Files
fulpstation/code/ATMOSPHERICS/components/binary_devices/dp_vent_pump.dm
2014-10-14 15:17:07 +02:00

191 lines
5.0 KiB
Plaintext

/obj/machinery/atmospherics/binary/dp_vent_pump
icon = 'icons/obj/atmospherics/unary_devices.dmi' //We reuse the normal vent icons!
icon_state = "dpvent_map"
//node2 is output port
//node1 is input port
name = "dual-port air vent"
desc = "Has a valve and pump attached to it. There are two ports."
level = 1
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
var/on = 0
var/pump_direction = 1 //0 = siphoning, 1 = releasing
var/external_pressure_bound = ONE_ATMOSPHERE
var/input_pressure_min = 0
var/output_pressure_max = 0
var/pressure_checks = 1
//1: Do not pass external_pressure_bound
//2: Do not pass input_pressure_min
//4: Do not pass output_pressure_max
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
name = "large dual-port air vent"
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
..()
air1.volume = 1000
air2.volume = 1000
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon_nopipes()
overlays.Cut()
if(showpipe)
overlays += getpipeimage('icons/obj/atmospherics/unary_devices.dmi', "dpvent_cap")
if(!on || stat & (NOPOWER|BROKEN))
icon_state = "vent_off"
return
if(pump_direction)
icon_state = "vent_out"
else
icon_state = "vent_in"
/obj/machinery/atmospherics/binary/dp_vent_pump/process()
..()
if(!on)
return 0
var/datum/gas_mixture/environment = loc.return_air()
var/environment_pressure = environment.return_pressure()
if(pump_direction) //input -> external
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure))
if(pressure_checks&2)
pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min))
if(pressure_delta > 0)
if(air1.temperature > 0)
var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
loc.assume_air(removed)
air_update_turf()
if(network1)
network1.update = 1
else //external -> output
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound))
if(pressure_checks&4)
pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure()))
if(pressure_delta > 0)
if(environment.temperature > 0)
var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = loc.remove_air(transfer_moles)
air2.merge(removed)
air_update_turf()
if(network2)
network2.update = 1
return 1
//Radio remote control
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency)
radio_controller.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "ADVP",
"power" = on,
"direction" = pump_direction?("release"):("siphon"),
"checks" = pressure_checks,
"input" = input_pressure_min,
"output" = output_pressure_max,
"external" = external_pressure_bound,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/dp_vent_pump/initialize()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_direction" in signal.data)
pump_direction = text2num(signal.data["set_direction"])
if("checks" in signal.data)
pressure_checks = text2num(signal.data["checks"])
if("purge" in signal.data)
pressure_checks &= ~1
pump_direction = 0
if("stabalize" in signal.data)
pressure_checks |= 1
pump_direction = 1
if("set_input_pressure" in signal.data)
input_pressure_min = Clamp(
text2num(signal.data["set_input_pressure"]),
0,
ONE_ATMOSPHERE*50
)
if("set_output_pressure" in signal.data)
output_pressure_max = Clamp(
text2num(signal.data["set_output_pressure"]),
0,
ONE_ATMOSPHERE*50
)
if("set_external_pressure" in signal.data)
external_pressure_bound = Clamp(
text2num(signal.data["set_external_pressure"]),
0,
ONE_ATMOSPHERE*50
)
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
//if(signal.data["tag"])
spawn(2)
broadcast_status()
update_icon()