mirror of
https://github.com/yogstation13/Yogstation.git
synced 2025-02-26 09:04:50 +00:00
makes air flow; fixes EVERYTHING
This commit is contained in:
@@ -7,7 +7,7 @@ Passive gate is similar to the regular pump except:
|
||||
|
||||
*/
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate
|
||||
icon_state = "passgate_map"
|
||||
|
||||
name = "passive gate"
|
||||
@@ -22,20 +22,20 @@ Passive gate is similar to the regular pump except:
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/Destroy()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/Destroy()
|
||||
if(radio_controller)
|
||||
radio_controller.remove_object(src,frequency)
|
||||
..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/update_icon_nopipes()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/update_icon_nopipes()
|
||||
if(!on)
|
||||
icon_state = "passgate_off"
|
||||
overlays.Cut()
|
||||
return
|
||||
|
||||
overlays += getpipeimage('icons/obj/atmospherics/binary_devices.dmi', "passgate_on")
|
||||
overlays += getpipeimage('icons/obj/atmospherics/components/binary_devices.dmi', "passgate_on")
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/process_atmos()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/process_atmos()
|
||||
..()
|
||||
if(!on)
|
||||
return 0
|
||||
@@ -67,13 +67,13 @@ Passive gate is similar to the regular pump except:
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/proc/set_frequency(new_frequency)
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/proc/set_frequency(new_frequency)
|
||||
radio_controller.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
@@ -93,25 +93,25 @@ Passive gate is similar to the regular pump except:
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
|
||||
ui = SSnano.push_open_or_new_ui(user, src, ui_key, ui, "atmos_gas_pump.tmpl", name, 400, 120, 0)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/get_ui_data()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/get_ui_data()
|
||||
var/data = list()
|
||||
data["on"] = on
|
||||
data["pressure_set"] = round(target_pressure*100) //Nano UI can't handle rounded non-integers, apparently.
|
||||
data["max_pressure"] = MAX_OUTPUT_PRESSURE
|
||||
return data
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/atmosinit()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/atmosinit()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
@@ -145,7 +145,7 @@ Passive gate is similar to the regular pump except:
|
||||
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(user as mob)
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/attack_hand(user as mob)
|
||||
if(..())
|
||||
return
|
||||
src.add_fingerprint(usr)
|
||||
@@ -156,7 +156,7 @@ Passive gate is similar to the regular pump except:
|
||||
ui_interact(user)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/Topic(href,href_list)
|
||||
if(..()) return
|
||||
if(href_list["power"])
|
||||
on = !on
|
||||
@@ -173,13 +173,13 @@ Passive gate is similar to the regular pump except:
|
||||
src.updateUsrDialog()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/power_change()
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/power_change()
|
||||
..()
|
||||
update_icon()
|
||||
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob, params)
|
||||
/obj/machinery/atmospherics/components/binary/passive_gate/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob, params)
|
||||
if (!istype(W, /obj/item/weapon/wrench))
|
||||
return ..()
|
||||
if (on)
|
||||
|
||||
Reference in New Issue