mirror of
https://github.com/Skyrat-SS13/Skyrat-tg.git
synced 2026-08-31 00:38:34 +01:00
3591 individual conflicts Update build.js Update install_node.sh Update byond.js oh my fucking god hat slow huh holy shit we all fall down 2 more I missed 2900 individual conflicts 2700 Individual conflicts replaces yarn file with tg version, bumping us down to 2200-ish Down to 2000 individual conflicts 140 down mmm aaaaaaaaaaaaaaaaaaa not yt 575 soon 900 individual conflicts 600 individual conflicts, 121 file conflicts im not okay 160 across 19 files 29 in 4 files 0 conflicts, compiletime fix time some minor incap stuff missed ticks weird dupe definition stuff missed ticks 2 incap fixes undefs and pie fix Radio update and some extra minor stuff returns a single override no more dupe definitions, 175 compiletime errors Unticked file fix sound and emote stuff honk and more radio stuff
245 lines
8.2 KiB
Plaintext
245 lines
8.2 KiB
Plaintext
/// GENERAL AIR CONTROL (a.k.a atmos computer)
|
|
/obj/machinery/computer/atmos_control
|
|
name = "atmospherics monitoring"
|
|
desc = "Used to monitor the station's atmospherics sensors."
|
|
icon_screen = "tank"
|
|
icon_keyboard = "atmos_key"
|
|
circuit = /obj/item/circuitboard/computer/atmos_control
|
|
light_color = LIGHT_COLOR_CYAN
|
|
|
|
/// Which sensors do we want to listen to.
|
|
/// Assoc of list[chamber_id] = readable_chamber_name
|
|
var/list/atmos_chambers
|
|
|
|
/// Used when control = FALSE to store the original atmos chambers so they dont get lost when reconnecting
|
|
var/list/always_displayed_chambers
|
|
|
|
/// Whether we can actually adjust the chambers or not.
|
|
var/control = TRUE
|
|
/// Whether we are allowed to reconnect.
|
|
var/reconnecting = TRUE
|
|
|
|
/// Was this computer multitooled before. If so copy the list connected_sensors as it now maintain's its own sensors independent of the map loaded one's
|
|
var/was_multi_tooled = FALSE
|
|
|
|
/// list of all sensors[key is chamber id, value is id of air sensor linked to this chamber] monitered by this computer
|
|
var/list/connected_sensors
|
|
|
|
/obj/machinery/computer/atmos_control/Initialize(mapload, obj/item/circuitboard/C)
|
|
. = ..()
|
|
|
|
var/static/list/multitool_tips = list(
|
|
TOOL_MULTITOOL = list(
|
|
SCREENTIP_CONTEXT_LMB = "Link Sensor",
|
|
)
|
|
)
|
|
AddElement(/datum/element/contextual_screentip_tools, multitool_tips)
|
|
|
|
//all newly constructed/round start computers by default have access to this list
|
|
connected_sensors = GLOB.map_loaded_sensors
|
|
|
|
//special case for the station monitering console. We dont want to loose these chambers during reconnecting
|
|
if(!control && !isnull(atmos_chambers))
|
|
always_displayed_chambers = atmos_chambers.Copy()
|
|
|
|
/obj/machinery/computer/atmos_control/examine(mob/user)
|
|
. = ..()
|
|
. += span_notice("Use a multitool to link a air sensor to this computer")
|
|
|
|
/// Reconnect only works for station based chambers.
|
|
/obj/machinery/computer/atmos_control/proc/reconnect(mob/user)
|
|
if(!reconnecting)
|
|
return FALSE
|
|
|
|
// We only prompt the user with the sensors that are actually available.
|
|
var/available_devices = list()
|
|
|
|
for (var/chamber_identifier in connected_sensors)
|
|
//this sensor was destroyed at the time of reconnecting
|
|
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_identifier]]
|
|
if(QDELETED(sensor))
|
|
continue
|
|
|
|
//non master computers don't have access to these station moniters. Only done to give master computer's special access to these chambers and make them feel special or something
|
|
if(chamber_identifier == ATMOS_GAS_MONITOR_DISTRO)
|
|
continue
|
|
if(chamber_identifier == ATMOS_GAS_MONITOR_WASTE)
|
|
continue
|
|
|
|
available_devices[GLOB.station_gas_chambers[chamber_identifier]] = chamber_identifier
|
|
|
|
// As long as we dont put any funny chars in the strings it should match.
|
|
var/new_name = tgui_input_list(user, "Select the device set", "Reconnect", available_devices)
|
|
if(isnull(new_name))
|
|
return FALSE
|
|
var/new_id = available_devices[new_name]
|
|
if(isnull(new_id))
|
|
return FALSE
|
|
|
|
atmos_chambers = list()
|
|
//these are chambers we always want to display even after reconnecting
|
|
if(always_displayed_chambers)
|
|
for(var/chamber_id in always_displayed_chambers)
|
|
atmos_chambers[chamber_id] = always_displayed_chambers[chamber_id]
|
|
atmos_chambers[new_id] = new_name
|
|
|
|
name = new_name + (control ? " Control" : " Monitor")
|
|
|
|
return TRUE
|
|
|
|
/obj/machinery/computer/atmos_control/multitool_act(mob/living/user, obj/item/multitool/multi_tool)
|
|
. = ..()
|
|
|
|
if(istype(multi_tool.buffer, /obj/machinery/air_sensor))
|
|
var/obj/machinery/air_sensor/sensor = multi_tool.buffer
|
|
//computers reference a global map loaded list of sensor's but as soon a user attempt's to edit it, make a copy of that list so other computers aren't affected
|
|
if(!was_multi_tooled)
|
|
connected_sensors = connected_sensors.Copy()
|
|
was_multi_tooled = TRUE
|
|
//register the sensor's unique ID with its assositated chamber
|
|
connected_sensors[sensor.chamber_id] = sensor.id_tag
|
|
user.balloon_alert(user, "sensor connected to [src]")
|
|
return ITEM_INTERACT_SUCCESS
|
|
|
|
return
|
|
|
|
/obj/machinery/computer/atmos_control/ui_interact(mob/user, datum/tgui/ui)
|
|
. = ..()
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "AtmosControlConsole", name)
|
|
ui.open()
|
|
|
|
/obj/machinery/computer/atmos_control/ui_static_data(mob/user)
|
|
var/data = list()
|
|
data["maxInput"] = MAX_TRANSFER_RATE
|
|
data["maxOutput"] = MAX_OUTPUT_PRESSURE
|
|
data["control"] = control
|
|
data["reconnecting"] = reconnecting
|
|
data += return_atmos_handbooks()
|
|
return data
|
|
|
|
/obj/machinery/computer/atmos_control/ui_data(mob/user)
|
|
var/data = list()
|
|
|
|
data["chambers"] = list()
|
|
for(var/chamber_id in atmos_chambers)
|
|
var/list/chamber_info = list()
|
|
chamber_info["id"] = chamber_id
|
|
chamber_info["name"] = atmos_chambers[chamber_id]
|
|
|
|
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_id]]
|
|
if(!QDELETED(sensor))
|
|
chamber_info["gasmix"] = gas_mixture_parser(sensor.return_air())
|
|
|
|
if(istype(sensor, /obj/machinery/air_sensor)) //distro & waste loop are not air sensors and don't have these functions
|
|
var/obj/machinery/air_sensor/air_sensor = sensor
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[air_sensor.inlet_id || ""]
|
|
if (!QDELETED(input))
|
|
chamber_info["input_info"] = list(
|
|
"active" = input.on,
|
|
"amount" = input.volume_rate,
|
|
)
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[air_sensor.outlet_id || ""]
|
|
if (!QDELETED(output))
|
|
chamber_info["output_info"] = list(
|
|
"active" = output.on,
|
|
"amount" = output.internal_pressure_bound,
|
|
)
|
|
|
|
data["chambers"] += list(chamber_info)
|
|
return data
|
|
|
|
/obj/machinery/computer/atmos_control/ui_act(action, list/params, datum/tgui/ui, datum/ui_state/state)
|
|
. = ..()
|
|
if(. || !(control || reconnecting))
|
|
return
|
|
|
|
var/chamber = params["chamber"]
|
|
|
|
switch(action)
|
|
if("toggle_input")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
|
|
if(QDELETED(input))
|
|
return TRUE
|
|
|
|
input.on = !input.on
|
|
input.update_appearance(UPDATE_ICON)
|
|
if("toggle_output")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
|
|
if(QDELETED(output))
|
|
return TRUE
|
|
|
|
output.on = !output.on
|
|
output.update_appearance(UPDATE_ICON)
|
|
if("adjust_input")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
|
|
if(QDELETED(input))
|
|
return TRUE
|
|
|
|
var/target = text2num(params["rate"])
|
|
if(isnull(target))
|
|
return TRUE
|
|
target = clamp(target, 0, MAX_TRANSFER_RATE)
|
|
|
|
input.volume_rate = clamp(target, 0, min(input.airs[1].volume, MAX_TRANSFER_RATE))
|
|
if("adjust_output")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
|
|
if(QDELETED(output))
|
|
return TRUE
|
|
|
|
var/target = text2num(params["rate"])
|
|
if(isnull(target))
|
|
return TRUE
|
|
target = clamp(target, 0, ATMOS_PUMP_MAX_PRESSURE)
|
|
|
|
output.internal_pressure_bound = target
|
|
if("reconnect")
|
|
reconnect(usr)
|
|
|
|
return TRUE
|
|
|
|
/obj/machinery/computer/atmos_control/nocontrol
|
|
control = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/nocontrol
|
|
|
|
/obj/machinery/computer/atmos_control/noreconnect
|
|
reconnecting = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/noreconnect
|
|
|
|
/// Vegetable
|
|
/obj/machinery/computer/atmos_control/fixed
|
|
control = FALSE
|
|
reconnecting = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/fixed
|