|
||||
if("init" in signal.data)
|
||||
name = signal.data["init"]
|
||||
return
|
||||
|
||||
if(signal.data["status"] != null)
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
if("status" in signal.data)
|
||||
broadcast_status()
|
||||
return //do not update_icon
|
||||
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_scrubber/power_change()
|
||||
var/old_stat = stat
|
||||
|
||||
Reference in New Issue
Block a user