/* Passive gate is similar to the regular pump except: * It doesn't require power * Can not transfer low pressure to higher pressure (so it's more like a valve where you can control the flow) * Passes gas when output pressure lower than target pressure */ /obj/machinery/atmospherics/components/binary/passive_gate icon_state = "passgate_map-3" name = "passive gate" desc = "A one-way air valve that does not require power. Passes gas when the output pressure is lower than the target pressure." can_unwrench = TRUE shift_underlay_only = FALSE interaction_flags_machine = INTERACT_MACHINE_OFFLINE | INTERACT_MACHINE_WIRES_IF_OPEN | INTERACT_MACHINE_ALLOW_SILICON | INTERACT_MACHINE_OPEN_SILICON | INTERACT_MACHINE_SET_MACHINE var/target_pressure = ONE_ATMOSPHERE var/frequency = 0 var/id = null var/datum/radio_frequency/radio_connection construction_type = /obj/item/pipe/directional pipe_state = "passivegate" /obj/machinery/atmospherics/components/binary/passive_gate/CtrlClick(mob/user) if(can_interact(user)) on = !on update_icon() return ..() /obj/machinery/atmospherics/components/binary/passive_gate/AltClick(mob/user) if(can_interact(user)) target_pressure = MAX_OUTPUT_PRESSURE update_icon() return ..() /obj/machinery/atmospherics/components/binary/passive_gate/Destroy() SSradio.remove_object(src,frequency) return ..() /obj/machinery/atmospherics/components/binary/passive_gate/update_icon_nopipes() cut_overlays() icon_state = "passgate_off-[set_overlay_offset(piping_layer)]" if(on) add_overlay(getpipeimage(icon, "passgate_on-[set_overlay_offset(piping_layer)]")) /obj/machinery/atmospherics/components/binary/passive_gate/process_atmos() ..() if(!on) return var/datum/gas_mixture/air1 = airs[1] var/datum/gas_mixture/air2 = airs[2] if(air1.release_gas_to(air2, target_pressure)) update_parents() //Radio remote control /obj/machinery/atmospherics/components/binary/passive_gate/proc/set_frequency(new_frequency) SSradio.remove_object(src, frequency) frequency = new_frequency if(frequency) radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA) /obj/machinery/atmospherics/components/binary/passive_gate/proc/broadcast_status() if(!radio_connection) return var/datum/signal/signal = new(list( "tag" = id, "device" = "AGP", "power" = on, "target_output" = target_pressure, "sigtype" = "status" )) radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA) /obj/machinery/atmospherics/components/binary/passive_gate/ui_interact(mob/user, datum/tgui/ui) ui = SStgui.try_update_ui(user, src, ui) if(!ui) ui = new(user, src, "AtmosPump", name) ui.open() /obj/machinery/atmospherics/components/binary/passive_gate/ui_data() var/data = list() data["on"] = on data["pressure"] = round(target_pressure) data["max_pressure"] = round(MAX_OUTPUT_PRESSURE) return data /obj/machinery/atmospherics/components/binary/passive_gate/ui_act(action, params) if(..()) return switch(action) if("power") on = !on investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", INVESTIGATE_ATMOS) investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", INVESTIGATE_SUPERMATTER) // yogs - make supermatter invest useful . = TRUE if("pressure") var/pressure = params["pressure"] if(pressure == "max") pressure = MAX_OUTPUT_PRESSURE . = TRUE else if(pressure == "input") pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null if(!isnull(pressure) || !..()) . = TRUE else if(text2num(pressure) != null) pressure = text2num(pressure) . = TRUE if(.) target_pressure = clamp(pressure, 0, ONE_ATMOSPHERE*100) investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS) investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_SUPERMATTER) // yogs - make supermatter invest useful update_icon() /obj/machinery/atmospherics/components/binary/passive_gate/atmosinit() ..() if(frequency) set_frequency(frequency) /obj/machinery/atmospherics/components/binary/passive_gate/receive_signal(datum/signal/signal) if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command")) return var/old_on = on //for logging if("power" in signal.data) on = text2num(signal.data["power"]) if("power_toggle" in signal.data) on = !on if("set_output_pressure" in signal.data) target_pressure = clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*100) if(on != old_on) investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS) investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_SUPERMATTER) // yogs - make supermatter invest useful if("status" in signal.data) broadcast_status() return broadcast_status() update_icon() /obj/machinery/atmospherics/components/binary/passive_gate/can_unwrench(mob/user) . = ..() if(. && on) to_chat(user, span_warning("You cannot unwrench [src], turn it off first!")) return FALSE /obj/machinery/atmospherics/components/binary/passive_gate/layer2 piping_layer = 2 icon_state = "passgate_map-2" /obj/machinery/atmospherics/components/binary/passive_gate/layer4 piping_layer = 4 icon_state = "passgate_map-4"