mirror of
https://github.com/PolarisSS13/Polaris.git
synced 2026-08-29 16:18:35 +01:00
In fact lets use the constants instead of bare numbers for use_power everywhere.
This commit is contained in:
@@ -1,7 +1,7 @@
|
||||
/obj/machinery/atmospherics/binary
|
||||
dir = SOUTH
|
||||
initialize_directions = SOUTH|NORTH
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
|
||||
var/datum/gas_mixture/air1
|
||||
var/datum/gas_mixture/air2
|
||||
|
||||
@@ -20,7 +20,7 @@
|
||||
|
||||
level = 1
|
||||
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
|
||||
@@ -12,7 +12,7 @@
|
||||
name = "pressure regulator"
|
||||
desc = "A one-way air valve that can be used to regulate input or output pressure, and flow rate. Does not require power."
|
||||
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
|
||||
var/unlocked = 0 //If 0, then the valve is locked closed, otherwise it is open(-able, it's a one-way valve so it closes if gas would flow backwards).
|
||||
var/target_pressure = ONE_ATMOSPHERE
|
||||
|
||||
@@ -26,7 +26,7 @@ Thus, the two variables affect pump operation are set in New():
|
||||
|
||||
//var/max_volume_transfer = 10000
|
||||
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
@@ -47,7 +47,7 @@ Thus, the two variables affect pump operation are set in New():
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/on
|
||||
icon_state = "map_on"
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/update_icon()
|
||||
|
||||
@@ -11,7 +11,7 @@
|
||||
power_rating = 15000 //15000 W ~ 20 HP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/on
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
icon_state = "map_on"
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/update_icon()
|
||||
|
||||
@@ -11,7 +11,7 @@
|
||||
var/datum/omni_port/input
|
||||
var/datum/omni_port/output
|
||||
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
|
||||
@@ -6,7 +6,7 @@
|
||||
icon_state = "map_mixer"
|
||||
pipe_state = "omni_mixer"
|
||||
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 3700 //3700 W ~ 5 HP
|
||||
|
||||
|
||||
@@ -5,7 +5,7 @@
|
||||
name = "omni device"
|
||||
icon = 'icons/atmos/omni_devices.dmi'
|
||||
icon_state = "base"
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
initialize_directions = 0
|
||||
construction_type = /obj/item/pipe/quaternary
|
||||
level = 1
|
||||
|
||||
@@ -18,7 +18,7 @@
|
||||
var/datum/pipe_network/network
|
||||
|
||||
var/on = 0
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
level = 1
|
||||
|
||||
/obj/machinery/atmospherics/portables_connector/init_dir()
|
||||
|
||||
@@ -9,7 +9,7 @@
|
||||
name = "Gas filter"
|
||||
desc = "Filters one type of gas from an input, and pushes it out the side."
|
||||
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //This also doubles as a measure of how powerful the filter is, in Watts. 7500 W ~ 10 HP
|
||||
|
||||
|
||||
@@ -8,7 +8,7 @@
|
||||
|
||||
name = "Gas mixer"
|
||||
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 3700 //This also doubles as a measure of how powerful the mixer is, in Watts. 3700 W ~ 5 HP
|
||||
|
||||
|
||||
@@ -1,7 +1,7 @@
|
||||
/obj/machinery/atmospherics/trinary
|
||||
dir = SOUTH
|
||||
initialize_directions = SOUTH|NORTH|WEST
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
pipe_flags = PIPING_DEFAULT_LAYER_ONLY|PIPING_ONE_PER_TURF
|
||||
|
||||
var/mirrored = FALSE
|
||||
|
||||
@@ -8,7 +8,7 @@
|
||||
icon_state = "freezer_0"
|
||||
density = 1
|
||||
anchored = 1
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 5 // 5 Watts for thermostat related circuitry
|
||||
circuit = /obj/item/weapon/circuitboard/unary_atmos/cooler
|
||||
|
||||
|
||||
@@ -8,7 +8,7 @@
|
||||
icon_state = "heater_0"
|
||||
density = 1
|
||||
anchored = 1
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 5 //5 Watts for thermostat related circuitry
|
||||
circuit = /obj/item/weapon/circuitboard/unary_atmos/heater
|
||||
|
||||
|
||||
@@ -10,7 +10,7 @@
|
||||
name = "air injector"
|
||||
desc = "Passively injects air into its surroundings. Has a valve attached to it that can control flow rate."
|
||||
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 15000 //15000 W ~ 20 HP
|
||||
|
||||
|
||||
@@ -14,7 +14,7 @@
|
||||
|
||||
name = "Air Vent"
|
||||
desc = "Has a valve and pump attached to it"
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
@@ -50,18 +50,18 @@
|
||||
var/datum/looping_sound/air_pump/soundloop
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/on
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
icon_state = "map_vent_out"
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/siphon
|
||||
pump_direction = 0
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/siphon/on
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
icon_state = "map_vent_in"
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/siphon/on/atmos
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
icon_state = "map_vent_in"
|
||||
external_pressure_bound = 0
|
||||
external_pressure_bound_default = 0
|
||||
|
||||
@@ -5,7 +5,7 @@
|
||||
|
||||
name = "Air Scrubber"
|
||||
desc = "Has a valve and pump attached to it"
|
||||
use_power = 0
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
@@ -29,7 +29,7 @@
|
||||
var/radio_filter_in
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_scrubber/on
|
||||
use_power = 1
|
||||
use_power = USE_POWER_IDLE
|
||||
icon_state = "map_scrubber_on"
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_scrubber/New()
|
||||
|
||||
Reference in New Issue