//normal computer version is located in code\modules\power\monitor.dm, /obj/machinery/computer/monitor
|
|
|
|
/datum/computer_file/program/power_monitor
|
|
filename = "ampcheck"
|
|
filedesc = "AmpCheck"
|
|
program_icon_state = "power_monitor"
|
|
extended_desc = "This program connects to sensors around the station to provide information about electrical systems"
|
|
ui_header = "power_norm.gif"
|
|
transfer_access = ACCESS_ENGINE
|
|
usage_flags = PROGRAM_CONSOLE
|
|
requires_ntnet = 0
|
|
size = 9
|
|
tgui_id = "NtosPowerMonitor"
|
|
|
|
var/has_alert = 0
|
|
var/obj/structure/cable/attached_wire
|
|
var/obj/machinery/power/apc/local_apc
|
|
var/list/history = list()
|
|
var/record_size = 60
|
|
var/record_interval = 50
|
|
var/next_record = 0
|
|
|
|
|
|
/datum/computer_file/program/power_monitor/run_program(mob/living/user)
|
|
. = ..(user)
|
|
search()
|
|
history["supply"] = list()
|
|
history["demand"] = list()
|
|
|
|
|
|
/datum/computer_file/program/power_monitor/process_tick()
|
|
if(!get_powernet())
|
|
search()
|
|
else
|
|
record()
|
|
|
|
/datum/computer_file/program/power_monitor/proc/search() //keep in sync with /obj/machinery/computer/monitor's version
|
|
var/turf/T = get_turf(computer)
|
|
attached_wire = locate(/obj/structure/cable) in T
|
|
if(attached_wire)
|
|
return
|
|
var/area/A = get_area(computer) //if the computer isn't directly connected to a wire, attempt to find the APC powering it to pull it's powernet instead
|
|
if(!A)
|
|
return
|
|
local_apc = A.get_apc()
|
|
if(!local_apc)
|
|
return
|
|
if(!local_apc.terminal) //this really shouldn't happen without badminnery.
|
|
local_apc = null
|
|
|
|
/datum/computer_file/program/power_monitor/proc/get_powernet() //keep in sync with /obj/machinery/computer/monitor's version
|
|
if(attached_wire || (local_apc && local_apc.terminal))
|
|
return attached_wire ? attached_wire.powernet : local_apc.terminal.powernet
|
|
return FALSE
|
|
|
|
/datum/computer_file/program/power_monitor/proc/record() //keep in sync with /obj/machinery/computer/monitor's version
|
|
if(world.time >= next_record)
|
|
next_record = world.time + record_interval
|
|
|
|
var/datum/powernet/connected_powernet = get_powernet()
|
|
|
|
var/list/supply = history["supply"]
|
|
if(connected_powernet)
|
|
supply += connected_powernet.viewavail
|
|
if(supply.len > record_size)
|
|
supply.Cut(1, 2)
|
|
|
|
var/list/demand = history["demand"]
|
|
if(connected_powernet)
|
|
demand += connected_powernet.viewload
|
|
if(demand.len > record_size)
|
|
demand.Cut(1, 2)
|
|
|
|
/datum/computer_file/program/power_monitor/ui_data()
|
|
var/datum/powernet/connected_powernet = get_powernet()
|
|
var/list/data = get_header_data()
|
|
data["stored"] = record_size
|
|
data["interval"] = record_interval / 10
|
|
data["attached"] = connected_powernet ? TRUE : FALSE
|
|
if(connected_powernet)
|
|
data["supply"] = DisplayPower(connected_powernet.viewavail)
|
|
data["demand"] = DisplayPower(connected_powernet.viewload)
|
|
data["history"] = history
|
|
|
|
data["areas"] = list()
|
|
if(connected_powernet)
|
|
for(var/obj/machinery/power/terminal/term in connected_powernet.nodes)
|
|
var/obj/machinery/power/apc/A = term.master
|
|
if(istype(A))
|
|
data["areas"] += list(list(
|
|
"name" = A.area.name,
|
|
"charge" = A.cell ? A.cell.percent() : 0,
|
|
"load" = DisplayPower(A.lastused_total),
|
|
"charging" = A.charging,
|
|
"eqp" = A.equipment,
|
|
"lgt" = A.lighting,
|
|
"env" = A.environ
|
|
))
|
|
|
|
return data
|
|
|