diff --git a/code/ATMOSPHERICS/components/unary/outlet_injector.dm b/code/ATMOSPHERICS/components/unary/outlet_injector.dm
index 138c3fd40fe..d603da8cd14 100644
--- a/code/ATMOSPHERICS/components/unary/outlet_injector.dm
+++ b/code/ATMOSPHERICS/components/unary/outlet_injector.dm
@@ -1,6 +1,6 @@
//Basically a one way passive valve. If the pressure inside is greater than the environment then gas will flow passively,
//but it does not permit gas to flow back from the environment into the injector. Can be turned off to prevent any gas flow.
-//When it recieves the "inject" signal, it will try to pump it's entire contents into the environment regardless of pressure, using power.
+//When it receives the "inject" signal, it will try to pump it's entire contents into the environment regardless of pressure, using power.
/obj/machinery/atmospherics/unary/outlet_injector
icon = 'icons/atmos/injector.dmi'
diff --git a/code/game/machinery/atmo_control.dm b/code/game/machinery/atmo_control.dm
index 1889e642bac..a62da66d770 100644
--- a/code/game/machinery/atmo_control.dm
+++ b/code/game/machinery/atmo_control.dm
@@ -238,11 +238,11 @@ Max Output Pressure: [output_pressure] kPa
"}
signal.source = src
if(href_list["in_refresh_status"])
input_info = null
- signal.data = list ("tag" = input_tag, "status")
+ signal.data = list ("tag" = input_tag, "status" = 1)
if(href_list["in_toggle_injector"])
input_info = null
- signal.data = list ("tag" = input_tag, "power_toggle")
+ signal.data = list ("tag" = input_tag, "power_toggle" = 1)
if(href_list["in_set_flowrate"])
input_info = null
@@ -250,11 +250,11 @@ Max Output Pressure: [output_pressure] kPa
"}
if(href_list["out_refresh_status"])
output_info = null
- signal.data = list ("tag" = output_tag, "status")
+ signal.data = list ("tag" = output_tag, "status" = 1)
if(href_list["out_toggle_power"])
output_info = null
- signal.data = list ("tag" = output_tag, "power_toggle")
+ signal.data = list ("tag" = output_tag, "power_toggle" = 1)
if(href_list["out_set_pressure"])
output_info = null
@@ -304,7 +304,7 @@ Max Output Pressure: [output_pressure] kPa
"}
if(output_info)
var/power = (output_info["power"])
var/pressure_limit = output_info["external"]
- output += {"Core Outpump: [power?("On"):("Off")] Refresh
+ output += {"Core Outpump: [power?("Open"):("On Hold")] Refresh
Min Core Pressure: [pressure_limit] kPa
"}
output += "Command: Toggle Power Set Pressure
"
@@ -352,11 +352,11 @@ Min Core Pressure: [pressure_limit] kPa
"}
signal.source = src
if(href_list["in_refresh_status"])
input_info = null
- signal.data = list ("tag" = input_tag, "status")
+ signal.data = list ("tag" = input_tag, "status" = 1)
if(href_list["in_toggle_injector"])
input_info = null
- signal.data = list ("tag" = input_tag, "power_toggle")
+ signal.data = list ("tag" = input_tag, "power_toggle" = 1)
if(href_list["in_set_flowrate"])
input_info = null
@@ -364,11 +364,11 @@ Min Core Pressure: [pressure_limit] kPa
"}
if(href_list["out_refresh_status"])
output_info = null
- signal.data = list ("tag" = output_tag, "status")
+ signal.data = list ("tag" = output_tag, "status" = 1)
if(href_list["out_toggle_power"])
output_info = null
- signal.data = list ("tag" = output_tag, "power_toggle")
+ signal.data = list ("tag" = output_tag, "power_toggle" = 1)
if(href_list["out_set_pressure"])
output_info = null
@@ -468,7 +468,7 @@ Rate: [volume_rate] L/sec
"}
signal.source = src
signal.data = list(
"tag" = device_tag,
- "status",
+ "status" = 1,
"sigtype"="command"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
@@ -486,7 +486,7 @@ Rate: [volume_rate] L/sec
"}
signal.source = src
signal.data = list(
"tag" = device_tag,
- "power_toggle",
+ "power_toggle" = 1,
"sigtype"="command"
)
@@ -501,7 +501,7 @@ Rate: [volume_rate] L/sec
"}
signal.source = src
signal.data = list(
"tag" = device_tag,
- "inject",
+ "inject" = 1,
"sigtype"="command"
)