/obj/machinery/atmospherics/binary/dp_vent_pump icon = 'icons/atmos/vent_pump.dmi' icon_state = "map_dp_vent" //node2 is output port //node1 is input port req_one_access_txt = "24;10" name = "dual-port air vent" desc = "Has a valve and pump attached to it. There are two ports." level = 1 connect_types = list(1,2,3) //connects to regular, supply and scrubbers pipes var/on = 0 var/pump_direction = 1 //0 = siphoning, 1 = releasing var/external_pressure_bound = ONE_ATMOSPHERE var/input_pressure_min = 0 var/output_pressure_max = 0 var/frequency = 1439 var/id_tag = null var/datum/radio_frequency/radio_connection var/advcontrol = 0//does this device listen to the AAC settagwhitelist = list("id_tag") var/pressure_checks = 1 //1: Do not pass external_pressure_bound //2: Do not pass input_pressure_min //4: Do not pass output_pressure_max /obj/machinery/atmospherics/binary/dp_vent_pump/New() ..() if(!id_tag) assign_uid() id_tag = num2text(uid) icon = null /obj/machinery/atmospherics/binary/dp_vent_pump/initialize() ..() if(frequency) set_frequency(frequency) /obj/machinery/atmospherics/binary/dp_vent_pump/high_volume name = "large dual port air vent" /obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New() ..() air1.volume = 1000 air2.volume = 1000 /obj/machinery/atmospherics/binary/volume_pump/update_underlays() if(..()) underlays.Cut() var/turf/T = get_turf(src) if(!istype(T)) return add_underlay(T, node1, turn(dir, -180)) add_underlay(T, node2, dir) /obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0) if(!check_icon_cache()) return overlays.Cut() var/vent_icon = "vent" var/turf/T = get_turf(src) if(!istype(T)) return if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe)) vent_icon += "h" if(!powered()) vent_icon += "off" else vent_icon += "[on ? "[pump_direction ? "out" : "in"]" : "off"]" overlays += icon_manager.get_atmos_icon("device", , , vent_icon) /obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays() if(..()) underlays.Cut() var/turf/T = get_turf(src) if(!istype(T)) return if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe)) return else if(node1) add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type) else add_underlay(T, node1, turn(dir, -180)) if(node2) add_underlay(T, node2, dir, node2.icon_connect_type) else add_underlay(T, node2, dir) /obj/machinery/atmospherics/binary/dp_vent_pump/process() if(!..() || !on) return 0 var/datum/gas_mixture/environment = loc.return_air() var/environment_pressure = environment.return_pressure() if(pump_direction) //input -> external var/pressure_delta = 10000 if(pressure_checks&1) pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure)) if(pressure_checks&2) pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min)) if(pressure_delta > 0) if(air1.temperature > 0) var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION) var/datum/gas_mixture/removed = air1.remove(transfer_moles) loc.assume_air(removed) parent1.update = 1 air_update_turf() else //external -> output var/pressure_delta = 10000 if(pressure_checks&1) pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound)) if(pressure_checks&4) pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure())) if(pressure_delta > 0) if(environment.temperature > 0) var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION) var/datum/gas_mixture/removed = loc.remove_air(transfer_moles) air2.merge(removed) parent2.update = 1 air_update_turf() return 1 //Radio remote control /obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency) radio_controller.remove_object(src, frequency) frequency = new_frequency if(frequency) radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA) /obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status() if(!radio_connection) return 0 var/datum/signal/signal = new signal.transmission_method = 1 //radio signal signal.source = src signal.data = list( "tag" = id_tag, "device" = "ADVP", "power" = on, "direction" = pump_direction?("release"):("siphon"), "checks" = pressure_checks, "input" = input_pressure_min, "output" = output_pressure_max, "external" = external_pressure_bound, "sigtype" = "status" ) radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA) return 1 /obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal) if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command") || (signal.data["advcontrol"] && !advcontrol)) return 0 if(signal.data["power"] != null) on = text2num(signal.data["power"]) if(signal.data["power_toggle"] != null) on = !on if(signal.data["direction"] != null) pump_direction = text2num(signal.data["direction"]) if(signal.data["checks"] != null) pressure_checks = text2num(signal.data["checks"]) if(signal.data["purge"]) pressure_checks &= ~1 pump_direction = 0 if(signal.data["stabilize"])//the fact that this was "stabalize" shows how many fucks people give about these wonders, none pressure_checks |= 1 pump_direction = 1 if(signal.data["set_input_pressure"] != null) input_pressure_min = between( 0, text2num(signal.data["set_input_pressure"]), ONE_ATMOSPHERE*50 ) if(signal.data["set_output_pressure"] != null) output_pressure_max = between( 0, text2num(signal.data["set_output_pressure"]), ONE_ATMOSPHERE*50 ) if(signal.data["set_external_pressure"] != null) external_pressure_bound = between( 0, text2num(signal.data["set_external_pressure"]), ONE_ATMOSPHERE*50 ) if(signal.data["status"]) spawn(2) broadcast_status() return //do not update_icon spawn(2) broadcast_status() update_icon() /obj/machinery/atmospherics/binary/dp_vent_pump/attackby(var/obj/item/W as obj, var/mob/user as mob) if(istype(W, /obj/item/device/multitool)) update_multitool_menu(user) return 1 return ..() /obj/machinery/atmospherics/binary/dp_vent_pump/multitool_menu(var/mob/user,var/obj/item/device/multitool/P) return {"