Atmospherics/Initialize (#16519)

This commit is contained in:
ShadowLarkens
2024-10-31 12:07:23 +01:00
committed by GitHub
parent 8b509623c0
commit 80ec15a777
24 changed files with 84 additions and 801 deletions
@@ -9,8 +9,8 @@
var/datum/pipe_network/network1
var/datum/pipe_network/network2
/obj/machinery/atmospherics/binary/New()
..()
/obj/machinery/atmospherics/binary/Initialize()
. = ..()
air1 = new
air2 = new
@@ -126,4 +126,4 @@
update_icon()
update_underlays()
return null
return null
@@ -24,8 +24,9 @@
density = TRUE
/obj/machinery/atmospherics/binary/circulator/New()
..()
/obj/machinery/atmospherics/binary/circulator/Initialize()
. = ..()
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
air1.volume = 400
@@ -149,4 +150,4 @@
return
src.set_dir(turn(src.dir, 90))
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
@@ -42,8 +42,11 @@
//2: Do not pass input_pressure_min
//4: Do not pass output_pressure_max
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
..()
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
icon = null
@@ -55,8 +58,8 @@
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
name = "Large Dual Port Air Vent"
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
..()
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/Initialize()
. = ..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
@@ -194,11 +197,6 @@
return 1
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/dp_vent_pump/examine(mob/user)
. = ..()
if(Adjacent(user))
@@ -27,10 +27,12 @@
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/passive_gate/New()
..()
/obj/machinery/atmospherics/binary/passive_gate/Initialize()
. = ..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/Destroy()
unregister_radio(src, frequency)
@@ -169,11 +171,6 @@
return 1
/obj/machinery/atmospherics/binary/passive_gate/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
@@ -37,10 +37,13 @@ Thus, the two variables affect pump operation are set in New():
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/pump/New()
..()
/obj/machinery/atmospherics/binary/pump/Initialize()
. = ..()
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/pump/Destroy()
unregister_radio(src, frequency)
@@ -166,11 +169,6 @@ Thus, the two variables affect pump operation are set in New():
return data
/obj/machinery/atmospherics/binary/pump/Initialize()
. = ..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0