Files
WaterpigandMajkl-J bb70889f6e TG Upstream Part 1
3591 individual conflicts

Update build.js

Update install_node.sh

Update byond.js

oh my fucking god

hat

slow

huh

holy shit

we all fall down

2 more I missed

2900 individual conflicts

2700 Individual conflicts

replaces yarn file with tg version, bumping us down to 2200-ish

Down to 2000 individual conflicts

140 down

mmm

aaaaaaaaaaaaaaaaaaa

not yt

575

soon

900 individual conflicts

600 individual conflicts, 121 file conflicts

im not okay

160 across 19 files

29 in 4 files

0 conflicts, compiletime fix time

some minor incap stuff

missed ticks

weird dupe definition stuff

missed ticks 2

incap fixes

undefs and pie fix

Radio update and some extra minor stuff

returns a single override

no more dupe definitions, 175 compiletime errors

Unticked file fix

sound and emote stuff

honk and more radio stuff
2024-10-19 08:04:33 -07:00

245 lines
8.2 KiB
Plaintext

/// GENERAL AIR CONTROL (a.k.a atmos computer)
/obj/machinery/computer/atmos_control
name = "atmospherics monitoring"
desc = "Used to monitor the station's atmospherics sensors."
icon_screen = "tank"
icon_keyboard = "atmos_key"
circuit = /obj/item/circuitboard/computer/atmos_control
light_color = LIGHT_COLOR_CYAN
/// Which sensors do we want to listen to.
/// Assoc of list[chamber_id] = readable_chamber_name
var/list/atmos_chambers
/// Used when control = FALSE to store the original atmos chambers so they dont get lost when reconnecting
var/list/always_displayed_chambers
/// Whether we can actually adjust the chambers or not.
var/control = TRUE
/// Whether we are allowed to reconnect.
var/reconnecting = TRUE
/// Was this computer multitooled before. If so copy the list connected_sensors as it now maintain's its own sensors independent of the map loaded one's
var/was_multi_tooled = FALSE
/// list of all sensors[key is chamber id, value is id of air sensor linked to this chamber] monitered by this computer
var/list/connected_sensors
/obj/machinery/computer/atmos_control/Initialize(mapload, obj/item/circuitboard/C)
. = ..()
var/static/list/multitool_tips = list(
TOOL_MULTITOOL = list(
SCREENTIP_CONTEXT_LMB = "Link Sensor",
)
)
AddElement(/datum/element/contextual_screentip_tools, multitool_tips)
//all newly constructed/round start computers by default have access to this list
connected_sensors = GLOB.map_loaded_sensors
//special case for the station monitering console. We dont want to loose these chambers during reconnecting
if(!control && !isnull(atmos_chambers))
always_displayed_chambers = atmos_chambers.Copy()
/obj/machinery/computer/atmos_control/examine(mob/user)
. = ..()
. += span_notice("Use a multitool to link a air sensor to this computer")
/// Reconnect only works for station based chambers.
/obj/machinery/computer/atmos_control/proc/reconnect(mob/user)
if(!reconnecting)
return FALSE
// We only prompt the user with the sensors that are actually available.
var/available_devices = list()
for (var/chamber_identifier in connected_sensors)
//this sensor was destroyed at the time of reconnecting
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_identifier]]
if(QDELETED(sensor))
continue
//non master computers don't have access to these station moniters. Only done to give master computer's special access to these chambers and make them feel special or something
if(chamber_identifier == ATMOS_GAS_MONITOR_DISTRO)
continue
if(chamber_identifier == ATMOS_GAS_MONITOR_WASTE)
continue
available_devices[GLOB.station_gas_chambers[chamber_identifier]] = chamber_identifier
// As long as we dont put any funny chars in the strings it should match.
var/new_name = tgui_input_list(user, "Select the device set", "Reconnect", available_devices)
if(isnull(new_name))
return FALSE
var/new_id = available_devices[new_name]
if(isnull(new_id))
return FALSE
atmos_chambers = list()
//these are chambers we always want to display even after reconnecting
if(always_displayed_chambers)
for(var/chamber_id in always_displayed_chambers)
atmos_chambers[chamber_id] = always_displayed_chambers[chamber_id]
atmos_chambers[new_id] = new_name
name = new_name + (control ? " Control" : " Monitor")
return TRUE
/obj/machinery/computer/atmos_control/multitool_act(mob/living/user, obj/item/multitool/multi_tool)
. = ..()
if(istype(multi_tool.buffer, /obj/machinery/air_sensor))
var/obj/machinery/air_sensor/sensor = multi_tool.buffer
//computers reference a global map loaded list of sensor's but as soon a user attempt's to edit it, make a copy of that list so other computers aren't affected
if(!was_multi_tooled)
connected_sensors = connected_sensors.Copy()
was_multi_tooled = TRUE
//register the sensor's unique ID with its assositated chamber
connected_sensors[sensor.chamber_id] = sensor.id_tag
user.balloon_alert(user, "sensor connected to [src]")
return ITEM_INTERACT_SUCCESS
return
/obj/machinery/computer/atmos_control/ui_interact(mob/user, datum/tgui/ui)
. = ..()
ui = SStgui.try_update_ui(user, src, ui)
if(!ui)
ui = new(user, src, "AtmosControlConsole", name)
ui.open()
/obj/machinery/computer/atmos_control/ui_static_data(mob/user)
var/data = list()
data["maxInput"] = MAX_TRANSFER_RATE
data["maxOutput"] = MAX_OUTPUT_PRESSURE
data["control"] = control
data["reconnecting"] = reconnecting
data += return_atmos_handbooks()
return data
/obj/machinery/computer/atmos_control/ui_data(mob/user)
var/data = list()
data["chambers"] = list()
for(var/chamber_id in atmos_chambers)
var/list/chamber_info = list()
chamber_info["id"] = chamber_id
chamber_info["name"] = atmos_chambers[chamber_id]
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_id]]
if(!QDELETED(sensor))
chamber_info["gasmix"] = gas_mixture_parser(sensor.return_air())
if(istype(sensor, /obj/machinery/air_sensor)) //distro & waste loop are not air sensors and don't have these functions
var/obj/machinery/air_sensor/air_sensor = sensor
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[air_sensor.inlet_id || ""]
if (!QDELETED(input))
chamber_info["input_info"] = list(
"active" = input.on,
"amount" = input.volume_rate,
)
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[air_sensor.outlet_id || ""]
if (!QDELETED(output))
chamber_info["output_info"] = list(
"active" = output.on,
"amount" = output.internal_pressure_bound,
)
data["chambers"] += list(chamber_info)
return data
/obj/machinery/computer/atmos_control/ui_act(action, list/params, datum/tgui/ui, datum/ui_state/state)
. = ..()
if(. || !(control || reconnecting))
return
var/chamber = params["chamber"]
switch(action)
if("toggle_input")
if (!(chamber in atmos_chambers))
return TRUE
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
if(QDELETED(sensor))
return TRUE
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
if(QDELETED(input))
return TRUE
input.on = !input.on
input.update_appearance(UPDATE_ICON)
if("toggle_output")
if (!(chamber in atmos_chambers))
return TRUE
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
if(QDELETED(sensor))
return TRUE
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
if(QDELETED(output))
return TRUE
output.on = !output.on
output.update_appearance(UPDATE_ICON)
if("adjust_input")
if (!(chamber in atmos_chambers))
return TRUE
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
if(QDELETED(sensor))
return TRUE
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
if(QDELETED(input))
return TRUE
var/target = text2num(params["rate"])
if(isnull(target))
return TRUE
target = clamp(target, 0, MAX_TRANSFER_RATE)
input.volume_rate = clamp(target, 0, min(input.airs[1].volume, MAX_TRANSFER_RATE))
if("adjust_output")
if (!(chamber in atmos_chambers))
return TRUE
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
if(QDELETED(sensor))
return TRUE
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
if(QDELETED(output))
return TRUE
var/target = text2num(params["rate"])
if(isnull(target))
return TRUE
target = clamp(target, 0, ATMOS_PUMP_MAX_PRESSURE)
output.internal_pressure_bound = target
if("reconnect")
reconnect(usr)
return TRUE
/obj/machinery/computer/atmos_control/nocontrol
control = FALSE
circuit = /obj/item/circuitboard/computer/atmos_control/nocontrol
/obj/machinery/computer/atmos_control/noreconnect
reconnecting = FALSE
circuit = /obj/item/circuitboard/computer/atmos_control/noreconnect
/// Vegetable
/obj/machinery/computer/atmos_control/fixed
control = FALSE
reconnecting = FALSE
circuit = /obj/item/circuitboard/computer/atmos_control/fixed