#define APC_BREAK_PROBABILITY 25 // the probability that a given APC will be broken
/datum/event/apc_overload
var/const/announce_after_mc_ticks = 5
var/const/delayed = FALSE
var/const/event_max_duration_mc_ticks = announce_after_mc_ticks * 2
var/const/event_min_duration_mc_ticks = announce_after_mc_ticks
announceWhen = announce_after_mc_ticks
/datum/event/apc_overload/setup()
endWhen = rand(event_min_duration_mc_ticks, event_max_duration_mc_ticks)
/datum/event/apc_overload/start()
apc_overload_failure(announce=delayed)
var/sound/S = sound('sound/effects/powerloss.ogg')
for(var/mob/living/M in GLOB.player_list)
var/turf/T = get_turf(M)
if(!M.client || !is_station_level(T.z))
continue
SEND_SOUND(M, S)
/datum/event/apc_overload/announce()
GLOB.event_announcement.Announce("Overload detected in [station_name()]'s powernet. Engineering, please check all underfloor APC terminals.", "Critical Power Failure", new_sound = 'sound/AI/apc_overload.ogg')
/datum/event/apc_overload/end()
return TRUE
/proc/apc_overload_failure(announce=TRUE)
var/list/skipped_areas_apc = list(
/area/engine/engineering,
/area/turret_protected/ai)
if(announce)
GLOB.event_announcement.Announce("Overload detected in [station_name()]'s powernet. Engineering, please check all underfloor APC terminals.", "Critical Power Failure", new_sound = 'sound/AI/apc_overload.ogg')
// break APC_BREAK_PROBABILITY% of all of the APCs on the station
var/affected_apc_count = 0
for(var/thing in GLOB.apcs)
var/obj/machinery/power/apc/C = thing
// skip any APCs that are too critical to break
var/area/current_area = get_area(C)
if((current_area.type in skipped_areas_apc) || !is_station_level(C.z))
continue
// if we are going to break this one
if(prob(APC_BREAK_PROBABILITY))
// if it has a cell, drain all the charge from the cell
if(C.cell)
C.cell.charge = 0
// if it has a terminal, disconnect and delete the terminal
if(C.terminal)
var/obj/machinery/power/terminal/T = C.terminal
C.terminal.master = null
C.terminal = null
qdel(T)
// if it was operating, toggle off the breaker
if(C.operating)
C.toggle_breaker()
// no matter what, ensure the area knows something happened to the power
current_area.power_change()
affected_apc_count++
log_and_message_admins("APC Overload event deleted [affected_apc_count] underfloor APC terminals.")
#undef APC_BREAK_PROBABILITY