## About The Pull Request Implements half of this (with some minor changes):  The ultimate goal of this is to split our attack chain in two: - One for non-combat item interactions - Health analyzer scanning - using tools on stuff - surgery - Niche other interactions - One for combat attacking - Item hit thing, item deal damage. - Special effects on attack would go here. This PR begins this by broadining tool act into item interact. Item interact is a catch-all proc ran at the beginning of attack chain, before `pre_attack` and such, that handles the first part of the chain. This allows us to easily catch item interaction and cancel the attack part of the chain by using deliberate bitflag return values, rather than `TRUE` / `FALSE`*. *Because right now, `TRUE` = `cancel attack`, no matter what, which is unclear to people. Instead of moving as much as possible to the new proc in this PR, I started by doing some easy, obvious things. More things can be moved in the future, or technically they don't even need to move in a lot of cases. ## Changelog 🆑 Melbert refactor: Refactored some methods of items interacting with other objects or mobs, such as surgery and health analzyers. Report if anything seems wrong /🆑
245 lines
8.2 KiB
Plaintext
245 lines
8.2 KiB
Plaintext
/// GENERAL AIR CONTROL (a.k.a atmos computer)
|
|
/obj/machinery/computer/atmos_control
|
|
name = "atmospherics monitoring"
|
|
desc = "Used to monitor the station's atmospherics sensors."
|
|
icon_screen = "tank"
|
|
icon_keyboard = "atmos_key"
|
|
circuit = /obj/item/circuitboard/computer/atmos_control
|
|
light_color = LIGHT_COLOR_CYAN
|
|
|
|
/// Which sensors do we want to listen to.
|
|
/// Assoc of list[chamber_id] = readable_chamber_name
|
|
var/list/atmos_chambers
|
|
|
|
/// Used when control = FALSE to store the original atmos chambers so they dont get lost when reconnecting
|
|
var/list/always_displayed_chambers
|
|
|
|
/// Whether we can actually adjust the chambers or not.
|
|
var/control = TRUE
|
|
/// Whether we are allowed to reconnect.
|
|
var/reconnecting = TRUE
|
|
|
|
/// Was this computer multitooled before. If so copy the list connected_sensors as it now mantain's it's own sensors independent of the map loaded one's
|
|
var/was_multi_tooled = FALSE
|
|
|
|
/// list of all sensors[key is chamber id, value is id of air sensor linked to this chamber] monitered by this computer
|
|
var/list/connected_sensors
|
|
|
|
/obj/machinery/computer/atmos_control/Initialize(mapload, obj/item/circuitboard/C)
|
|
. = ..()
|
|
|
|
var/static/list/multitool_tips = list(
|
|
TOOL_MULTITOOL = list(
|
|
SCREENTIP_CONTEXT_LMB = "Link Sensor",
|
|
)
|
|
)
|
|
AddElement(/datum/element/contextual_screentip_tools, multitool_tips)
|
|
|
|
//all newly constructed/round start computers by default have access to this list
|
|
connected_sensors = GLOB.map_loaded_sensors
|
|
|
|
//special case for the station monitering console. We dont want to loose these chambers during reconnecting
|
|
if(!control && !isnull(atmos_chambers))
|
|
always_displayed_chambers = atmos_chambers.Copy()
|
|
|
|
/obj/machinery/computer/atmos_control/examine(mob/user)
|
|
. = ..()
|
|
. += span_notice("Use a multitool to link a air sensor to this computer")
|
|
|
|
/// Reconnect only works for station based chambers.
|
|
/obj/machinery/computer/atmos_control/proc/reconnect(mob/user)
|
|
if(!reconnecting)
|
|
return FALSE
|
|
|
|
// We only prompt the user with the sensors that are actually available.
|
|
var/available_devices = list()
|
|
|
|
for (var/chamber_identifier in connected_sensors)
|
|
//this sensor was destroyed at the time of reconnecting
|
|
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_identifier]]
|
|
if(QDELETED(sensor))
|
|
continue
|
|
|
|
//non master computers don't have access to these station moniters. Only done to give master computer's special access to these chambers and make them feel special or something
|
|
if(chamber_identifier == ATMOS_GAS_MONITOR_DISTRO)
|
|
continue
|
|
if(chamber_identifier == ATMOS_GAS_MONITOR_WASTE)
|
|
continue
|
|
|
|
available_devices[GLOB.station_gas_chambers[chamber_identifier]] = chamber_identifier
|
|
|
|
// As long as we dont put any funny chars in the strings it should match.
|
|
var/new_name = tgui_input_list(user, "Select the device set", "Reconnect", available_devices)
|
|
if(isnull(new_name))
|
|
return FALSE
|
|
var/new_id = available_devices[new_name]
|
|
if(isnull(new_id))
|
|
return FALSE
|
|
|
|
atmos_chambers = list()
|
|
//these are chambers we always want to display even after reconnecting
|
|
if(always_displayed_chambers)
|
|
for(var/chamber_id in always_displayed_chambers)
|
|
atmos_chambers[chamber_id] = always_displayed_chambers[chamber_id]
|
|
atmos_chambers[new_id] = new_name
|
|
|
|
name = new_name + (control ? " Control" : " Monitor")
|
|
|
|
return TRUE
|
|
|
|
/obj/machinery/computer/atmos_control/multitool_act(mob/living/user, obj/item/multitool/multi_tool)
|
|
. = ..()
|
|
|
|
if(istype(multi_tool.buffer, /obj/machinery/air_sensor))
|
|
var/obj/machinery/air_sensor/sensor = multi_tool.buffer
|
|
//computers reference a global map loaded list of sensor's but as soon a user attempt's to edit it, make a copy of that list so other computers aren't affected
|
|
if(!was_multi_tooled)
|
|
connected_sensors = connected_sensors.Copy()
|
|
was_multi_tooled = TRUE
|
|
//register the sensor's unique ID with it's assositated chamber
|
|
connected_sensors[sensor.chamber_id] = sensor.id_tag
|
|
user.balloon_alert(user, "sensor connected to [src]")
|
|
return ITEM_INTERACT_SUCCESS
|
|
|
|
return
|
|
|
|
/obj/machinery/computer/atmos_control/ui_interact(mob/user, datum/tgui/ui)
|
|
. = ..()
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "AtmosControlConsole", name)
|
|
ui.open()
|
|
|
|
/obj/machinery/computer/atmos_control/ui_static_data(mob/user)
|
|
var/data = list()
|
|
data["maxInput"] = MAX_TRANSFER_RATE
|
|
data["maxOutput"] = MAX_OUTPUT_PRESSURE
|
|
data["control"] = control
|
|
data["reconnecting"] = reconnecting
|
|
data += return_atmos_handbooks()
|
|
return data
|
|
|
|
/obj/machinery/computer/atmos_control/ui_data(mob/user)
|
|
var/data = list()
|
|
|
|
data["chambers"] = list()
|
|
for(var/chamber_id in atmos_chambers)
|
|
var/list/chamber_info = list()
|
|
chamber_info["id"] = chamber_id
|
|
chamber_info["name"] = atmos_chambers[chamber_id]
|
|
|
|
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_id]]
|
|
if(!QDELETED(sensor))
|
|
chamber_info["gasmix"] = gas_mixture_parser(sensor.return_air())
|
|
|
|
if(istype(sensor, /obj/machinery/air_sensor)) //distro & waste loop are not air sensors and don't have these functions
|
|
var/obj/machinery/air_sensor/air_sensor = sensor
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[air_sensor.inlet_id || ""]
|
|
if (!QDELETED(input))
|
|
chamber_info["input_info"] = list(
|
|
"active" = input.on,
|
|
"amount" = input.volume_rate,
|
|
)
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[air_sensor.outlet_id || ""]
|
|
if (!QDELETED(output))
|
|
chamber_info["output_info"] = list(
|
|
"active" = output.on,
|
|
"amount" = output.internal_pressure_bound,
|
|
)
|
|
|
|
data["chambers"] += list(chamber_info)
|
|
return data
|
|
|
|
/obj/machinery/computer/atmos_control/ui_act(action, params)
|
|
. = ..()
|
|
if(. || !(control || reconnecting))
|
|
return
|
|
|
|
var/chamber = params["chamber"]
|
|
|
|
switch(action)
|
|
if("toggle_input")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
|
|
if(QDELETED(input))
|
|
return TRUE
|
|
|
|
input.on = !input.on
|
|
input.update_appearance(UPDATE_ICON)
|
|
if("toggle_output")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
|
|
if(QDELETED(output))
|
|
return TRUE
|
|
|
|
output.on = !output.on
|
|
output.update_appearance(UPDATE_ICON)
|
|
if("adjust_input")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
|
|
if(QDELETED(input))
|
|
return TRUE
|
|
|
|
var/target = text2num(params["rate"])
|
|
if(isnull(target))
|
|
return TRUE
|
|
target = clamp(target, 0, MAX_TRANSFER_RATE)
|
|
|
|
input.volume_rate = clamp(target, 0, min(input.airs[1].volume, MAX_TRANSFER_RATE))
|
|
if("adjust_output")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
|
|
if(QDELETED(output))
|
|
return TRUE
|
|
|
|
var/target = text2num(params["rate"])
|
|
if(isnull(target))
|
|
return TRUE
|
|
target = clamp(target, 0, ATMOS_PUMP_MAX_PRESSURE)
|
|
|
|
output.internal_pressure_bound = target
|
|
if("reconnect")
|
|
reconnect(usr)
|
|
|
|
return TRUE
|
|
|
|
/obj/machinery/computer/atmos_control/nocontrol
|
|
control = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/nocontrol
|
|
|
|
/obj/machinery/computer/atmos_control/noreconnect
|
|
reconnecting = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/noreconnect
|
|
|
|
/// Vegetable
|
|
/obj/machinery/computer/atmos_control/fixed
|
|
control = FALSE
|
|
reconnecting = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/fixed
|