Revert "[MIRROR] /atom New() => Initialize() [MDB IGNORE]"

This commit is contained in:
Novacat
2022-08-27 08:49:56 -04:00
committed by GitHub
parent 0be7af4774
commit 1aa4c73e8d
599 changed files with 3329 additions and 4983 deletions
@@ -9,8 +9,8 @@
var/datum/pipe_network/network1
var/datum/pipe_network/network2
/obj/machinery/atmospherics/binary/Initialize()
. = ..()
/obj/machinery/atmospherics/binary/New()
..()
air1 = new
air2 = new
@@ -24,8 +24,8 @@
density = TRUE
/obj/machinery/atmospherics/binary/circulator/Initialize()
. = ..()
/obj/machinery/atmospherics/binary/circulator/New()
..()
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
air1.volume = 400
@@ -42,10 +42,8 @@
//2: Do not pass input_pressure_min
//4: Do not pass output_pressure_max
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
icon = null
@@ -57,8 +55,8 @@
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
name = "Large Dual Port Air Vent"
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/Initialize()
. = ..()
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
@@ -196,6 +194,11 @@
return 1
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/dp_vent_pump/examine(mob/user)
. = ..()
if(Adjacent(user))
@@ -27,12 +27,10 @@
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/passive_gate/Initialize()
. = ..()
/obj/machinery/atmospherics/binary/passive_gate/New()
..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/Destroy()
unregister_radio(src, frequency)
@@ -168,8 +166,14 @@
)
radio_connection.post_signal(src, signal, radio_filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/passive_gate/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
@@ -37,12 +37,10 @@ Thus, the two variables affect pump operation are set in New():
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/pump/Initialize()
. = ..()
/obj/machinery/atmospherics/binary/pump/New()
..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/pump/Destroy()
unregister_radio(src, frequency)
@@ -168,6 +166,11 @@ Thus, the two variables affect pump operation are set in New():
return data
/obj/machinery/atmospherics/binary/pump/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
@@ -20,8 +20,8 @@
var/list/filtering_outputs = list() //maps gasids to gas_mixtures
/obj/machinery/atmospherics/omni/atmos_filter/Initialize()
. = ..()
/obj/machinery/atmospherics/omni/atmos_filter/New()
..()
rebuild_filtering_list()
for(var/datum/omni_port/P in ports)
P.air.volume = ATMOS_DEFAULT_VOLUME_FILTER
@@ -24,8 +24,8 @@
var/list/mixing_inputs = list()
/obj/machinery/atmospherics/omni/mixer/Initialize()
. = ..()
/obj/machinery/atmospherics/omni/mixer/New()
..()
if(mapper_set())
var/con = 0
for(var/datum/omni_port/P in ports)
@@ -25,8 +25,8 @@
var/list/ports = new()
/obj/machinery/atmospherics/omni/Initialize()
. = ..()
/obj/machinery/atmospherics/omni/New()
..()
icon_state = "base"
ports = new()
@@ -39,8 +39,8 @@
if(frequency)
radio_connection = radio_controller.add_object(src, frequency, RADIO_ATMOSIA)
/obj/machinery/atmospherics/trinary/atmos_filter/Initialize()
. = ..()
/obj/machinery/atmospherics/trinary/atmos_filter/New()
..()
switch(filter_type)
if(0) //removing hydrocarbons
filtered_out = list("phoron")
@@ -56,8 +56,6 @@
air1.volume = ATMOS_DEFAULT_VOLUME_FILTER
air2.volume = ATMOS_DEFAULT_VOLUME_FILTER
air3.volume = ATMOS_DEFAULT_VOLUME_FILTER
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/trinary/atmos_filter/Destroy()
unregister_radio(src, frequency)
@@ -108,6 +106,11 @@
return 1
/obj/machinery/atmospherics/trinary/atmos_filter/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/trinary/atmos_filter/attack_hand(user) // -- TLE
if(..())
return
@@ -37,8 +37,8 @@
icon_state += "off"
update_use_power(USE_POWER_OFF)
/obj/machinery/atmospherics/trinary/mixer/Initialize()
. = ..()
/obj/machinery/atmospherics/trinary/mixer/New()
..()
air1.volume = ATMOS_DEFAULT_VOLUME_MIXER
air2.volume = ATMOS_DEFAULT_VOLUME_MIXER
air3.volume = ATMOS_DEFAULT_VOLUME_MIXER * 1.5
@@ -17,8 +17,8 @@
var/datum/pipe_network/network2
var/datum/pipe_network/network3
/obj/machinery/atmospherics/trinary/Initialize()
. = ..()
/obj/machinery/atmospherics/trinary/New()
..()
air1 = new
air2 = new
@@ -24,11 +24,9 @@
level = 1
/obj/machinery/atmospherics/unary/outlet_injector/Initialize()
. = ..()
/obj/machinery/atmospherics/unary/outlet_injector/New()
..()
air_contents.volume = ATMOS_DEFAULT_VOLUME_PUMP + 500 //Give it a small reservoir for injecting. Also allows it to have a higher flow rate limit than vent pumps, to differentiate injectors a bit more.
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/unary/outlet_injector/Destroy()
unregister_radio(src, frequency)
@@ -124,6 +122,11 @@
return 1
/obj/machinery/atmospherics/unary/outlet_injector/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/unary/outlet_injector/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
@@ -13,8 +13,8 @@
var/welded = 0 //defining this here for ventcrawl stuff
/obj/machinery/atmospherics/unary/Initialize()
. = ..()
/obj/machinery/atmospherics/unary/New()
..()
air_contents = new
air_contents.volume = 200
@@ -83,6 +83,8 @@
. = ..()
//soundloop = new(list(src), FALSE)
/obj/machinery/atmospherics/unary/vent_pump/New()
..()
air_contents.volume = ATMOS_DEFAULT_VOLUME_PUMP
icon = null
@@ -110,8 +112,8 @@
icon_connect_type = "-aux"
connect_types = CONNECT_TYPE_AUX //connects to aux pipes
/obj/machinery/atmospherics/unary/vent_pump/high_volume/Initialize()
. = ..()
/obj/machinery/atmospherics/unary/vent_pump/high_volume/New()
..()
air_contents.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
// VOREStation Edit Start - Wall mounted vents
@@ -135,8 +137,8 @@
power_channel = ENVIRON
power_rating = 30000 //15 kW ~ 20 HP
/obj/machinery/atmospherics/unary/vent_pump/engine/Initialize()
. = ..()
/obj/machinery/atmospherics/unary/vent_pump/engine/New()
..()
air_contents.volume = ATMOS_DEFAULT_VOLUME_PUMP + 500 //meant to match air injector
/obj/machinery/atmospherics/unary/vent_pump/update_icon(var/safety = 0)
@@ -32,8 +32,8 @@
use_power = USE_POWER_IDLE
icon_state = "map_scrubber_on"
/obj/machinery/atmospherics/unary/vent_scrubber/Initialize()
. = ..()
/obj/machinery/atmospherics/unary/vent_scrubber/New()
..()
air_contents.volume = ATMOS_DEFAULT_VOLUME_FILTER
icon = null