@@ -257,7 +257,7 @@
if("max")
target_pressure = max_pressure_setting
if("set")
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure Control",src.target_pressure) as num
var/new_pressure = tgui_input_number(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure Control",src.target_pressure,max_pressure_setting,0)
src.target_pressure = between(0, new_pressure, max_pressure_setting)
if("set_flow_rate")
@@ -268,7 +268,7 @@
if("max")
set_flow_rate = air1.volume
if("set")
var/new_flow_rate = input(usr,"Enter new flow rate limit (0-[air1.volume]L/s)","Flow Rate Control",src.set_flow_rate) as num
var/new_flow_rate = tgui_input_number(usr,"Enter new flow rate limit (0-[air1.volume]L/s)","Flow Rate Control",src.set_flow_rate,air1.volume,0)
src.set_flow_rate = between(0, new_flow_rate, air1.volume)
update_icon()
@@ -222,7 +222,7 @@ Thus, the two variables affect pump operation are set in New():
if("max")
target_pressure = max_pressure_setting
if("set")
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure control",src.target_pressure) as num
var/new_pressure = tgui_input_number(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure control",src.target_pressure,max_pressure_setting,0)
src.target_pressure = between(0, new_pressure, max_pressure_setting)
. = TRUE
@@ -170,7 +170,7 @@
if("set_flow_rate")
if(!configuring || use_power)
return
var/new_flow_rate = input(usr,"Enter new flow rate limit (0-[max_flow_rate]L/s)","Flow Rate Control",set_flow_rate) as num
var/new_flow_rate = tgui_input_number(usr,"Enter new flow rate limit (0-[max_flow_rate]L/s)","Flow Rate Control",set_flow_rate,max_flow_rate,0)
set_flow_rate = between(0, new_flow_rate, max_flow_rate)
. = TRUE
if("switch_mode")
@@ -183,7 +183,7 @@
. = TRUE
if(!configuring || use_power)
return
var/new_flow_rate = input(usr,"Enter new flow rate limit (0-[max_flow_rate]L/s)","Flow Rate Control",set_flow_rate) as num
var/new_flow_rate = tgui_input_number(usr,"Enter new flow rate limit (0-[max_flow_rate]L/s)","Flow Rate Control",set_flow_rate,max_flow_rate,0)
set_flow_rate = between(0, new_flow_rate, max_flow_rate)
if("switch_mode")
. = TRUE
@@ -265,7 +265,7 @@
if(non_locked < 1)
return
var/new_con = (input(usr,"Enter a new concentration (0-[round(remain_con * 100, 0.5)])%","Concentration control", min(remain_con, old_con)*100) as num) / 100
var/new_con = (tgui_input_number(usr,"Enter a new concentration (0-[round(remain_con * 100, 0.5)])%","Concentration control", min(remain_con, old_con)*100, round(remain_con * 100, 0.5), 0)) / 100
//cap it between 0 and the max remaining concentration
new_con = between(0, new_con, remain_con)
@@ -20,7 +20,7 @@
var/hibernate = 0 //Do we even process?
var/scrubbing = 1 //0 = siphoning, 1 = scrubbing
var/list/scrubbing_gas = list("carbon_dioxide")
var/list/scrubbing_gas = list("carbon_dioxide", "phoron")
var/panic = 0 //is this scrubber panicked?