@@ -1,8 +1,5 @@
//node1, air1, network1 correspond to input
//node2, air2, network2 correspond to output
#define ADIABATIC_EXPONENT 0.667 //Actually adiabatic exponent - 1.
/obj/machinery/atmospherics/binary/circulator
name = "circulator"
desc = "A gas circulator turbine and heat exchanger."
@@ -163,7 +163,7 @@
//
// "T" Orientation - Inputs are on oposite sides instead of adjacent
//
obj/machinery/atmospherics/trinary/mixer/t_mixer
/obj/machinery/atmospherics/trinary/mixer/t_mixer
icon_state = "tmap"
construction_type = /obj/item/pipe/trinary // Can't flip a "T", its symmetrical
pipe_state = "t_mixer"
@@ -1,21 +0,0 @@
/obj/machinery/atmospherics/unary/generator_input
icon = 'icons/obj/atmospherics/heat_exchanger.dmi'
icon_state = "intact"
density = 1
name = "Generator Input"
desc = "Placeholder"
var/update_cycle
update_icon()
if(node)
icon_state = "intact"
else
icon_state = "exposed"
return
proc
return_exchange_air()
return air_contents
@@ -11,77 +11,77 @@
var/obj/machinery/atmospherics/unary/heat_exchanger/partner = null
var/update_cycle
update_icon()
if(node)
icon_state = "intact"
else
icon_state = "exposed"
/obj/machinery/atmospherics/unary/heat_exchanger/update_icon()
if(node)
icon_state = "intact"
else
icon_state = "exposed"
return
return
atmos_init()
if(!partner)
var/partner_connect = turn(dir,180)
/obj/machinery/atmospherics/unary/heat_exchanger/atmos_init()
if(!partner)
var/partner_connect = turn(dir,180)
for(var/obj/machinery/atmospherics/unary/heat_exchanger/target in get_step(src,partner_connect))
if(target.dir & get_dir(src,target))
partner = target
partner.partner = src
break
for(var/obj/machinery/atmospherics/unary/heat_exchanger/target in get_step(src,partner_connect))
if(target.dir & get_dir(src,target))
partner = target
partner.partner = src
break
..()
..()
process()
..()
if(!partner)
return 0
/obj/machinery/atmospherics/unary/heat_exchanger/process()
..()
if(!partner)
return 0
if(!air_master || air_master.current_cycle <= update_cycle)
return 0
if(!air_master || air_master.current_cycle <= update_cycle)
return 0
update_cycle = air_master.current_cycle
partner.update_cycle = air_master.current_cycle
update_cycle = air_master.current_cycle
partner.update_cycle = air_master.current_cycle
var/air_heat_capacity = air_contents.heat_capacity()
var/other_air_heat_capacity = partner.air_contents.heat_capacity()
var/combined_heat_capacity = other_air_heat_capacity + air_heat_capacity
var/air_heat_capacity = air_contents.heat_capacity()
var/other_air_heat_capacity = partner.air_contents.heat_capacity()
var/combined_heat_capacity = other_air_heat_capacity + air_heat_capacity
var/old_temperature = air_contents.temperature
var/other_old_temperature = partner.air_contents.temperature
var/old_temperature = air_contents.temperature
var/other_old_temperature = partner.air_contents.temperature
if(combined_heat_capacity > 0)
var/combined_energy = partner.air_contents.temperature*other_air_heat_capacity + air_heat_capacity*air_contents.temperature
if(combined_heat_capacity > 0)
var/combined_energy = partner.air_contents.temperature*other_air_heat_capacity + air_heat_capacity*air_contents.temperature
var/new_temperature = combined_energy/combined_heat_capacity
air_contents.temperature = new_temperature
partner.air_contents.temperature = new_temperature
var/new_temperature = combined_energy/combined_heat_capacity
air_contents.temperature = new_temperature
partner.air_contents.temperature = new_temperature
if(network)
if(abs(old_temperature-air_contents.temperature) > 1)
network.update = 1
if(network)
if(abs(old_temperature-air_contents.temperature) > 1)
network.update = 1
if(partner.network)
if(abs(other_old_temperature-partner.air_contents.temperature) > 1)
partner.network.update = 1
if(partner.network)
if(abs(other_old_temperature-partner.air_contents.temperature) > 1)
partner.network.update = 1
return 1
/obj/machinery/atmospherics/unary/heat_exchanger/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob)
if (!W.is_wrench())
return ..()
var/turf/T = src.loc
if (level==1 && isturf(T) && !T.is_plating())
to_chat(user, "<span class='warning'>You must remove the plating first.</span>")
return 1
attackby(var/obj/item/weapon/W as obj, var/mob/user as mob)
if (!W.is_wrench())
return ..()
var/turf/T = src.loc
if (level==1 && isturf(T) && !T.is_plating())
to_chat(user, "<span class='warning'>You must remove the plating first.</span>")
return 1
if (!can_unwrench())
to_chat(user, "<span class='warning'>You cannot unwrench \the [src], it is too exerted due to internal pressure.</span>")
add_fingerprint(user)
return 1
playsound(src, W.usesound, 50, 1)
to_chat(user, "<span class='notice'>You begin to unfasten \the [src]...</span>")
if (do_after(user, 40 * W.toolspeed))
user.visible_message( \
"<span class='notice'>\The [user] unfastens \the [src].</span>", \
"<span class='notice'>You have unfastened \the [src].</span>", \
"You hear a ratchet.")
deconstruct()
if (!can_unwrench())
to_chat(user, "<span class='warning'>You cannot unwrench \the [src], it is too exerted due to internal pressure.</span>")
add_fingerprint(user)
return 1
playsound(src, W.usesound, 50, 1)
to_chat(user, "<span class='notice'>You begin to unfasten \the [src]...</span>")
if (do_after(user, 40 * W.toolspeed))
user.visible_message( \
"<span class='notice'>\The [user] unfastens \the [src].</span>", \
"<span class='notice'>You have unfastened \the [src].</span>", \
"You hear a ratchet.")
deconstruct()
@@ -1,49 +0,0 @@
obj/machinery/atmospherics/unary/oxygen_generator
icon = 'icons/obj/atmospherics/oxygen_generator.dmi'
icon_state = "intact_off"
density = 1
name = "Oxygen Generator"
desc = ""
dir = SOUTH
initialize_directions = SOUTH
var/on = 0
var/oxygen_content = 10
update_icon()
if(node)
icon_state = "intact_[on?("on"):("off")]"
else
icon_state = "exposed_off"
on = 0
return
New()
..()
air_contents.volume = 50
process()
..()
if(!on)
return 0
var/total_moles = air_contents.total_moles
if(total_moles < oxygen_content)
var/current_heat_capacity = air_contents.heat_capacity()
var/added_oxygen = oxygen_content - total_moles
air_contents.temperature = (current_heat_capacity*air_contents.temperature + 20*added_oxygen*T0C)/(current_heat_capacity+20*added_oxygen)
air_contents.adjust_gas("oxygen", added_oxygen)
if(network)
network.update = 1
return 1