// TURBINE v2 AKA rev4407 Engine reborn!
|
|
|
|
// How to use it? - Mappers
|
|
//
|
|
// This is a very good power generating mechanism. All you need is a blast furnace with soaring flames and output.
|
|
// Not everything is included yet so the turbine can run out of fuel quiet quickly. The best thing about the turbine is that even
|
|
// though something is on fire that passes through it, it won't be on fire as it passes out of it. So the exhaust fumes can still
|
|
// containt unreacted fuel - plasma and oxygen that needs to be filtered out and re-routed back. This of course requires smart piping
|
|
// For a computer to work with the turbine the compressor requires a comp_id matching with the turbine computer's id. This will be
|
|
// subjected to a change in the near future mind you. Right now this method of generating power is a good backup but don't expect it
|
|
// become a main power source unless some work is done. Have fun. At 50k RPM it generates 60k power. So more than one turbine is needed!
|
|
//
|
|
// - Numbers
|
|
//
|
|
// Example setup S - sparker
|
|
// B - Blast doors into space for venting
|
|
// *BBB****BBB* C - Compressor
|
|
// S CT * T - Turbine
|
|
// * ^ * * V * D - Doors with firedoor
|
|
// **|***D**|** ^ - Fuel feed (Not vent, but a gas outlet)
|
|
// | | V - Suction vent (Like the ones in atmos
|
|
//
|
|
|
|
|
|
/obj/machinery/power/compressor
|
|
name = "compressor"
|
|
desc = "The compressor stage of a gas turbine generator."
|
|
icon = 'icons/obj/atmospherics/pipes/simple.dmi'
|
|
icon_state = "compressor"
|
|
density = TRUE
|
|
resistance_flags = FIRE_PROOF
|
|
CanAtmosPass = ATMOS_PASS_DENSITY
|
|
circuit = /obj/item/circuitboard/machine/power_compressor
|
|
var/obj/machinery/power/turbine/turbine
|
|
var/datum/gas_mixture/gas_contained
|
|
var/turf/inturf
|
|
var/starter = 0
|
|
var/rpm = 0
|
|
var/rpmtarget = 0
|
|
var/capacity = 1e6
|
|
var/comp_id = 0
|
|
var/efficiency
|
|
|
|
/obj/machinery/power/compressor/Destroy()
|
|
if(turbine && turbine.compressor == src)
|
|
turbine.compressor = null
|
|
turbine = null
|
|
return ..()
|
|
|
|
/obj/machinery/power/turbine
|
|
name = "gas turbine generator"
|
|
desc = "A gas turbine used for backup power generation."
|
|
icon = 'icons/obj/atmospherics/pipes/simple.dmi'
|
|
icon_state = "turbine"
|
|
density = TRUE
|
|
resistance_flags = FIRE_PROOF
|
|
CanAtmosPass = ATMOS_PASS_DENSITY
|
|
circuit = /obj/item/circuitboard/machine/power_turbine
|
|
var/opened = 0
|
|
var/obj/machinery/power/compressor/compressor
|
|
var/turf/outturf
|
|
var/lastgen
|
|
var/productivity = 1
|
|
|
|
/obj/machinery/power/turbine/Destroy()
|
|
if(compressor && compressor.turbine == src)
|
|
compressor.turbine = null
|
|
compressor = null
|
|
return ..()
|
|
|
|
// the inlet stage of the gas turbine electricity generator
|
|
|
|
/obj/machinery/power/compressor/Initialize(mapload)
|
|
. = ..()
|
|
// The inlet of the compressor is the direction it faces
|
|
gas_contained = new
|
|
inturf = get_step(src, dir)
|
|
locate_machinery()
|
|
if(!turbine)
|
|
obj_break()
|
|
|
|
#define COMPFRICTION 5e5
|
|
|
|
/obj/machinery/power/compressor/locate_machinery()
|
|
if(turbine)
|
|
return
|
|
turbine = locate() in get_step(src, get_dir(inturf, src))
|
|
if(turbine)
|
|
turbine.locate_machinery()
|
|
|
|
/obj/machinery/power/compressor/RefreshParts()
|
|
var/E = 0
|
|
for(var/obj/item/stock_parts/manipulator/M in component_parts)
|
|
E += M.rating
|
|
efficiency = E / 6
|
|
|
|
/obj/machinery/power/compressor/examine(mob/user)
|
|
. = ..()
|
|
if(in_range(user, src) || isobserver(user))
|
|
. += "<span class='notice'>The status display reads: Efficiency at <b>[efficiency*100]%</b>.</span>"
|
|
|
|
/obj/machinery/power/compressor/attackby(obj/item/I, mob/user, params)
|
|
if(default_deconstruction_screwdriver(user, initial(icon_state), initial(icon_state), I))
|
|
return
|
|
|
|
if(default_change_direction_wrench(user, I))
|
|
turbine = null
|
|
inturf = get_step(src, dir)
|
|
locate_machinery()
|
|
if(turbine)
|
|
to_chat(user, "<span class='notice'>Turbine connected.</span>")
|
|
stat &= ~BROKEN
|
|
else
|
|
to_chat(user, "<span class='alert'>Turbine not connected.</span>")
|
|
obj_break()
|
|
return
|
|
|
|
default_deconstruction_crowbar(I)
|
|
|
|
/obj/machinery/power/compressor/process()
|
|
if(!starter)
|
|
return
|
|
if(!turbine || (turbine.stat & BROKEN))
|
|
starter = FALSE
|
|
if(stat & BROKEN || panel_open)
|
|
starter = FALSE
|
|
return
|
|
cut_overlays()
|
|
|
|
rpm = 0.9* rpm + 0.1 * rpmtarget
|
|
// It's a simplified version taking only 1/10 of the moles from the turf nearby. It should be later changed into a better version
|
|
// above todo 7 years and counting
|
|
|
|
inturf.transfer_air_ratio(gas_contained, 0.1)
|
|
|
|
// RPM function to include compression friction - be advised that too low/high of a compfriction value can make things screwy
|
|
|
|
rpm = min(rpm, (COMPFRICTION*efficiency)/2)
|
|
rpm = max(0, rpm - (rpm*rpm)/(COMPFRICTION*efficiency))
|
|
|
|
if(starter && !(stat & NOPOWER))
|
|
use_power(2800)
|
|
if(rpm<1000)
|
|
rpmtarget = 1000
|
|
else
|
|
if(rpm<1000)
|
|
rpmtarget = 0
|
|
|
|
if(rpm>50000)
|
|
add_overlay(mutable_appearance(icon, "comp-o4", FLY_LAYER))
|
|
else if(rpm>10000)
|
|
add_overlay(mutable_appearance(icon, "comp-o3", FLY_LAYER))
|
|
else if(rpm>2000)
|
|
add_overlay(mutable_appearance(icon, "comp-o2", FLY_LAYER))
|
|
else if(rpm>500)
|
|
add_overlay(mutable_appearance(icon, "comp-o1", FLY_LAYER))
|
|
//TODO: DEFERRED
|
|
|
|
// These are crucial to working of a turbine - the stats modify the power output. TurbGenQ modifies how much raw energy can you get from
|
|
// rpms, TurbGenG modifies the shape of the curve - the lower the value the less straight the curve is.
|
|
|
|
#define TURBGENQ 100000
|
|
#define TURBGENG 0.5
|
|
|
|
/obj/machinery/power/turbine/Initialize(mapload)
|
|
. = ..()
|
|
// The outlet is pointed at the direction of the turbine component
|
|
outturf = get_step(src, dir)
|
|
locate_machinery()
|
|
if(!compressor)
|
|
obj_break()
|
|
connect_to_network()
|
|
|
|
/obj/machinery/power/turbine/RefreshParts()
|
|
var/P = 0
|
|
for(var/obj/item/stock_parts/capacitor/C in component_parts)
|
|
P += C.rating
|
|
productivity = P / 6
|
|
|
|
/obj/machinery/power/turbine/examine(mob/user)
|
|
. = ..()
|
|
if(in_range(user, src) || isobserver(user))
|
|
. += "<span class='notice'>The status display reads: Productivity at <b>[productivity*100]%</b>.</span>"
|
|
|
|
/obj/machinery/power/turbine/locate_machinery()
|
|
if(compressor)
|
|
return
|
|
compressor = locate() in get_step(src, get_dir(outturf, src))
|
|
if(compressor)
|
|
compressor.locate_machinery()
|
|
|
|
/obj/machinery/power/turbine/process()
|
|
|
|
if(!compressor)
|
|
stat = BROKEN
|
|
|
|
if((stat & BROKEN) || panel_open)
|
|
return
|
|
if(!compressor.starter)
|
|
return
|
|
cut_overlays()
|
|
|
|
// This is the power generation function. If anything is needed it's good to plot it in EXCEL before modifying
|
|
// the TURBGENQ and TURBGENG values
|
|
|
|
lastgen = ((compressor.rpm / TURBGENQ)**TURBGENG) * TURBGENQ * productivity
|
|
|
|
add_avail(lastgen)
|
|
|
|
// Weird function but it works. Should be something else...
|
|
|
|
var/newrpm = ((compressor.gas_contained.return_temperature()) * compressor.gas_contained.total_moles())/4
|
|
|
|
newrpm = max(0, newrpm)
|
|
|
|
if(!compressor.starter || newrpm > 1000)
|
|
compressor.rpmtarget = newrpm
|
|
|
|
if(compressor.gas_contained.total_moles()>0)
|
|
var/oamount = min(compressor.gas_contained.total_moles(), (compressor.rpm+100)/35000*compressor.capacity)
|
|
outturf.assume_air_moles(compressor.gas_contained, oamount)
|
|
|
|
// If it works, put an overlay that it works!
|
|
|
|
if(lastgen > 100)
|
|
add_overlay(mutable_appearance(icon, "turb-o", FLY_LAYER))
|
|
|
|
/obj/machinery/power/turbine/attackby(obj/item/I, mob/user, params)
|
|
if(default_deconstruction_screwdriver(user, initial(icon_state), initial(icon_state), I))
|
|
return
|
|
|
|
if(default_change_direction_wrench(user, I))
|
|
compressor = null
|
|
outturf = get_step(src, dir)
|
|
locate_machinery()
|
|
if(compressor)
|
|
to_chat(user, "<span class='notice'>Compressor connected.</span>")
|
|
stat &= ~BROKEN
|
|
else
|
|
to_chat(user, "<span class='alert'>Compressor not connected.</span>")
|
|
obj_break()
|
|
return
|
|
|
|
default_deconstruction_crowbar(I)
|
|
|
|
/obj/machinery/power/turbine/ui_interact(mob/user, datum/tgui/ui)
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "TurbineComputer", name)
|
|
ui.open()
|
|
|
|
/obj/machinery/power/turbine/ui_data(mob/user)
|
|
var/list/data = list()
|
|
data["compressor"] = compressor ? TRUE : FALSE
|
|
data["compressor_broke"] = (!compressor || (compressor.stat & BROKEN)) ? TRUE : FALSE
|
|
data["turbine"] = compressor?.turbine ? TRUE : FALSE
|
|
data["turbine_broke"] = (!compressor || !compressor.turbine || (compressor.turbine.stat & BROKEN)) ? TRUE : FALSE
|
|
data["online"] = compressor?.starter
|
|
data["power"] = DisplayPower(compressor?.turbine?.lastgen)
|
|
data["rpm"] = compressor?.rpm
|
|
data["temp"] = compressor?.gas_contained.return_temperature()
|
|
return data
|
|
|
|
/obj/machinery/power/turbine/ui_act(action, params)
|
|
if(..())
|
|
return
|
|
|
|
switch(action)
|
|
if("toggle_power")
|
|
if(compressor && compressor.turbine)
|
|
compressor.starter = !compressor.starter
|
|
. = TRUE
|
|
if("reconnect")
|
|
locate_machinery()
|
|
. = TRUE
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
|
|
// COMPUTER NEEDS A SERIOUS REWRITE.
|
|
|
|
/obj/machinery/computer/turbine_computer
|
|
name = "gas turbine control computer"
|
|
desc = "A computer to remotely control a gas turbine."
|
|
icon_screen = "turbinecomp"
|
|
icon_keyboard = "tech_key"
|
|
circuit = /obj/item/circuitboard/computer/turbine_computer
|
|
var/obj/machinery/power/compressor/compressor
|
|
var/id = 0
|
|
|
|
/obj/machinery/computer/turbine_computer/Initialize(mapload)
|
|
. = ..()
|
|
return INITIALIZE_HINT_LATELOAD
|
|
|
|
/obj/machinery/computer/turbine_computer/LateInitialize()
|
|
locate_machinery()
|
|
|
|
/obj/machinery/computer/turbine_computer/locate_machinery()
|
|
if(id)
|
|
for(var/obj/machinery/power/compressor/C in GLOB.machines)
|
|
if(C.comp_id == id)
|
|
compressor = C
|
|
return
|
|
else
|
|
compressor = locate(/obj/machinery/power/compressor) in range(7, src)
|
|
|
|
/obj/machinery/computer/turbine_computer/ui_interact(mob/user, datum/tgui/ui)
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "TurbineComputer", name)
|
|
ui.open()
|
|
|
|
/obj/machinery/computer/turbine_computer/ui_data(mob/user)
|
|
var/list/data = list()
|
|
data["compressor"] = compressor ? TRUE : FALSE
|
|
data["compressor_broke"] = (!compressor || (compressor.stat & BROKEN)) ? TRUE : FALSE
|
|
data["turbine"] = compressor?.turbine ? TRUE : FALSE
|
|
data["turbine_broke"] = (!compressor || !compressor.turbine || (compressor.turbine.stat & BROKEN)) ? TRUE : FALSE
|
|
data["online"] = compressor?.starter
|
|
data["power"] = DisplayPower(compressor?.turbine?.lastgen)
|
|
data["rpm"] = compressor?.rpm
|
|
data["temp"] = compressor?.gas_contained.return_temperature()
|
|
|
|
return data
|
|
|
|
/obj/machinery/computer/turbine_computer/ui_act(action, params)
|
|
if(..())
|
|
return
|
|
|
|
switch(action)
|
|
if("toggle_power")
|
|
if(compressor && compressor.turbine)
|
|
compressor.starter = !compressor.starter
|
|
. = TRUE
|
|
if("reconnect")
|
|
locate_machinery()
|
|
. = TRUE
|
|
|
|
#undef COMPFRICTION
|
|
#undef TURBGENQ
|
|
#undef TURBGENG
|