/datum/tlv
var/min2
var/min1
var/max1
var/max2
/datum/tlv/New(min2 as num, min1 as num, max1 as num, max2 as num)
src.min2 = min2
src.min1 = min1
src.max1 = max1
src.max2 = max2
/datum/tlv/proc/get_danger_level(val as num)
if(max2 != -1 && val >= max2)
return 2
if(min2 != -1 && val <= min2)
return 2
if(max1 != -1 && val >= max1)
return 1
if(min1 != -1 && val <= min1)
return 1
return 0
/obj/item/weapon/electronics/airalarm
name = "air alarm electronics"
icon_state = "airalarm_electronics"
/obj/item/wallframe/airalarm
name = "air alarm frame"
desc = "Used for building Air Alarms"
icon = 'icons/obj/monitors.dmi'
icon_state = "alarm_bitem"
result_path = /obj/machinery/airalarm
#define AALARM_MODE_SCRUBBING 1
#define AALARM_MODE_VENTING 2 //makes draught
#define AALARM_MODE_PANIC 3 //like siphon, but stronger (enables widenet)
#define AALARM_MODE_REPLACEMENT 4 //sucks off all air, then refill and swithes to scrubbing
#define AALARM_MODE_OFF 5
#define AALARM_MODE_FLOOD 6 //Emagged mode; turns off scrubbers and pressure checks on vents
#define AALARM_MODE_SIPHON 7 //Scrubbers suck air
#define AALARM_MODE_CONTAMINATED 8 //Turns on all filtering and widenet scrubbing.
#define AALARM_MODE_REFILL 9 //just like normal, but with triple the air output
#define AALARM_REPORT_TIMEOUT 100
/obj/machinery/airalarm
name = "air alarm"
desc = "A machine that monitors atmosphere levels. Goes off if the area is dangerous."
icon = 'icons/obj/monitors.dmi'
icon_state = "alarm0"
anchored = TRUE
use_power = IDLE_POWER_USE
idle_power_usage = 4
active_power_usage = 8
power_channel = ENVIRON
req_access = list(ACCESS_ATMOSPHERICS)
max_integrity = 250
integrity_failure = 80
armor = list(melee = 0, bullet = 0, laser = 0, energy = 100, bomb = 0, bio = 100, rad = 100, fire = 90, acid = 30)
resistance_flags = FIRE_PROOF
var/danger_level = 0
var/mode = AALARM_MODE_SCRUBBING
var/locked = TRUE
var/aidisabled = 0
var/shorted = 0
var/buildstage = 2 // 2 = complete, 1 = no wires, 0 = circuit gone
var/frequency = 1439
var/alarm_frequency = 1437
var/datum/radio_frequency/radio_connection
var/list/TLV = list( // Breathable air.
"pressure" = new/datum/tlv(ONE_ATMOSPHERE * 0.80, ONE_ATMOSPHERE* 0.90, ONE_ATMOSPHERE * 1.10, ONE_ATMOSPHERE * 1.20), // kPa
"temperature" = new/datum/tlv(T0C, T0C+10, T0C+40, T0C+66), // K
"o2" = new/datum/tlv(16, 19, 135, 140), // Partial pressure, kpa
"n2" = new/datum/tlv(-1, -1, 1000, 1000), // Partial pressure, kpa
"co2" = new/datum/tlv(-1, -1, 5, 10), // Partial pressure, kpa
"plasma" = new/datum/tlv(-1, -1, 0.2, 0.5), // Partial pressure, kpa
"n2o" = new/datum/tlv(-1, -1, 0.2, 0.5), // Partial pressure, kpa
"bz" = new/datum/tlv(-1, -1, 0.2, 0.5),
"freon" = new/datum/tlv(-1, -1, 0.2, 0.5),
"water_vapor" = new/datum/tlv(-1, -1, 0.2, 0.5)
)
/obj/machinery/airalarm/server // No checks here.
TLV = list(
"pressure" = new/datum/tlv(-1, -1, -1, -1),
"temperature" = new/datum/tlv(-1, -1, -1, -1),
"o2" = new/datum/tlv(-1, -1, -1, -1),
"n2" = new/datum/tlv(-1, -1, -1, -1),
"co2" = new/datum/tlv(-1, -1, -1, -1),
"plasma" = new/datum/tlv(-1, -1, -1, -1),
"n2o" = new/datum/tlv(-1, -1, -1, -1),
"bz" = new/datum/tlv(-1, -1, -1, -1),
"freon" = new/datum/tlv(-1, -1, -1, -1),
"water_vapor" = new/datum/tlv(-1, -1, -1, -1)
)
/obj/machinery/airalarm/kitchen_cold_room // Copypasta: to check temperatures.
TLV = list(
"pressure" = new/datum/tlv(ONE_ATMOSPHERE * 0.80, ONE_ATMOSPHERE* 0.90, ONE_ATMOSPHERE * 1.10, ONE_ATMOSPHERE * 1.20), // kPa
"temperature" = new/datum/tlv(200,210,273.15,283.15), // K
"o2" = new/datum/tlv(16, 19, 135, 140), // Partial pressure, kpa
"n2" = new/datum/tlv(-1, -1, 1000, 1000), // Partial pressure, kpa
"co2" = new/datum/tlv(-1, -1, 5, 10), // Partial pressure, kpa
"plasma" = new/datum/tlv(-1, -1, 0.2, 0.5), // Partial pressure, kpa
"n2o" = new/datum/tlv(-1, -1, 0.2, 0.5), // Partial pressure, kpa
"bz" = new/datum/tlv(-1, -1, 0.2, 0.5), // Partial pressure, kpa
"freon" = new/datum/tlv(-1, -1, 0.2, 0.5), // Partial pressure, kpa
"water_vapor" = new/datum/tlv(-1, -1, 0.2, 0.5)
)
/obj/machinery/airalarm/engine
name = "engine air alarm"
locked = FALSE
req_access = null
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_ENGINE)
/obj/machinery/airalarm/all_access
name = "all-access air alarm"
desc = "This particular atmos control unit appears to have no access restrictions."
locked = FALSE
req_access = null
req_one_access = null
//all air alarms in area are connected via magic
/area
var/list/air_vent_names = list()
var/list/air_scrub_names = list()
var/list/air_vent_info = list()
var/list/air_scrub_info = list()
/obj/machinery/airalarm/New(loc, ndir, nbuild)
..()
wires = new /datum/wires/airalarm(src)
if(ndir)
setDir(ndir)
if(nbuild)
buildstage = 0
panel_open = TRUE
pixel_x = (dir & 3)? 0 : (dir == 4 ? -24 : 24)
pixel_y = (dir & 3)? (dir == 1 ? -24 : 24) : 0
var/area/A = get_area(src)
if(name == initial(name))
name = "[A.name] Air Alarm"
update_icon()
/obj/machinery/airalarm/Destroy()
SSradio.remove_object(src, frequency)
qdel(wires)
wires = null
return ..()
/obj/machinery/airalarm/Initialize(mapload)
..()
set_frequency(frequency)
/obj/machinery/airalarm/ui_status(mob/user)
if(user.has_unlimited_silicon_privilege && aidisabled)
to_chat(user, "AI control has been disabled.")
else if(!shorted)
return ..()
return UI_CLOSE
/obj/machinery/airalarm/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "airalarm", name, 440, 650, master_ui, state)
ui.open()
/obj/machinery/airalarm/ui_data(mob/user)
var/data = list(
"locked" = locked,
"siliconUser" = user.has_unlimited_silicon_privilege,
"emagged" = emagged,
"danger_level" = danger_level,
)
var/area/A = get_area(src)
data["atmos_alarm"] = A.atmosalm
data["fire_alarm"] = A.fire
var/turf/T = get_turf(src)
var/datum/gas_mixture/environment = T.return_air()
var/datum/tlv/cur_tlv
data["environment_data"] = list()
var/pressure = environment.return_pressure()
cur_tlv = TLV["pressure"]
data["environment_data"] += list(list(
"name" = "Pressure",
"value" = pressure,
"unit" = "kPa",
"danger_level" = cur_tlv.get_danger_level(pressure)
))
var/temperature = environment.temperature
cur_tlv = TLV["temperature"]
data["environment_data"] += list(list(
"name" = "Temperature",
"value" = temperature,
"unit" = "K ([round(temperature - T0C, 0.1)]C)",
"danger_level" = cur_tlv.get_danger_level(temperature)
))
var/total_moles = environment.total_moles()
var/partial_pressure = R_IDEAL_GAS_EQUATION * environment.temperature / environment.volume
for(var/gas_id in environment.gases)
if(!(gas_id in TLV)) // We're not interested in this gas, it seems.
continue
cur_tlv = TLV[gas_id]
data["environment_data"] += list(list(
"name" = environment.gases[gas_id][GAS_META][META_GAS_NAME],
"value" = environment.gases[gas_id][MOLES] / total_moles * 100,
"unit" = "%",
"danger_level" = cur_tlv.get_danger_level(environment.gases[gas_id][MOLES] * partial_pressure)
))
if(!locked || user.has_unlimited_silicon_privilege)
data["vents"] = list()
for(var/id_tag in A.air_vent_names)
var/long_name = A.air_vent_names[id_tag]
var/list/info = A.air_vent_info[id_tag]
if(!info || info["frequency"] != frequency)
continue
data["vents"] += list(list(
"id_tag" = id_tag,
"long_name" = sanitize(long_name),
"power" = info["power"],
"checks" = info["checks"],
"excheck" = info["checks"]&1,
"incheck" = info["checks"]&2,
"direction" = info["direction"],
"external" = info["external"],
"extdefault"= (info["external"] == ONE_ATMOSPHERE)
))
data["scrubbers"] = list()
for(var/id_tag in A.air_scrub_names)
var/long_name = A.air_scrub_names[id_tag]
var/list/info = A.air_scrub_info[id_tag]
if(!info || info["frequency"] != frequency)
continue
data["scrubbers"] += list(list(
"id_tag" = id_tag,
"long_name" = sanitize(long_name),
"power" = info["power"],
"scrubbing" = info["scrubbing"],
"widenet" = info["widenet"],
"filter_co2" = info["filter_co2"],
"filter_toxins" = info["filter_toxins"],
"filter_n2o" = info["filter_n2o"],
"filter_bz" = info["filter_bz"],
"filter_freon" = info["filter_freon"],
"filter_water_vapor" = info["filter_water_vapor"]
))
data["mode"] = mode
data["modes"] = list()
data["modes"] += list(list("name" = "Filtering - Scrubs out contaminants", "mode" = AALARM_MODE_SCRUBBING, "selected" = mode == AALARM_MODE_SCRUBBING, "danger" = 0))
data["modes"] += list(list("name" = "Contaminated - Scrubs out ALL contaminants quickly","mode" = AALARM_MODE_CONTAMINATED, "selected" = mode == AALARM_MODE_CONTAMINATED, "danger" = 0))
data["modes"] += list(list("name" = "Draught - Siphons out air while replacing", "mode" = AALARM_MODE_VENTING, "selected" = mode == AALARM_MODE_VENTING, "danger" = 0))
data["modes"] += list(list("name" = "Refill - Triple vent output", "mode" = AALARM_MODE_REFILL, "selected" = mode == AALARM_MODE_REFILL, "danger" = 1))
data["modes"] += list(list("name" = "Cycle - Siphons air before replacing", "mode" = AALARM_MODE_REPLACEMENT, "selected" = mode == AALARM_MODE_REPLACEMENT, "danger" = 1))
data["modes"] += list(list("name" = "Siphon - Siphons air out of the room", "mode" = AALARM_MODE_SIPHON, "selected" = mode == AALARM_MODE_SIPHON, "danger" = 1))
data["modes"] += list(list("name" = "Panic Siphon - Siphons air out of the room quickly","mode" = AALARM_MODE_PANIC, "selected" = mode == AALARM_MODE_PANIC, "danger" = 1))
data["modes"] += list(list("name" = "Off - Shuts off vents and scrubbers", "mode" = AALARM_MODE_OFF, "selected" = mode == AALARM_MODE_OFF, "danger" = 0))
if(emagged)
data["modes"] += list(list("name" = "Flood - Shuts off scrubbers and opens vents", "mode" = AALARM_MODE_FLOOD, "selected" = mode == AALARM_MODE_FLOOD, "danger" = 1))
var/datum/tlv/selected
var/list/thresholds = list()
selected = TLV["pressure"]
thresholds += list(list("name" = "Pressure", "settings" = list()))
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "min2", "selected" = selected.min2))
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "min1", "selected" = selected.min1))
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "max1", "selected" = selected.max1))
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "max2", "selected" = selected.max2))
selected = TLV["temperature"]
thresholds += list(list("name" = "Temperature", "settings" = list()))
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "min2", "selected" = selected.min2))
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "min1", "selected" = selected.min1))
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "max1", "selected" = selected.max1))
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "max2", "selected" = selected.max2))
for(var/gas_id in GLOB.meta_gas_info)
if(!(gas_id in TLV)) // We're not interested in this gas, it seems.
continue
selected = TLV[gas_id]
thresholds += list(list("name" = GLOB.meta_gas_info[gas_id][META_GAS_NAME], "settings" = list()))
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "min2", "selected" = selected.min2))
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "min1", "selected" = selected.min1))
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "max1", "selected" = selected.max1))
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "max2", "selected" = selected.max2))
data["thresholds"] = thresholds
return data
/obj/machinery/airalarm/ui_act(action, params)
if(..() || buildstage != 2)
return
if((locked && !usr.has_unlimited_silicon_privilege) || (usr.has_unlimited_silicon_privilege && aidisabled))
return
var/device_id = params["id_tag"]
switch(action)
if("lock")
if(usr.has_unlimited_silicon_privilege && !wires.is_cut(WIRE_IDSCAN))
locked = !locked
. = TRUE
if("power", "co2_scrub", "tox_scrub", "n2o_scrub", "bz_scrub", "freon_scrub","water_vapor_scrub", "widenet", "scrubbing")
send_signal(device_id, list("[action]" = text2num(params["val"])))
. = TRUE
if("excheck")
send_signal(device_id, list("checks" = text2num(params["val"])^1))
. = TRUE
if("incheck")
send_signal(device_id, list("checks" = text2num(params["val"])^2))
. = TRUE
if("set_external_pressure")
var/area/A = get_area(src)
var/target = input("New target pressure:", name, A.air_vent_info[device_id]["external"]) as num|null
if(!isnull(target) && !..())
send_signal(device_id, list("set_external_pressure" = target))
. = TRUE
if("reset_external_pressure")
send_signal(device_id, list("reset_external_pressure"))
. = TRUE
if("threshold")
var/env = params["env"]
var/name = params["var"]
var/datum/tlv/tlv = TLV[env]
if(isnull(tlv))
return
var/value = input("New [name] for [env]:", name, tlv.vars[name]) as num|null
if(!isnull(value) && !..())
if(value < 0)
tlv.vars[name] = -1
else
tlv.vars[name] = round(value, 0.01)
. = TRUE
if("mode")
mode = text2num(params["mode"])
apply_mode()
. = TRUE
if("alarm")
var/area/A = get_area(src)
if(A.atmosalert(2, src))
post_alert(2)
. = TRUE
if("reset")
var/area/A = get_area(src)
if(A.atmosalert(0, src))
post_alert(0)
. = TRUE
update_icon()
/obj/machinery/airalarm/proc/reset(wire)
switch(wire)
if(WIRE_POWER)
if(!wires.is_cut(WIRE_POWER))
shorted = FALSE
update_icon()
if(WIRE_AI)
if(!wires.is_cut(WIRE_AI))
aidisabled = FALSE
/obj/machinery/airalarm/proc/shock(mob/user, prb)
if((stat & (NOPOWER))) // unpowered, no shock
return 0
if(!prob(prb))
return 0 //you lucked out, no shock for you
var/datum/effect_system/spark_spread/s = new /datum/effect_system/spark_spread
s.set_up(5, 1, src)
s.start() //sparks always.
if (electrocute_mob(user, get_area(src), src, 1, TRUE))
return 1
else
return 0
/obj/machinery/airalarm/proc/refresh_all()
var/area/A = get_area(src)
for(var/id_tag in A.air_vent_names)
var/list/I = A.air_vent_info[id_tag]
if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time)
continue
send_signal(id_tag, list("status"))
for(var/id_tag in A.air_scrub_names)
var/list/I = A.air_scrub_info[id_tag]
if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time)
continue
send_signal(id_tag, list("status"))
/obj/machinery/airalarm/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_TO_AIRALARM)
/obj/machinery/airalarm/proc/send_signal(target, list/command)//sends signal 'command' to 'target'. Returns 0 if no radio connection, 1 otherwise
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = command
signal.data["tag"] = target
signal.data["sigtype"] = "command"
radio_connection.post_signal(src, signal, GLOB.RADIO_FROM_AIRALARM)
// to_chat(world, text("Signal [] Broadcasted to []", command, target))
return 1
/obj/machinery/airalarm/proc/apply_mode()
var/area/A = get_area(src)
switch(mode)
if(AALARM_MODE_SCRUBBING)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"co2_scrub" = 1,
"tox_scrub" = 0,
"n2o_scrub" = 0,
"bz_scrub" = 0,
"freon_scrub"= 0,
"water_vapor_scrub"= 0,
"scrubbing" = 1,
"widenet" = 0,
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE
))
if(AALARM_MODE_CONTAMINATED)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"co2_scrub" = 1,
"tox_scrub" = 1,
"n2o_scrub" = 1,
"bz_scrub" = 1,
"freon_scrub"= 1,
"water_vapor_scrub"= 1,
"scrubbing" = 1,
"widenet" = 1,
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE
))
if(AALARM_MODE_VENTING)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"widenet" = 0,
"scrubbing" = 0
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE*2
))
if(AALARM_MODE_REFILL)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"co2_scrub" = 1,
"tox_scrub" = 0,
"n2o_scrub" = 0,
"bz_scrub" = 0,
"freon_scrub"= 0,
"water_vapor_scrub"= 0,
"scrubbing" = 1,
"widenet" = 0,
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE * 3
))
if(AALARM_MODE_PANIC,
AALARM_MODE_REPLACEMENT)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"widenet" = 1,
"scrubbing" = 0
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 0
))
if(AALARM_MODE_SIPHON)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"widenet" = 0,
"scrubbing" = 0
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 0
))
if(AALARM_MODE_OFF)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 0
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 0
))
if(AALARM_MODE_FLOOD)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 0
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 1,
"checks" = 2,
"set_internal_pressure" = 0
))
/obj/machinery/airalarm/update_icon()
if(panel_open)
switch(buildstage)
if(2)
icon_state = "alarmx"
if(1)
icon_state = "alarm_b2"
if(0)
icon_state = "alarm_b1"
return
if((stat & (NOPOWER|BROKEN)) || shorted)
icon_state = "alarmp"
return
var/area/A = get_area(src)
switch(max(danger_level, A.atmosalm))
if(0)
icon_state = "alarm0"
if(1)
icon_state = "alarm2" //yes, alarm2 is yellow alarm
if(2)
icon_state = "alarm1"
/obj/machinery/airalarm/process()
if((stat & (NOPOWER|BROKEN)) || shorted)
return
var/turf/location = get_turf(src)
if(!location)
return
var/datum/tlv/cur_tlv
var/datum/gas_mixture/environment = location.return_air()
var/list/env_gases = environment.gases
var/partial_pressure = R_IDEAL_GAS_EQUATION * environment.temperature / environment.volume
cur_tlv = TLV["pressure"]
var/environment_pressure = environment.return_pressure()
var/pressure_dangerlevel = cur_tlv.get_danger_level(environment_pressure)
cur_tlv = TLV["temperature"]
var/temperature_dangerlevel = cur_tlv.get_danger_level(environment.temperature)
var/gas_dangerlevel = 0
for(var/gas_id in env_gases)
if(!(gas_id in TLV)) // We're not interested in this gas, it seems.
continue
cur_tlv = TLV[gas_id]
gas_dangerlevel = max(gas_dangerlevel, cur_tlv.get_danger_level(env_gases[gas_id][MOLES] * partial_pressure))
environment.garbage_collect()
var/old_danger_level = danger_level
danger_level = max(pressure_dangerlevel, temperature_dangerlevel, gas_dangerlevel)
if(old_danger_level != danger_level)
apply_danger_level()
if(mode == AALARM_MODE_REPLACEMENT && environment_pressure < ONE_ATMOSPHERE * 0.05)
mode = AALARM_MODE_SCRUBBING
apply_mode()
/obj/machinery/airalarm/proc/post_alert(alert_level)
var/datum/radio_frequency/frequency = SSradio.return_frequency(alarm_frequency)
if(!frequency)
return
var/area/A = get_area(src)
var/datum/signal/alert_signal = new
alert_signal.source = src
alert_signal.transmission_method = 1
alert_signal.data["zone"] = A.name
alert_signal.data["type"] = "Atmospheric"
if(alert_level==2)
alert_signal.data["alert"] = "severe"
else if (alert_level==1)
alert_signal.data["alert"] = "minor"
else if (alert_level==0)
alert_signal.data["alert"] = "clear"
frequency.post_signal(src, alert_signal,null,-1)
/obj/machinery/airalarm/proc/apply_danger_level()
var/area/A = get_area(src)
var/new_area_danger_level = 0
for(var/area/R in A.related)
for(var/obj/machinery/airalarm/AA in R)
if (!(AA.stat & (NOPOWER|BROKEN)) && !AA.shorted)
new_area_danger_level = max(new_area_danger_level,AA.danger_level)
if(A.atmosalert(new_area_danger_level,src)) //if area was in normal state or if area was in alert state
post_alert(new_area_danger_level)
update_icon()
/obj/machinery/airalarm/attackby(obj/item/W, mob/user, params)
switch(buildstage)
if(2)
if(istype(W, /obj/item/weapon/wirecutters) && panel_open && wires.is_all_cut())
playsound(src.loc, W.usesound, 50, 1)
to_chat(user, "<span class='notice'>You cut the final wires.</span>")
new /obj/item/stack/cable_coil(loc, 5)
buildstage = 1
update_icon()
return
else if(istype(W, /obj/item/weapon/screwdriver)) // Opening that Air Alarm up.
playsound(src.loc, W.usesound, 50, 1)
panel_open = !panel_open
to_chat(user, "<span class='notice'>The wires have been [panel_open ? "exposed" : "unexposed"].</span>")
update_icon()
return
else if(istype(W, /obj/item/weapon/card/id) || istype(W, /obj/item/device/pda))// trying to unlock the interface with an ID card
if(stat & (NOPOWER|BROKEN))
to_chat(user, "<span class='warning'>It does nothing!</span>")
else
if(src.allowed(usr) && !wires.is_cut(WIRE_IDSCAN))
locked = !locked
to_chat(user, "<span class='notice'>You [ locked ? "lock" : "unlock"] the air alarm interface.</span>")
else
to_chat(user, "<span class='danger'>Access denied.</span>")
return
else if(panel_open && is_wire_tool(W))
wires.interact(user)
return
if(1)
if(istype(W, /obj/item/weapon/crowbar))
user.visible_message("[user.name] removes the electronics from [src.name].",\
"<span class='notice'>You start prying out the circuit...</span>")
playsound(src.loc, W.usesound, 50, 1)
if (do_after(user, 20*W.toolspeed, target = src))
if (buildstage == 1)
to_chat(user, "<span class='notice'>You remove the air alarm electronics.</span>")
new /obj/item/weapon/electronics/airalarm( src.loc )
playsound(src.loc, 'sound/items/deconstruct.ogg', 50, 1)
buildstage = 0
update_icon()
return
if(istype(W, /obj/item/stack/cable_coil))
var/obj/item/stack/cable_coil/cable = W
if(cable.get_amount() < 5)
to_chat(user, "<span class='warning'>You need five lengths of cable to wire the fire alarm!</span>")
return
user.visible_message("[user.name] wires the air alarm.", \
"<span class='notice'>You start wiring the air alarm...</span>")
if (do_after(user, 20, target = src))
if (cable.get_amount() >= 5 && buildstage == 1)
cable.use(5)
to_chat(user, "<span class='notice'>You wire the air alarm.</span>")
wires.repair()
aidisabled = 0
locked = TRUE
mode = 1
shorted = 0
post_alert(0)
buildstage = 2
update_icon()
return
if(0)
if(istype(W, /obj/item/weapon/electronics/airalarm))
if(user.temporarilyRemoveItemFromInventory(W))
to_chat(user, "<span class='notice'>You insert the circuit.</span>")
buildstage = 1
update_icon()
qdel(W)
return
if(istype(W, /obj/item/weapon/wrench))
to_chat(user, "<span class='notice'>You detach \the [src] from the wall.</span>")
playsound(src.loc, W.usesound, 50, 1)
new /obj/item/wallframe/airalarm( user.loc )
qdel(src)
return
return ..()
/obj/machinery/airalarm/power_change()
..()
update_icon()
/obj/machinery/airalarm/emag_act(mob/user)
if(emagged)
return
emagged = TRUE
visible_message("<span class='warning'>Sparks fly out of [src]!</span>", "<span class='notice'>You emag [src], disabling its safeties.</span>")
playsound(src, "sparks", 50, 1)
/obj/machinery/airalarm/obj_break(damage_flag)
..()
update_icon()
/obj/machinery/airalarm/deconstruct(disassembled = TRUE)
if(!(flags & NODECONSTRUCT))
new /obj/item/stack/sheet/metal(loc, 2)
var/obj/item/I = new /obj/item/weapon/electronics/airalarm(loc)
if(!disassembled)
I.obj_integrity = I.max_integrity * 0.5
new /obj/item/stack/cable_coil(loc, 3)
qdel(src)
#undef AALARM_MODE_SCRUBBING
#undef AALARM_MODE_VENTING
#undef AALARM_MODE_PANIC
#undef AALARM_MODE_REPLACEMENT
#undef AALARM_MODE_OFF
#undef AALARM_MODE_FLOOD
#undef AALARM_MODE_SIPHON
#undef AALARM_MODE_CONTAMINATED
#undef AALARM_MODE_REFILL
#undef AALARM_REPORT_TIMEOUT