mirror of
https://github.com/VOREStation/VOREStation.git
synced 2026-07-13 08:04:22 +01:00
Atmospheric Device Changes, Added Volume Pump (#18261)
* Volume Pump added, Can now Connect some devices to the General Atmos Controller and Large Tank Controller * Corrected Linting Errors. Added the ability to print tank control circuits. * Undefined some defined as per linter. * Code style adjustments * fixes these * Code Standards --------- Co-authored-by: Cameron Lennox <killer65311@gmail.com>
This commit is contained in:
@@ -254,3 +254,25 @@ Thus, the two variables affect pump operation are set in New():
|
||||
span_notice("You have unfastened \the [src]."), \
|
||||
"You hear ratchet.")
|
||||
deconstruct()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power
|
||||
icon = 'icons/atmos/volume_pump.dmi'
|
||||
icon_state = "map_off"
|
||||
construction_type = /obj/item/pipe/directional
|
||||
pipe_state = "volumepump"
|
||||
level = 1
|
||||
|
||||
name = "high power gas pump"
|
||||
desc = "A pump that moves gas from one place to another. Has double the power rating of the standard gas pump."
|
||||
|
||||
power_rating = 15000 //15000 W ~ 20 HP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/on
|
||||
use_power = USE_POWER_IDLE
|
||||
icon_state = "map_on"
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/update_icon()
|
||||
if(!powered())
|
||||
icon_state = "off"
|
||||
else
|
||||
icon_state = "[use_power ? "on" : "off"]"
|
||||
|
||||
@@ -1,21 +1,307 @@
|
||||
/obj/machinery/atmospherics/binary/pump/high_power
|
||||
/*
|
||||
Every cycle, the pump uses the air in air_in to try and move a specific volume of gas into air_out.
|
||||
|
||||
node1, air1, network1 correspond to input
|
||||
node2, air2, network2 correspond to output
|
||||
|
||||
Thus, the two variables affect pump operation are set in New():
|
||||
air1.volume
|
||||
This is the volume of gas available to the pump that may be transfered to the output
|
||||
air2.volume
|
||||
Higher quantities of this cause more air to be perfected later
|
||||
but overall network volume is also increased as this increases...
|
||||
*/
|
||||
#define VOLUME_PUMP_MAX_OUTPUT_PRESSURE 9000 // kpa
|
||||
#define VOLUME_PUMP_LEAK_AMOUNT 0.04 // About 4% of the volume moved will leak.
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump
|
||||
icon = 'icons/atmos/volume_pump.dmi'
|
||||
icon_state = "map_off"
|
||||
construction_type = /obj/item/pipe/directional
|
||||
pipe_state = "volumepump"
|
||||
level = 1
|
||||
var/base_icon = "pump"
|
||||
|
||||
name = "high power gas pump"
|
||||
desc = "A pump that moves gas from one place to another. Has double the power rating of the standard gas pump."
|
||||
name = "volumetric gas pump"
|
||||
desc = "A pump that moves gas by volume"
|
||||
|
||||
power_rating = 15000 //15000 W ~ 20 HP
|
||||
use_power = USE_POWER_OFF
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 15000 //15000 W ~ 20.4 HP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/on
|
||||
use_power = USE_POWER_IDLE
|
||||
var/max_transfer_rate = ATMOS_DEFAULT_VOLUME_PUMP // Ls
|
||||
var/transfer_rate = 20 // L
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
var/overclocked = FALSE
|
||||
var/mutable_appearance/overclock_overlay
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/Initialize(mapload)
|
||||
. = ..()
|
||||
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/Destroy()
|
||||
unregister_radio(src, frequency)
|
||||
. = ..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/on
|
||||
icon_state = "map_on"
|
||||
use_power = USE_POWER_IDLE
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/update_icon()
|
||||
/obj/machinery/atmospherics/binary/volume_pump/fuel
|
||||
icon_state = "map_off-fuel"
|
||||
base_icon = "pump-fuel"
|
||||
icon_connect_type = "-fuel"
|
||||
connect_types = CONNECT_TYPE_FUEL
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/fuel/on
|
||||
icon_state = "map_on-fuel"
|
||||
use_power = USE_POWER_IDLE
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/aux
|
||||
icon_state = "map_off-aux"
|
||||
base_icon = "pump-aux"
|
||||
icon_connect_type = "-aux"
|
||||
connect_types = CONNECT_TYPE_AUX
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/aux/on
|
||||
icon_state = "map_on-aux"
|
||||
use_power = USE_POWER_IDLE
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/update_icon()
|
||||
if(!powered())
|
||||
icon_state = "off"
|
||||
else
|
||||
icon_state = "[use_power ? "on" : "off"]"
|
||||
|
||||
overclock_overlay = mutable_appearance('icons/atmos/volume_pump_overclock.dmi', "vpumpoverclock")
|
||||
if(powered() && use_power && overclocked)
|
||||
add_overlay(overclock_overlay)
|
||||
else
|
||||
cut_overlay(overclock_overlay)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
add_underlay(T, node1, turn(dir, -180), node1?.icon_connect_type)
|
||||
add_underlay(T, node2, dir, node2?.icon_connect_type)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/hide(var/i)
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/process()
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
var/power_draw = 0
|
||||
|
||||
if((stat & (NOPOWER|BROKEN)) || !use_power)
|
||||
return
|
||||
|
||||
var/input_starting_moles = air1.total_moles
|
||||
var/output_starting_pressure = air2.return_pressure()
|
||||
|
||||
// The pump will refuse to do anything if the pressure is too high or low, unless it is overclocked.
|
||||
if((input_starting_moles < MINIMUM_MOLES_TO_PUMP || output_starting_pressure > VOLUME_PUMP_MAX_OUTPUT_PRESSURE) && !overclocked)
|
||||
return
|
||||
|
||||
var/transfer_ratio = transfer_rate / air1.volume
|
||||
if(!transfer_ratio)
|
||||
return
|
||||
|
||||
var/datum/gas_mixture/removed = air1.remove_ratio(transfer_ratio)
|
||||
var/transfer_moles = removed.total_moles
|
||||
last_flow_rate = (transfer_moles/input_starting_moles)*air1.volume
|
||||
|
||||
// Some gases will leak if overclocked. Trade off for no pump limits.
|
||||
if(overclocked)
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
var/datum/gas_mixture/leaked = removed.remove_ratio(VOLUME_PUMP_LEAK_AMOUNT)
|
||||
environment.merge(leaked)
|
||||
|
||||
air2.merge(removed)
|
||||
|
||||
// This part is necessary, as the function pump_gas has limits that reduces the volume pump to just a glorified pressure pump.
|
||||
// The gas pump does not care about trying to meet a specific pressure. It will keep moving gas till a pressure limit is reached.
|
||||
power_draw = (transfer_moles/input_starting_moles)*power_rating
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
if(network1)
|
||||
network1.update = TRUE
|
||||
|
||||
if(network2)
|
||||
network2.update = TRUE
|
||||
|
||||
return TRUE
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, radio_filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return FALSE
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = TRANSMISSION_RADIO //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "AGP",
|
||||
"power" = use_power,
|
||||
"transfer_rate" = transfer_rate,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
|
||||
radio_connection.post_signal(src, signal, radio_filter = RADIO_ATMOSIA)
|
||||
|
||||
return TRUE
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/tgui_interact(mob/user, datum/tgui/ui)
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
ui = SStgui.try_update_ui(user, src, ui)
|
||||
if(!ui)
|
||||
ui = new(user, src, "GasPump", name)
|
||||
ui.open()
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/tgui_data(mob/user)
|
||||
// this is the data which will be sent to the ui
|
||||
var/list/data = list(
|
||||
"on" = use_power,
|
||||
"rate" = transfer_rate*100,
|
||||
"max_rate" = max_transfer_rate,
|
||||
"last_flow_rate" = last_flow_rate*10,
|
||||
"last_power_draw" = last_power_draw,
|
||||
"max_power_draw" = power_rating,
|
||||
)
|
||||
|
||||
return data
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return FALSE
|
||||
|
||||
if(signal.data["power"])
|
||||
if(text2num(signal.data["power"]))
|
||||
update_use_power(USE_POWER_IDLE)
|
||||
else
|
||||
update_use_power(USE_POWER_OFF)
|
||||
|
||||
if("power_toggle" in signal.data)
|
||||
update_use_power(!use_power)
|
||||
|
||||
if(signal.data["set_volume_rate"])
|
||||
transfer_rate = between(0, text2num(signal.data["set_volume_rate"]), air1.volume)
|
||||
|
||||
if(signal.data["status"])
|
||||
broadcast_status()
|
||||
return //do not update_icon
|
||||
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/attack_ghost(mob/user)
|
||||
tgui_interact(user)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/attack_hand(mob/user)
|
||||
if(..())
|
||||
return
|
||||
add_fingerprint(user)
|
||||
if(!allowed(user))
|
||||
to_chat(user, span_warning("Access denied."))
|
||||
return
|
||||
tgui_interact(user)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/tgui_act(action, params, datum/tgui/ui)
|
||||
if(..())
|
||||
return TRUE
|
||||
|
||||
switch(action)
|
||||
if("power")
|
||||
update_use_power(!use_power)
|
||||
. = TRUE
|
||||
if("set_press")
|
||||
var/press = params["press"]
|
||||
switch(press)
|
||||
if("min")
|
||||
transfer_rate = 0
|
||||
if("max")
|
||||
transfer_rate = max_transfer_rate
|
||||
if("set")
|
||||
var/new_rate = tgui_input_number(ui.user,"Enter new transfer rate (0-[max_transfer_rate] L/s)","Flow Control",src.transfer_rate, max_transfer_rate, 0)
|
||||
src.transfer_rate = between(0, new_rate, max_transfer_rate)
|
||||
. = TRUE
|
||||
|
||||
add_fingerprint(ui.user)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/attackby(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if (W.has_tool_quality(TOOL_WRENCH))
|
||||
wrench_act(W, user)
|
||||
|
||||
if (W.has_tool_quality(TOOL_MULTITOOL))
|
||||
multitool_act(W, user)
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/examine(mob/user)
|
||||
. = ..()
|
||||
. += "This device is designed to move large volumes of gasses quickly, but with no gurantee of exact pressures.\
|
||||
Meaning that this can naievely over-pressurize pipes and devices past the device's designed limit."
|
||||
. += span_bold("The [src]'s pressure limit is [VOLUME_PUMP_MAX_OUTPUT_PRESSURE].")
|
||||
. += span_notice("Its pressure limits could be [overclocked ? "en" : "dis"]abled with a" + span_bold("multitool") + ".")
|
||||
if(overclocked)
|
||||
. += "Its warning light is on[use_power ? " and it's spewing gas!" : "."]"
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/proc/wrench_act(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if (!(stat & NOPOWER) && use_power)
|
||||
to_chat(user, span_warning("You cannot unwrench this [src], turn it off first."))
|
||||
return TRUE
|
||||
if(!can_unwrench())
|
||||
to_chat(user, span_warning("You cannot unwrench this [src], it too exerted due to internal pressure."))
|
||||
add_fingerprint(user)
|
||||
return TRUE
|
||||
playsound(src, W.usesound, 50, 1)
|
||||
to_chat(user, span_notice("You begin to unfasten \the [src]..."))
|
||||
if (do_after(user, 40 * W.toolspeed))
|
||||
user.visible_message( \
|
||||
span_infoplain(span_bold("\The [user]") + " unfastens \the [src]."), \
|
||||
span_notice("You have unfastened \the [src]."), \
|
||||
"You hear ratchet.")
|
||||
deconstruct()
|
||||
|
||||
/obj/machinery/atmospherics/binary/volume_pump/proc/multitool_act(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if(!overclocked)
|
||||
overclocked = TRUE
|
||||
to_chat(user, span_notice("The pump makes a grinding noise and air starts to hiss out as you disable its pressure limits."))
|
||||
else
|
||||
overclocked = FALSE
|
||||
to_chat(user, span_notice("The pump quiets down as you turn its limiters back on."))
|
||||
update_icon()
|
||||
|
||||
#undef VOLUME_PUMP_MAX_OUTPUT_PRESSURE
|
||||
#undef VOLUME_PUMP_LEAK_AMOUNT
|
||||
|
||||
Reference in New Issue
Block a user