mirror of
https://github.com/VOREStation/VOREStation.git
synced 2026-08-22 19:47:47 +01:00
Whitespace Standardization [MDB IGNORE] (#15748)
* Update settings * Whitespace changes * Comment out merger hooks in gitattributes Corrupt maps would have to be resolved in repo before hooks could be updated * Revert "Whitespace changes" This reverts commitafbdd1d844. * Whitespace again minus example * Gitignore example changelog * Restore changelog merge setting * Keep older dmi hook attribute until hooks can be updated * update vscode settings too * Renormalize remaining * Revert "Gitignore example changelog" This reverts commitde22ad375d. * Attempt to normalize example.yml (and another file I guess) * Try again
This commit is contained in:
@@ -1,263 +1,263 @@
|
||||
#define DEFAULT_PRESSURE_DELTA 10000
|
||||
|
||||
#define EXTERNAL_PRESSURE_BOUND ONE_ATMOSPHERE
|
||||
#define INTERNAL_PRESSURE_BOUND 0
|
||||
#define PRESSURE_CHECKS 1
|
||||
|
||||
#define PRESSURE_CHECK_EXTERNAL 1
|
||||
#define PRESSURE_CHECK_INPUT 2
|
||||
#define PRESSURE_CHECK_OUTPUT 4
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump
|
||||
icon = 'icons/atmos/vent_pump.dmi'
|
||||
icon_state = "map_dp_vent"
|
||||
|
||||
//node2 is output port
|
||||
//node1 is input port
|
||||
|
||||
name = "Dual Port Air Vent"
|
||||
desc = "Has a valve and pump attached to it. There are two ports."
|
||||
|
||||
level = 1
|
||||
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
pipe_flags = PIPING_ALL_LAYER
|
||||
connect_types = CONNECT_TYPE_REGULAR|CONNECT_TYPE_SUPPLY|CONNECT_TYPE_SCRUBBER //connects to regular, supply and scrubbers pipes
|
||||
|
||||
var/pump_direction = 1 //0 = siphoning, 1 = releasing
|
||||
|
||||
var/external_pressure_bound = EXTERNAL_PRESSURE_BOUND
|
||||
var/input_pressure_min = INTERNAL_PRESSURE_BOUND
|
||||
var/output_pressure_max = DEFAULT_PRESSURE_DELTA
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
var/pressure_checks = PRESSURE_CHECK_EXTERNAL
|
||||
//1: Do not pass external_pressure_bound
|
||||
//2: Do not pass input_pressure_min
|
||||
//4: Do not pass output_pressure_max
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
|
||||
..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
icon = null
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Destroy()
|
||||
unregister_radio(src, frequency)
|
||||
. = ..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
|
||||
name = "Large Dual Port Air Vent"
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
|
||||
..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
|
||||
if(!check_icon_cache())
|
||||
return
|
||||
|
||||
cut_overlays()
|
||||
|
||||
var/vent_icon = "vent"
|
||||
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
vent_icon += "h"
|
||||
|
||||
if(!powered())
|
||||
vent_icon += "off"
|
||||
else
|
||||
vent_icon += "[use_power ? "[pump_direction ? "out" : "in"]" : "off"]"
|
||||
|
||||
add_overlay(icon_manager.get_atmos_icon("device", , , vent_icon))
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
return
|
||||
else
|
||||
if (node1)
|
||||
add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
if (node2)
|
||||
add_underlay(T, node2, dir, node2.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/hide(var/i)
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/process()
|
||||
..()
|
||||
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
|
||||
if(stat & (NOPOWER|BROKEN) || !use_power)
|
||||
return 0
|
||||
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
|
||||
var/power_draw = -1
|
||||
|
||||
//Figure out the target pressure difference
|
||||
var/pressure_delta = get_pressure_delta(environment)
|
||||
|
||||
if(pressure_delta > 0.5)
|
||||
if(pump_direction) //internal -> external
|
||||
if (node1 && (environment.temperature || air1.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(air1, environment, pressure_delta)
|
||||
power_draw = pump_gas(src, air1, environment, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network1)
|
||||
network1.update = 1
|
||||
else //external -> internal
|
||||
if (node2 && (environment.temperature || air2.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(environment, air2, pressure_delta, (network2)? network2.volume : 0)
|
||||
|
||||
//limit flow rate from turfs
|
||||
transfer_moles = min(transfer_moles, environment.total_moles*air2.volume/environment.volume) //group_multiplier gets divided out here
|
||||
power_draw = pump_gas(src, environment, air2, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network2)
|
||||
network2.update = 1
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/get_pressure_delta(datum/gas_mixture/environment)
|
||||
var/pressure_delta = DEFAULT_PRESSURE_DELTA
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
|
||||
if(pump_direction) //internal -> external
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, external_pressure_bound - environment_pressure) //increasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_INPUT)
|
||||
pressure_delta = min(pressure_delta, air1.return_pressure() - input_pressure_min) //decreasing the pressure here
|
||||
else //external -> internal
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, environment_pressure - external_pressure_bound) //decreasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_OUTPUT)
|
||||
pressure_delta = min(pressure_delta, output_pressure_max - air2.return_pressure()) //increasing the pressure here
|
||||
|
||||
return pressure_delta
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency)
|
||||
radio_controller.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = radio_controller.add_object(src, frequency, radio_filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = TRANSMISSION_RADIO //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "ADVP",
|
||||
"power" = use_power,
|
||||
"direction" = pump_direction?("release"):("siphon"),
|
||||
"checks" = pressure_checks,
|
||||
"input" = input_pressure_min,
|
||||
"output" = output_pressure_max,
|
||||
"external" = external_pressure_bound,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
radio_connection.post_signal(src, signal, radio_filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
|
||||
. = ..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/examine(mob/user)
|
||||
. = ..()
|
||||
if(Adjacent(user))
|
||||
. += "A small gauge in the corner reads [round(last_flow_rate, 0.1)] L/s; [round(last_power_draw)] W"
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if(signal.data["power"])
|
||||
update_use_power(text2num(signal.data["power"]))
|
||||
|
||||
if(signal.data["power_toggle"])
|
||||
update_use_power(!use_power)
|
||||
|
||||
if(signal.data["direction"])
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
|
||||
if(signal.data["checks"])
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
|
||||
if(signal.data["purge"])
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
|
||||
if(signal.data["stabalize"])
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
|
||||
if(signal.data["set_input_pressure"])
|
||||
input_pressure_min = between(0, text2num(signal.data["set_input_pressure"]), ONE_ATMOSPHERE*50)
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
output_pressure_max = between(0, text2num(signal.data["set_output_pressure"]), ONE_ATMOSPHERE*50)
|
||||
|
||||
if(signal.data["set_external_pressure"])
|
||||
external_pressure_bound = between(0, text2num(signal.data["set_external_pressure"]), ONE_ATMOSPHERE*50)
|
||||
|
||||
if(signal.data["status"])
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
return //do not update_icon
|
||||
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
|
||||
#undef DEFAULT_PRESSURE_DELTA
|
||||
|
||||
#undef EXTERNAL_PRESSURE_BOUND
|
||||
#undef INTERNAL_PRESSURE_BOUND
|
||||
#undef PRESSURE_CHECKS
|
||||
|
||||
#undef PRESSURE_CHECK_EXTERNAL
|
||||
#undef PRESSURE_CHECK_INPUT
|
||||
#undef PRESSURE_CHECK_OUTPUT
|
||||
#define DEFAULT_PRESSURE_DELTA 10000
|
||||
|
||||
#define EXTERNAL_PRESSURE_BOUND ONE_ATMOSPHERE
|
||||
#define INTERNAL_PRESSURE_BOUND 0
|
||||
#define PRESSURE_CHECKS 1
|
||||
|
||||
#define PRESSURE_CHECK_EXTERNAL 1
|
||||
#define PRESSURE_CHECK_INPUT 2
|
||||
#define PRESSURE_CHECK_OUTPUT 4
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump
|
||||
icon = 'icons/atmos/vent_pump.dmi'
|
||||
icon_state = "map_dp_vent"
|
||||
|
||||
//node2 is output port
|
||||
//node1 is input port
|
||||
|
||||
name = "Dual Port Air Vent"
|
||||
desc = "Has a valve and pump attached to it. There are two ports."
|
||||
|
||||
level = 1
|
||||
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
pipe_flags = PIPING_ALL_LAYER
|
||||
connect_types = CONNECT_TYPE_REGULAR|CONNECT_TYPE_SUPPLY|CONNECT_TYPE_SCRUBBER //connects to regular, supply and scrubbers pipes
|
||||
|
||||
var/pump_direction = 1 //0 = siphoning, 1 = releasing
|
||||
|
||||
var/external_pressure_bound = EXTERNAL_PRESSURE_BOUND
|
||||
var/input_pressure_min = INTERNAL_PRESSURE_BOUND
|
||||
var/output_pressure_max = DEFAULT_PRESSURE_DELTA
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
var/pressure_checks = PRESSURE_CHECK_EXTERNAL
|
||||
//1: Do not pass external_pressure_bound
|
||||
//2: Do not pass input_pressure_min
|
||||
//4: Do not pass output_pressure_max
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
|
||||
..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
icon = null
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Destroy()
|
||||
unregister_radio(src, frequency)
|
||||
. = ..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
|
||||
name = "Large Dual Port Air Vent"
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
|
||||
..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
|
||||
if(!check_icon_cache())
|
||||
return
|
||||
|
||||
cut_overlays()
|
||||
|
||||
var/vent_icon = "vent"
|
||||
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
vent_icon += "h"
|
||||
|
||||
if(!powered())
|
||||
vent_icon += "off"
|
||||
else
|
||||
vent_icon += "[use_power ? "[pump_direction ? "out" : "in"]" : "off"]"
|
||||
|
||||
add_overlay(icon_manager.get_atmos_icon("device", , , vent_icon))
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
return
|
||||
else
|
||||
if (node1)
|
||||
add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
if (node2)
|
||||
add_underlay(T, node2, dir, node2.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/hide(var/i)
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/process()
|
||||
..()
|
||||
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
|
||||
if(stat & (NOPOWER|BROKEN) || !use_power)
|
||||
return 0
|
||||
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
|
||||
var/power_draw = -1
|
||||
|
||||
//Figure out the target pressure difference
|
||||
var/pressure_delta = get_pressure_delta(environment)
|
||||
|
||||
if(pressure_delta > 0.5)
|
||||
if(pump_direction) //internal -> external
|
||||
if (node1 && (environment.temperature || air1.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(air1, environment, pressure_delta)
|
||||
power_draw = pump_gas(src, air1, environment, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network1)
|
||||
network1.update = 1
|
||||
else //external -> internal
|
||||
if (node2 && (environment.temperature || air2.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(environment, air2, pressure_delta, (network2)? network2.volume : 0)
|
||||
|
||||
//limit flow rate from turfs
|
||||
transfer_moles = min(transfer_moles, environment.total_moles*air2.volume/environment.volume) //group_multiplier gets divided out here
|
||||
power_draw = pump_gas(src, environment, air2, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network2)
|
||||
network2.update = 1
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/get_pressure_delta(datum/gas_mixture/environment)
|
||||
var/pressure_delta = DEFAULT_PRESSURE_DELTA
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
|
||||
if(pump_direction) //internal -> external
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, external_pressure_bound - environment_pressure) //increasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_INPUT)
|
||||
pressure_delta = min(pressure_delta, air1.return_pressure() - input_pressure_min) //decreasing the pressure here
|
||||
else //external -> internal
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, environment_pressure - external_pressure_bound) //decreasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_OUTPUT)
|
||||
pressure_delta = min(pressure_delta, output_pressure_max - air2.return_pressure()) //increasing the pressure here
|
||||
|
||||
return pressure_delta
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency)
|
||||
radio_controller.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = radio_controller.add_object(src, frequency, radio_filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = TRANSMISSION_RADIO //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "ADVP",
|
||||
"power" = use_power,
|
||||
"direction" = pump_direction?("release"):("siphon"),
|
||||
"checks" = pressure_checks,
|
||||
"input" = input_pressure_min,
|
||||
"output" = output_pressure_max,
|
||||
"external" = external_pressure_bound,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
radio_connection.post_signal(src, signal, radio_filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
|
||||
. = ..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/examine(mob/user)
|
||||
. = ..()
|
||||
if(Adjacent(user))
|
||||
. += "A small gauge in the corner reads [round(last_flow_rate, 0.1)] L/s; [round(last_power_draw)] W"
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if(signal.data["power"])
|
||||
update_use_power(text2num(signal.data["power"]))
|
||||
|
||||
if(signal.data["power_toggle"])
|
||||
update_use_power(!use_power)
|
||||
|
||||
if(signal.data["direction"])
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
|
||||
if(signal.data["checks"])
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
|
||||
if(signal.data["purge"])
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
|
||||
if(signal.data["stabalize"])
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
|
||||
if(signal.data["set_input_pressure"])
|
||||
input_pressure_min = between(0, text2num(signal.data["set_input_pressure"]), ONE_ATMOSPHERE*50)
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
output_pressure_max = between(0, text2num(signal.data["set_output_pressure"]), ONE_ATMOSPHERE*50)
|
||||
|
||||
if(signal.data["set_external_pressure"])
|
||||
external_pressure_bound = between(0, text2num(signal.data["set_external_pressure"]), ONE_ATMOSPHERE*50)
|
||||
|
||||
if(signal.data["status"])
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
return //do not update_icon
|
||||
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
|
||||
#undef DEFAULT_PRESSURE_DELTA
|
||||
|
||||
#undef EXTERNAL_PRESSURE_BOUND
|
||||
#undef INTERNAL_PRESSURE_BOUND
|
||||
#undef PRESSURE_CHECKS
|
||||
|
||||
#undef PRESSURE_CHECK_EXTERNAL
|
||||
#undef PRESSURE_CHECK_INPUT
|
||||
#undef PRESSURE_CHECK_OUTPUT
|
||||
|
||||
Reference in New Issue
Block a user