//States for airlock_control
#define AIRLOCK_STATE_INOPEN -2
#define AIRLOCK_STATE_PRESSURIZE -1
#define AIRLOCK_STATE_CLOSED 0
#define AIRLOCK_STATE_DEPRESSURIZE 1
#define AIRLOCK_STATE_OUTOPEN 2
datum/computer/file/embedded_program/airlock_controller
var/id_tag
var/exterior_door_tag
var/interior_door_tag
var/airpump_tag
var/sensor_tag
var/sanitize_external
state = AIRLOCK_STATE_CLOSED
var/target_state = AIRLOCK_STATE_CLOSED
var/sensor_pressure = null
receive_signal(datum/signal/signal, receive_method, receive_param)
var/receive_tag = signal.data["tag"]
if(!receive_tag) return
if(receive_tag==sensor_tag)
if(signal.data["pressure"])
sensor_pressure = text2num(signal.data["pressure"])
else if(receive_tag==exterior_door_tag)
memory["exterior_status"] = signal.data["door_status"]
else if(receive_tag==interior_door_tag)
memory["interior_status"] = signal.data["door_status"]
else if(receive_tag==airpump_tag)
if(signal.data["power"])
memory["pump_status"] = signal.data["direction"]
else
memory["pump_status"] = "off"
else if(receive_tag==id_tag)
switch(signal.data["command"])
if("cycle")
if(state < AIRLOCK_STATE_CLOSED)
target_state = AIRLOCK_STATE_OUTOPEN
else
target_state = AIRLOCK_STATE_INOPEN
receive_user_command(command)
switch(command)
if("cycle_closed")
target_state = AIRLOCK_STATE_CLOSED
if("cycle_exterior")
target_state = AIRLOCK_STATE_OUTOPEN
if("cycle_interior")
target_state = AIRLOCK_STATE_INOPEN
if("abort")
target_state = AIRLOCK_STATE_CLOSED
process()
var/process_again = 1
while(process_again)
process_again = 0
switch(state)
if(AIRLOCK_STATE_INOPEN) // state -2
if(target_state > state)
if(memory["interior_status"] == "closed")
state = AIRLOCK_STATE_CLOSED
process_again = 1
else
var/datum/signal/signal = new
signal.data["tag"] = interior_door_tag
signal.data["command"] = "secure_close"
post_signal(signal)
else
if(memory["pump_status"] != "off")
var/datum/signal/signal = new
signal.data = list(
"tag" = airpump_tag,
"power" = 0,
"sigtype"="command"
)
post_signal(signal)
if(AIRLOCK_STATE_PRESSURIZE)
if(target_state < state)
if(sensor_pressure >= ONE_ATMOSPHERE*0.95)
if(memory["interior_status"] == "open")
state = AIRLOCK_STATE_INOPEN
process_again = 1
else
var/datum/signal/signal = new
signal.data["tag"] = interior_door_tag
signal.data["command"] = "secure_open"
post_signal(signal)
else
var/datum/signal/signal = new
signal.data = list(
"tag" = airpump_tag,
"sigtype"="command"
)
if(memory["pump_status"] == "siphon")
signal.data["stabalize"] = 1
else if(memory["pump_status"] != "release")
signal.data["power"] = 1
post_signal(signal)
else if(target_state > state)
state = AIRLOCK_STATE_CLOSED
process_again = 1
if(AIRLOCK_STATE_CLOSED)
if(target_state > state)
if(memory["interior_status"] == "closed")
state = AIRLOCK_STATE_DEPRESSURIZE
process_again = 1
else
var/datum/signal/signal = new
signal.data["tag"] = interior_door_tag
signal.data["command"] = "secure_close"
post_signal(signal)
else if(target_state < state)
if(memory["exterior_status"] == "closed")
state = AIRLOCK_STATE_PRESSURIZE
process_again = 1
else
var/datum/signal/signal = new
signal.data["tag"] = exterior_door_tag
signal.data["command"] = "secure_close"
post_signal(signal)
else
if(memory["pump_status"] != "off")
var/datum/signal/signal = new
signal.data = list(
"tag" = airpump_tag,
"power" = 0,
"sigtype"="command"
)
post_signal(signal)
if(AIRLOCK_STATE_DEPRESSURIZE)
var/target_pressure = ONE_ATMOSPHERE*0.05
if(sanitize_external)
target_pressure = ONE_ATMOSPHERE*0.01
if(sensor_pressure <= target_pressure)
if(target_state > state)
if(memory["exterior_status"] == "open")
state = AIRLOCK_STATE_OUTOPEN
else
var/datum/signal/signal = new
signal.data["tag"] = exterior_door_tag
signal.data["command"] = "secure_open"
post_signal(signal)
else if(target_state < state)
state = AIRLOCK_STATE_CLOSED
process_again = 1
else if((target_state < state) && !sanitize_external)
state = AIRLOCK_STATE_CLOSED
process_again = 1
else
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.data = list(
"tag" = airpump_tag,
"sigtype"="command"
)
if(memory["pump_status"] == "release")
signal.data["purge"] = 1
else if(memory["pump_status"] != "siphon")
signal.data["power"] = 1
post_signal(signal)
if(AIRLOCK_STATE_OUTOPEN) //state 2
if(target_state < state)
if(memory["exterior_status"] == "closed")
if(sanitize_external)
state = AIRLOCK_STATE_DEPRESSURIZE
process_again = 1
else
state = AIRLOCK_STATE_CLOSED
process_again = 1
else
var/datum/signal/signal = new
signal.data["tag"] = exterior_door_tag
signal.data["command"] = "secure_close"
post_signal(signal)
else
if(memory["pump_status"] != "off")
var/datum/signal/signal = new
signal.data = list(
"tag" = airpump_tag,
"power" = 0,
"sigtype"="command"
)
post_signal(signal)
memory["sensor_pressure"] = sensor_pressure
memory["processing"] = state != target_state
//sensor_pressure = null //not sure if we can comment this out. Uncomment in case of problems -rastaf0
return 1
obj/machinery/embedded_controller/radio/airlock_controller
icon = 'icons/obj/airlock_machines.dmi'
icon_state = "airlock_control_standby"
name = "Airlock Console"
density = 0
frequency = 1449
power_channel = ENVIRON
// Setup parameters only
var/id_tag
var/exterior_door_tag
var/interior_door_tag
var/airpump_tag
var/sensor_tag
var/sanitize_external
initialize()
..()
var/datum/computer/file/embedded_program/airlock_controller/new_prog = new
new_prog.id_tag = id_tag
new_prog.exterior_door_tag = exterior_door_tag
new_prog.interior_door_tag = interior_door_tag
new_prog.airpump_tag = airpump_tag
new_prog.sensor_tag = sensor_tag
new_prog.sanitize_external = sanitize_external
new_prog.master = src
program = new_prog
update_icon()
if(on && program)
if(program.memory["processing"])
icon_state = "airlock_control_process"
else
icon_state = "airlock_control_standby"
else
icon_state = "airlock_control_off"
return_text()
var/state_options = null
var/state = 0
var/sensor_pressure = "----"
var/exterior_status = "----"
var/interior_status = "----"
var/pump_status = "----"
if(program)
state = program.state
sensor_pressure = program.memory["sensor_pressure"]
exterior_status = program.memory["exterior_status"]
interior_status = program.memory["interior_status"]
pump_status = program.memory["pump_status"]
switch(state)
if(AIRLOCK_STATE_INOPEN)
state_options = {"<A href='?src=\ref[src];command=cycle_closed'>Close Interior Airlock</A><BR>
<A href='?src=\ref[src];command=cycle_exterior'>Cycle to Exterior Airlock</A><BR>"}
if(AIRLOCK_STATE_PRESSURIZE)
state_options = "<A href='?src=\ref[src];command=abort'>Abort Cycling</A><BR>"
if(AIRLOCK_STATE_CLOSED)
state_options = {"<A href='?src=\ref[src];command=cycle_interior'>Open Interior Airlock</A><BR>
<A href='?src=\ref[src];command=cycle_exterior'>Open Exterior Airlock</A><BR>"}
if(AIRLOCK_STATE_DEPRESSURIZE)
state_options = "<A href='?src=\ref[src];command=abort'>Abort Cycling</A><BR>"
if(AIRLOCK_STATE_OUTOPEN)
state_options = {"<A href='?src=\ref[src];command=cycle_interior'>Cycle to Interior Airlock</A><BR>
<A href='?src=\ref[src];command=cycle_closed'>Close Exterior Airlock</A><BR>"}
var/output = {"<B>Airlock Control Console</B><HR>
[state_options]<HR>
<B>Chamber Pressure:</B> [sensor_pressure] kPa<BR>
<B>Exterior Door: </B> [exterior_status]<BR>
<B>Interior Door: </B> [interior_status]<BR>
<B>Control Pump: </B> [pump_status]<BR>"}
return output