* Fixed problems with Heat Exchanger facing
* Fixed massive problems with heat exchanger construction using the pipe dispensers
git-svn-id: http://tgstation13.googlecode.com/svn/trunk@4900 316c924e-a436-60f5-8080-3fe189b3f50e
- Readded Volume Pumps - now they work as intended and are constructable
- Readded Passive Gates - now they work as intended and are constructable
- Readded Heat Exchangers - now they work as intended and are constructable
- Added Heater - to warm up gasses to 300C
- Adjusted volumes on big tanks and portable pumps to 2000 and 1200 respectably
- Pipe dispensers can produce the readded pieces.
- Pipe construction code updated to compesate for the new items
- New graphics for all of the above - courtesy by Ausops.
git-svn-id: http://tgstation13.googlecode.com/svn/trunk@4785 316c924e-a436-60f5-8080-3fe189b3f50e
Cryo wont spit out beaker.
Fixed message "You don't have the dexterity to do this" for machinery.
PIPES:
- Heat exchange pipes are constructable now.
- Insulated pipes also were added to pipe dispenser;
- And meters too;
- Easy pipe rotating in hands;
- bent pipes actually looks bent under construction (may be glitches, please report);
- pipes now wont cover wires;
- pipes unwrenching now possible;
- large vent pumps now uses power as equipment, not environment
- pumps now uses power;
Air alarm improvements:
- all alarms in area controls all environment machines in area;
- machines initializes itself automatically and without interloping with existing ones;
- air alarms wont duplicates it air monitoring and can clear itself;
Some other typos and small issues were fixed.
git-svn-id: http://tgstation13.googlecode.com/svn/trunk@816 316c924e-a436-60f5-8080-3fe189b3f50e
Manifolds, unary vents, scrubbers, manual valves, connectors, and pumps are now also makable
testing has not been overly robust thus far
Known issues:
scrubbers don't seem to be able to grab nodes properly when constructed
runtime errors if you try making a pipe/manifold that doesn't connect to an already-constructed atmos object
corner pipe sections have a tendency to defy euclidian logic (most notable example has been a section of pipe that somehow had both ends tied to the same end of a different pipe section)
Added a disposal pipe dispenser that had been sitting unused in the code to Atmos. No clue if it actually works, I know the regular pipe dispenser worked fine
Did NOT add a pipe dispenser to the map, but it is there if admins want to spawn one
git-svn-id: http://tgstation13.googlecode.com/svn/trunk@396 316c924e-a436-60f5-8080-3fe189b3f50e