Increased disposal flow rate and pump power
This commit is contained in:
@@ -7,7 +7,7 @@
|
||||
// Toilets are a type of disposal bin for small objects only and work on magic. By magic, I mean torque rotation
|
||||
#define SEND_PRESSURE 700 //kPa. 7 bar - Based on existing pneumatic conveyor pressures.
|
||||
#define PRESSURE_TANK_VOLUME 70 //L - a 0.3 m diameter * 1 m long cylindrical tank. Happens to be the same volume as the regular oxygen tanks, so seems appropriate.
|
||||
#define PUMP_MAX_FLOW_RATE 50 //L/s - 2 m/s using a 15 cm by 15 cm inlet
|
||||
#define PUMP_MAX_FLOW_RATE 200 //L/s - 8 m/s using a 15 cm by 15 cm inlet
|
||||
|
||||
/obj/machinery/disposal
|
||||
name = "disposal unit"
|
||||
@@ -24,7 +24,7 @@
|
||||
var/flush_every_ticks = 30 //Every 30 ticks it will look whether it is ready to flush
|
||||
var/flush_count = 0 //this var adds 1 once per tick. When it reaches flush_every_ticks it resets and tries to flush.
|
||||
var/last_sound = 0
|
||||
active_power_usage = 1500 //the pneumatic pump power. 2 HP ~ 1500W
|
||||
active_power_usage = 2200 //the pneumatic pump power. 3 HP ~ 2200W
|
||||
idle_power_usage = 100
|
||||
|
||||