From 080b0178ab21522b05c576cb5a5c0118f6e03d74 Mon Sep 17 00:00:00 2001 From: PsiOmega Date: Fri, 10 Apr 2015 15:19:55 +0200 Subject: [PATCH] Fixes issue with the alarm monitor (only sometimes) listing a null missing alarm source. --- code/modules/nano/modules/alarm_monitor.dm | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/code/modules/nano/modules/alarm_monitor.dm b/code/modules/nano/modules/alarm_monitor.dm index 9047023bf1b..b27349bf9a8 100644 --- a/code/modules/nano/modules/alarm_monitor.dm +++ b/code/modules/nano/modules/alarm_monitor.dm @@ -85,7 +85,7 @@ "origin_lost" = A.origin == null, "has_cameras" = cameras.len, "cameras" = cameras, - "lost_sources" = sanitize(english_list(lost_sources, nothing_text = "", and_text = ", ")))) + "lost_sources" = lost_sources.len ? sanitize(english_list(lost_sources, nothing_text = "", and_text = ", ")) : "")) data["categories"] = categories ui = nanomanager.try_update_ui(user, src, ui_key, ui, data, force_open)