mirror of
https://github.com/VOREStation/VOREStation.git
synced 2026-07-12 23:54:24 +01:00
SMES Exploit Fix
- RCON consoles ignored SMES I/O limits, meaning you could set SMES to charge/discharge at unlimited values. - SMESs now properly trim the value when it is above maximal limit (or below 0) - Also commented the code, while i was in it
This commit is contained in:
@@ -1,6 +1,11 @@
|
||||
// Constructable SMES version (based on SMES Coils)
|
||||
// BUILDABLE SMES(Superconducting Magnetic Energy Storage) UNIT
|
||||
//
|
||||
// Last Change 1.1.2015 by Atlantis - Happy New Year!
|
||||
//
|
||||
// This is subtype of SMES that should be normally used. It can be constructed, deconstructed and hacked.
|
||||
// It also supports RCON System which allows you to operate it remotely, if properly set.
|
||||
|
||||
//Construction Items
|
||||
//Construction Item
|
||||
/obj/item/weapon/smes_coil
|
||||
name = "superconductive magnetic coil"
|
||||
desc = "Heavy duty superconductive magnetic coil, mainly used in construction of SMES units."
|
||||
@@ -23,6 +28,10 @@
|
||||
charge = 0
|
||||
should_be_mapped = 1
|
||||
|
||||
// Proc: process()
|
||||
// Parameters: None
|
||||
// Description: Uses parent process, but if grounding wire is cut causes sparks to fly around.
|
||||
// This also causes the SMES to quickly discharge, and has small chance of damaging output APCs.
|
||||
/obj/machinery/power/smes/buildable/process()
|
||||
if(!grounding && (Percentage() > 5))
|
||||
var/datum/effect/effect/system/spark_spread/s = new /datum/effect/effect/system/spark_spread
|
||||
@@ -34,13 +43,18 @@
|
||||
|
||||
..()
|
||||
|
||||
|
||||
// Proc: attack_ai()
|
||||
// Parameters: None
|
||||
// Description: AI requires the RCON wire to be intact to operate the SMES.
|
||||
/obj/machinery/power/smes/buildable/attack_ai()
|
||||
if(RCon)
|
||||
..()
|
||||
else // RCON wire cut
|
||||
usr << "<span class='warning'>Connection error: Destination Unreachable.</span>"
|
||||
|
||||
// Proc: New()
|
||||
// Parameters: None
|
||||
// Description: Adds standard components for this SMES, and forces recalculation of properties.
|
||||
/obj/machinery/power/smes/buildable/New()
|
||||
component_parts = list()
|
||||
component_parts += new /obj/item/stack/cable_coil(src,30)
|
||||
@@ -54,11 +68,17 @@
|
||||
recalc_coils()
|
||||
..()
|
||||
|
||||
// Proc: attack_hand()
|
||||
// Parameters: None
|
||||
// Description: Opens the UI as usual, and if cover is removed opens the wiring panel.
|
||||
/obj/machinery/power/smes/buildable/attack_hand()
|
||||
..()
|
||||
if(open_hatch)
|
||||
wires.Interact(usr)
|
||||
|
||||
// Proc: recalc_coils()
|
||||
// Parameters: None
|
||||
// Description: Updates properties (IO, capacity, etc.) of this SMES by checking internal components.
|
||||
/obj/machinery/power/smes/buildable/proc/recalc_coils()
|
||||
if ((cur_coils <= max_coils) && (cur_coils >= 1))
|
||||
capacity = 0
|
||||
@@ -73,6 +93,10 @@
|
||||
else
|
||||
return 0
|
||||
|
||||
// Proc: total_system_failure()
|
||||
// Parameters: 2 (intensity - how strong the failure is, user - person which caused the failure)
|
||||
// Description: Checks the sensors for alerts. If change (alerts cleared or detected) occurs, calls for icon update.
|
||||
/obj/machinery/power/smes/buildable/proc/total_system_failure(var/intensity = 0, var/mob/user as mob)
|
||||
// SMESs store very large amount of power. If someone screws up (ie: Disables safeties and attempts to modify the SMES) very bad things happen.
|
||||
// Bad things are based on charge percentage.
|
||||
// Possible effects:
|
||||
@@ -82,7 +106,7 @@
|
||||
// Light Overload - X% chance to overload each lighting circuit in connected powernet. APC based.
|
||||
// APC Failure - X% chance to destroy APC causing very weak explosion too. Won't cause hull breach or serious harm.
|
||||
// SMES Explosion - X% chance to destroy the SMES, in moderate explosion. May cause small hull breach.
|
||||
/obj/machinery/power/smes/buildable/proc/total_system_failure(var/intensity = 0, var/mob/user as mob)
|
||||
|
||||
if (!intensity)
|
||||
return
|
||||
|
||||
@@ -187,7 +211,9 @@
|
||||
|
||||
|
||||
|
||||
// Gets powernet APCs and overloads lights or breaks the APC completely, depending on percentages.
|
||||
// Proc: apcs_overload()
|
||||
// Parameters: 2 (failure_chance - chance to actually break the APC, overload_chance - Chance of breaking lights)
|
||||
// Description: Damages output powernet by power surge. Destroys few APCs and lights, depending on parameters.
|
||||
/obj/machinery/power/smes/buildable/proc/apcs_overload(var/failure_chance, var/overload_chance)
|
||||
if (!src.powernet)
|
||||
return
|
||||
@@ -200,7 +226,9 @@
|
||||
if (prob(failure_chance))
|
||||
A.set_broken()
|
||||
|
||||
// Failing SMES has special icon overlay.
|
||||
// Proc: update_icon()
|
||||
// Parameters: None
|
||||
// Description: Allows us to use special icon overlay for critical SMESs
|
||||
/obj/machinery/power/smes/buildable/update_icon()
|
||||
if (failing)
|
||||
overlays.Cut()
|
||||
@@ -208,6 +236,9 @@
|
||||
else
|
||||
..()
|
||||
|
||||
// Proc: attackby()
|
||||
// Parameters: 2 (W - object that was used on this machine, user - person which used the object)
|
||||
// Description: Handles tool interaction. Allows deconstruction/upgrading/fixing.
|
||||
/obj/machinery/power/smes/buildable/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob)
|
||||
// No more disassembling of overloaded SMESs. You broke it, now enjoy the consequences.
|
||||
if (failing)
|
||||
@@ -283,18 +314,30 @@
|
||||
else
|
||||
usr << "\red You can't insert more coils to this SMES unit!"
|
||||
|
||||
// Proc: toggle_input()
|
||||
// Parameters: None
|
||||
// Description: Switches the input on/off depending on previous setting
|
||||
/obj/machinery/power/smes/buildable/proc/toggle_input()
|
||||
input_attempt = !input_attempt
|
||||
update_icon()
|
||||
|
||||
// Proc: toggle_output()
|
||||
// Parameters: None
|
||||
// Description: Switches the output on/off depending on previous setting
|
||||
/obj/machinery/power/smes/buildable/proc/toggle_output()
|
||||
output_attempt = !output_attempt
|
||||
update_icon()
|
||||
|
||||
// Proc: set_input()
|
||||
// Parameters: 1 (new_input - New input value in Watts)
|
||||
// Description: Sets input setting on this SMES. Trims it if limits are exceeded.
|
||||
/obj/machinery/power/smes/buildable/proc/set_input(var/new_input = 0)
|
||||
input_level = new_input
|
||||
input_level = between(0, new_input, input_level_max)
|
||||
update_icon()
|
||||
|
||||
// Proc: set_output()
|
||||
// Parameters: 1 (new_output - New output value in Watts)
|
||||
// Description: Sets output setting on this SMES. Trims it if limits are exceeded.
|
||||
/obj/machinery/power/smes/buildable/proc/set_output(var/new_output = 0)
|
||||
output_level = new_output
|
||||
output_level = between(0, new_output, output_level_max)
|
||||
update_icon()
|
||||
Reference in New Issue