Files
Paradise/code/ATMOSPHERICS/components/binary_devices/passive_gate.dm
tigercat2000 7d8c9a731a SS Conversion: Atoms, Machines, n' Mobs
This converts the machine and mob processes to the SMC. Additionally, it
adds the Atom subsystem, which handles all Initialize() calls in place
of the old gameticker. Due to incompatibility with our atmospherics
(FUCK OUR ATMOSPHERICS FOR FUCKING EVER JESUS CHRIST WHO THE FUCK MADE
THIS PIECE OF GODDAMN SHIT) atmospherics machines do not use
Initialize() as they should, instead opting for a custom atmos_init
proc that the air controller handles.
2018-04-28 17:55:15 -07:00

192 lines
5.6 KiB
Plaintext

/obj/machinery/atmospherics/binary/passive_gate
//Tries to achieve target pressure at output (like a normal pump) except
// Uses no power but can not transfer gases from a low pressure area to a high pressure area
icon = 'icons/atmos/passive_gate.dmi'
icon_state = "map"
name = "passive gate"
desc = "A one-way air valve that does not require power"
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/passive_gate/atmos_init()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/Destroy()
if(radio_controller)
radio_controller.remove_object(src, frequency)
radio_connection = null
return ..()
/obj/machinery/atmospherics/binary/passive_gate/update_icon()
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/passive_gate/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, 180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/passive_gate/process_atmos()
..()
if(!on)
return 0
var/output_starting_pressure = air2.return_pressure()
var/input_starting_pressure = air1.return_pressure()
if(output_starting_pressure >= min(target_pressure,input_starting_pressure-10))
//No need to pump gas if target is already reached or input pressure is too low
//Need at least 10 KPa difference to overcome friction in the mechanism
return 1
//Calculate necessary moles to transfer using PV = nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = min(target_pressure - output_starting_pressure, (input_starting_pressure - output_starting_pressure)/2)
//Can not have a pressure delta that would cause output_pressure > input_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/passive_gate/proc/set_frequency(new_frequency)
radio_controller.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(mob/user)
if(..())
return
if(!allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
add_fingerprint(user)
ui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/attack_ghost(mob/user)
ui_interact(user)
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state)
user.set_machine(src)
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump.tmpl", name, 385, 115, state = state)
ui.open()
/obj/machinery/atmospherics/binary/passive_gate/ui_data(mob/user)
var/list/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if(href_list["pressure"])
var/pressure = href_list["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure))
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
SSnanoui.update_uis(src)
/obj/machinery/atmospherics/binary/passive_gate/attackby(obj/item/W, mob/user, params)
if(!istype(W, /obj/item/wrench))
return ..()
if(on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1