mirror of
https://github.com/VOREStation/VOREStation.git
synced 2026-05-18 04:41:27 +01:00
0fd2c24268
* cleans up some more update Dialog * . * pod UI * . * modern rcon console * . * no dupe tags * . * nbeeds a recode * . * . * ice cream as tgui * , * legacy drone fab * more a POI object * . * missing dels * navbeacon * eh that is part of the default now * del useless list * . * . * . * retail scanner * better * finish retail * . * be gone * . * .
89 lines
2.0 KiB
Plaintext
89 lines
2.0 KiB
Plaintext
/datum/wires/alarm
|
|
holder_type = /obj/machinery/alarm
|
|
wire_count = 5
|
|
proper_name = "Air alarm"
|
|
|
|
/datum/wires/alarm/New(atom/_holder)
|
|
wires = list(
|
|
WIRE_IDSCAN, WIRE_MAIN_POWER1, WIRE_SYPHON,
|
|
WIRE_AI_CONTROL, WIRE_AALARM
|
|
)
|
|
return ..()
|
|
|
|
/datum/wires/alarm/interactable(mob/user)
|
|
var/obj/machinery/alarm/A = holder
|
|
if(A.panel_open)
|
|
return TRUE
|
|
return FALSE
|
|
|
|
/datum/wires/alarm/get_status()
|
|
var/obj/machinery/alarm/A = holder
|
|
. = ..()
|
|
. += "The Air Alarm is [A.locked ? "locked." : "unlocked."]"
|
|
. += "The Air Alarm is [(A.shorted || (A.stat & (NOPOWER|BROKEN))) ? "offline." : "working properly!"]"
|
|
. += "The 'AI control allowed' light is [A.aidisabled ? "off" : "on"]."
|
|
|
|
/datum/wires/alarm/on_cut(wire, mend)
|
|
var/obj/machinery/alarm/A = holder
|
|
switch(wire)
|
|
if(WIRE_IDSCAN)
|
|
if(!mend)
|
|
A.locked = TRUE
|
|
|
|
if(WIRE_MAIN_POWER1)
|
|
A.shock(usr, 50)
|
|
A.shorted = !mend
|
|
A.update_icon()
|
|
|
|
if(WIRE_AI_CONTROL)
|
|
A.aidisabled = !mend
|
|
|
|
if(WIRE_SYPHON)
|
|
if(!mend)
|
|
A.mode = 3 // MODE_PANIC
|
|
A.apply_mode()
|
|
|
|
if(WIRE_AALARM)
|
|
if(A.alarm_area.atmosalert(2, A))
|
|
A.post_alert(2)
|
|
A.update_icon()
|
|
..()
|
|
|
|
/datum/wires/alarm/on_pulse(wire)
|
|
var/obj/machinery/alarm/A = holder
|
|
switch(wire)
|
|
if(WIRE_IDSCAN)
|
|
A.locked = !A.locked
|
|
|
|
if(WIRE_MAIN_POWER1)
|
|
if(!A.shorted)
|
|
A.shorted = TRUE
|
|
for(var/obj/machinery/alarm/AA in A.alarm_area)
|
|
AA.update_icon()
|
|
addtimer(CALLBACK(src, PROC_REF(clear_short)), 20 MINUTES, TIMER_DELETE_ME)
|
|
|
|
if(WIRE_AI_CONTROL)
|
|
if(!A.aidisabled)
|
|
A.aidisabled = TRUE
|
|
addtimer(VARSET_CALLBACK(A, aidisabled, FALSE), 10 SECONDS, TIMER_DELETE_ME)
|
|
|
|
if(WIRE_SYPHON)
|
|
if(A.mode == 1) // MODE_SCRUB
|
|
A.mode = 3 // MODE_PANIC
|
|
else
|
|
A.mode = 1 // MODE_SCRUB
|
|
A.apply_mode()
|
|
|
|
if(WIRE_AALARM)
|
|
if(A.alarm_area.atmosalert(0, A))
|
|
A.post_alert(0)
|
|
A.update_icon()
|
|
|
|
/datum/wires/alarm/proc/clear_short()
|
|
SHOULD_NOT_OVERRIDE(TRUE)
|
|
PRIVATE_PROC(TRUE)
|
|
var/obj/machinery/alarm/A = holder
|
|
if(A && A.shorted)
|
|
A.shorted = FALSE
|
|
A.update_icon()
|