From 0ff5d021de8730f0df95c9d59b0b5139b8c92700 Mon Sep 17 00:00:00 2001 From: Walter0o Date: Thu, 10 Jul 2014 18:21:00 +0200 Subject: [PATCH] fixes #5449 missing variable updating lead to APCs stuck in green status during powersinks. --- code/modules/power/apc.dm | 1 + 1 file changed, 1 insertion(+) diff --git a/code/modules/power/apc.dm b/code/modules/power/apc.dm index 42ab0a1812..a1796aa5c3 100644 --- a/code/modules/power/apc.dm +++ b/code/modules/power/apc.dm @@ -1288,6 +1288,7 @@ chargecount++ else chargecount = 0 + charging = 0 if(chargecount == 10)