Commit Graph

11 Commits

Author SHA1 Message Date
Kelenius 10de826ca3 Removes FPRINT and TABLEPASS flags 2015-01-23 22:27:32 +03:00
Atlantiscze a9e1f920fd Powersink Load Fix
- Apparently i forgot to add check for used amount of power when reworking powersink, causing it to drain 2kW from each APC, even above drain cap.
2014-12-29 20:36:50 +01:00
Amunak 4882074739 Code formatting, EOL at EOF fixes, refactoring 2014-12-18 03:11:49 +01:00
Atlantiscze 61990872d8 Merge branch 'dev' of https://github.com/Baystation12/Baystation12 into powernet-sensors-mk2 2014-11-19 13:15:40 +01:00
Zuhayr 90d65aed57 Removed attack_paw, attack_animal and attack_slime. 2014-11-13 17:15:29 +10:30
Atlantiscze 835d04290c Modifications to sensors code
- More stuff now triggers powernet warnings: People getting shocked by machinery (primarily door, but can be anything else powered by APC), and grilles. Thanks to @mwerezak for suggestion.
- Monitoring computer now has slightly different icon_state when it detects powernet warning. This is checked and updated every 5 MC ticks (ie, slightly delayed)
- Fixes ocassional runtime in powernet_sensor.dm
- Powersinks buffed a bit more. Drain rate changed from 0.6MW to 1MW. 1MW is full output of main engine SMES.
- Powersinks also dissipate small amount of internal energy charge over time. (20kW)
2014-11-12 14:54:56 +01:00
Atlantiscze f29cd211e6 Implements better powernet warning system (as suggested by mwerezak) 2014-11-12 12:33:23 +01:00
Atlantiscze ddaac3e175 Powernet Sensor
- Adds remote powernet sensors, power monitoring computers use these by default to monitor power around the station. Default range is 1 Z level + long range versions of sensors
- Powernet sensors mapped in, each subgrid has it's own one (ie: substations compatible)
- Telecomms, mining, research and engineering outposts have long range versions installed, visible even cross-Zlevels
- Powersinks and ninja gloves now trigger problem warning in powernets they affect. This warning is visible to anyone using power monitoring console. TODO: Add more stuff that triggers warnings.
- Powersinks now properly drain APC cells using CELLRATE (@2000W per APC max.)
- Powersinks buffed a bit, to compensate for CELLRATE change (previous line)
2014-11-12 07:07:08 +01:00
PsiOmega a1ee4e766b Basically ripped over /tg/'s powernet and cable code into our own codebase.
Keeps Z-level code as it was.
Modifies/restores powernet procs as necessary to match our own implementation changes.
2014-10-13 17:13:04 +02:00
Zuhayr 9e7fe6d700 Rewrote autolathe, changed all m_amt and g_amt to a list called 'matter'. Updated RCD vars in view of this. 2014-06-11 01:14:38 +09:30
johnsonmt88@gmail.com d36387607f More file structure stuff.
- The folders themselves are now finished
- Next I'll go through each file and organize them
- Lastly I'll start pulling the object definitions out of /code/defines/ and put them into their respective files.

**Note to committers**
Make sure the .dme file updates when you update to this revision. If necessary delete the .dme and svn-update.

git-svn-id: http://tgstation13.googlecode.com/svn/trunk@4546 316c924e-a436-60f5-8080-3fe189b3f50e
2012-08-26 01:20:02 +00:00